X-ray cabinet to deliver highly characterized low-dose soft x-ray radiation to biological samples

被引:1
|
作者
Sengupta, Bishwambhar [1 ]
Medlin, Donald [1 ]
Sprunk, Michael [2 ,4 ]
Napolitano, Justin [3 ]
D'Avanzo, Jaclyn [1 ]
Zheng, Xiao Ran [1 ]
Dean, Delphine [3 ]
Takacs, Endre [1 ]
机构
[1] Clemson Univ, Dept Phys & Astron, Clemson, SC 29634 USA
[2] Clemson Univ, Dept Mech Engn, Clemson, SC 29634 USA
[3] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[4] Auburn Univ, Dept Mech Engn, Auburn, AL 36849 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 03期
关键词
COMPUTED-TOMOGRAPHY; SPACE RADIATION; SAFETY;
D O I
10.1063/1.5109233
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have designed, built, and tested a climate-controlled, radiation-shielded incubator cabinet for the purpose of analyzing the effects of low-dose x-ray radiation on biological tissues and cell cultures. Bremsstrahlung x rays incident on exchangeable fluorescence plates produce strong, quasi-monochromatic radiation directed toward a small container of biological samples. The x-ray source, sample, and detector are enclosed in an incubator-maintaining the optimal environment for biological samples to increase longevity to a maximum of 72 h. To demonstrate the capabilities of the setup, an example experiment is presented. Rat vascular smooth muscle cell growth was observed after irradiation with characteristic x rays of iron, copper, and calcium to impart doses of 2 mGy each. Cultures show significant spectrum dependent increases in cell number over controls at 48 h after irradiation. The experiment lends credence to the efficacy of the apparatus and shows promise for future low-dose bio-radiation studies.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Radiation damage in soft X-ray microscopy
    Wang, J.
    Morin, C.
    Li, L.
    Hitchcock, A. P.
    Scholl, A.
    Doran, A.
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2009, 170 (1-3) : 25 - 36
  • [42] SCINTILLATION SPECTROMETRY OF SOFT X-RAY RADIATION
    ALPEROVI.VR
    KOMYAK, NI
    LYSKOVICH, AB
    PENTSAK, GM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1219 - +
  • [43] Polarizing mirrors for soft X-ray radiation
    Grimmer, H
    Zaharko, O
    Mertins, HC
    Schäfers, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 354 - 357
  • [44] X-RAY EXPOSURE AND RADIATION PROTECTION IN X-RAY DIAGNOSTICS
    SCHMIDT, T
    ATOMKERNENERGIE, 1973, 22 (02): : 129 - 133
  • [45] Fukushima radiation dose was equivalent to X-ray
    不详
    NEW SCIENTIST, 2017, 234 (3125) : 19 - 19
  • [46] The use of low dosage X-ray (Lodox/Statscan) in major trauma: Comparison between low dose X-ray and conventional X-ray techniques
    Boffard, Kenneth D.
    Goosen, Jacques
    Plani, Frank
    Degiannis, Elias
    Potgieter, Herman
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06): : 1175 - 1181
  • [47] MONOX -: A new spectrogoniometer for X-ray-UV radiation and soft X-ray radiation
    André, JM
    Avila, A
    Barchewitz, R
    Benbalagh, R
    Delaunay, R
    Druart, D
    Fontaine, MF
    Ringuenet, H
    JOURNAL DE PHYSIQUE IV, 2004, 118 : 173 - 181
  • [48] LOW-DOSE RBE AND Q FOR X-RAY COMPARED TO GAMMA-RAY RADIATIONS
    BOND, VP
    MEINHOLD, CB
    ROSSI, HH
    HEALTH PHYSICS, 1978, 34 (05): : 433 - 438
  • [49] X-ray split and delay system for soft x-ray at LCLS
    Castagna, J. C.
    Murphy, B.
    Bozek, J.
    Berrah, N.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [50] HERMES: a soft X-ray beamline dedicated to X-ray microscopy
    Belkhou, Rachid
    Stanescu, Stefan
    Swaraj, Sufal
    Besson, Adrien
    Ledoux, Milena
    Hajlaoui, Mahdi
    Dalle, Didier
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 968 - 979