Variation of bispectral index under TIVA with propofol in a paediatric population

被引:24
|
作者
Tirel, O. [1 ,3 ]
Wodey, E. [1 ,3 ]
Harris, R. [4 ]
Bansard, J. Y. [1 ,2 ]
Ecoffey, C. [2 ,3 ]
Senhadji, L. [1 ,2 ]
机构
[1] INSERM, U642, F-35000 Rennes, France
[2] Univ Rennes 1, LTSI, F-35000 Rennes, France
[3] CHU Pontchaillou, Serv Danesthesie Reanimat Chirurg 2, F-35000 Rennes, France
[4] Frenchay Hosp, Dept Anaesthesia, Bristol, Avon, England
关键词
anaesthesia; depth; paediatric; anaesthetics i.v; propofol; monitoring; bispectral index;
D O I
10.1093/bja/aem339
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. In this prospective observational study, we aim to explore the relationship between age and bispectral index (BIS) values at different plasma concentrations of propofol. Methods. Fifty children aged from 3 to 15 yr were included. Anaesthesia was induced using a target-controlled infusion of propofol with the Kataria pharmacokinetic model together with a bolus of remifentanil followed by a continuous infusion rate at 0.2 mu g kg(-1) min(-1). Target plasma propofol concentration was initially stabilized to 6 mu g ml(-1) and continued for 6 min. The target was then decreased and stabilized to 4 mu g ml(-1) and then to 2 mu g ml(-1). BIS values, plasma propofol concentration, and EEG were continuously recorded. In order to explore the relationship between variations in propofol concentration and the EEG bispectrum, we used a multiple correspondence analysis (MCA). Results are shown in median (range). Results. We found no statistical difference between BIS values with propofol 6 mu g ml(-1) [23 (12-40)] and 4 mu g ml(-1) [28 (9-67)]. At 2 mu g ml(-1), BIS was significantly different [52 (24-71)], but a significant correlation between the age of children and BIS values was found (r(2)=0.66; P < 0.01). There was little change in children's position between 6 and 4 mu g ml(-1) in the structure model of the MCA. From 4 to 2 mu g ml(-1), the position of children moved only on axis 2. Conclusions. These results showed the difficulty to interpret BIS values because of the absence of significant change for higher plasma propofol concentration variation or because of the link with age for the lower plasma concentration.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 50 条
  • [31] Propofol effective concentration 50 and its relationship to bispectral index
    Irwin, MG
    Hui, TWC
    Milne, SE
    Kenny, GNC
    ANAESTHESIA, 2002, 57 (03) : 242 - 248
  • [32] The use of bispectral index monitors in paediatric intensive care
    Stephen D Playfor
    Critical Care, 9
  • [33] SNAP-index and Bispectral index during induction of anaesthesia propofol and remifentanil
    Schmidt, GN
    Standl, T
    Lankenau, G
    Hellstern, A
    Hipp, C
    Bischoff, P
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2004, 39 (05): : 286 - 291
  • [34] SNAP index and Bispectral index during different states of propofol/remifentanil anaesthesia
    Schmidt, GN
    Bischoff, P
    Standl, T
    Lankenau, G
    Hellstern, A
    Hipp, C
    Schulte am Esch, J
    ANAESTHESIA, 2005, 60 (03) : 228 - 234
  • [35] Patient state index vs bispectral index as measures of the electroencephalographic effects of propofol
    Soehle, M.
    Kuech, M.
    Grube, M.
    Wirz, S.
    Kreuer, S.
    Hoeft, A.
    Bruhn, J.
    Ellerkmann, R. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (02) : 172 - 178
  • [36] Continuous infusion of propofol in calves: bispectral index and hemodynamic effects
    Deschk, Mauricio
    Wagatsuma, Juliana T.
    Araujo, Marcelo A.
    Santos, Guilherme G. F.
    Junior, Sergio S. R.
    Abimussi, Caio J. X.
    Siqueira, Carlos E.
    Motta, Jessica C. L.
    Perri, Silvia H. V.
    Santos, Paulo S. P.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2016, 43 (03) : 309 - 315
  • [37] Comparison of entropy and bispectral index values during propofol induction
    Balci, Canan
    Karabekir, Hamit S.
    Yigit, Muhammet
    NEUROSCIENCES, 2008, 13 (02) : 122 - 126
  • [38] The utility of the bispectral index in procedural sedation with propofol in the emergency department
    Miner, JR
    Biros, MH
    Seigel, T
    Ross, K
    ACADEMIC EMERGENCY MEDICINE, 2005, 12 (03) : 190 - 196
  • [39] Emergence from propofol Anesthesia in a nonagenarian at a bispectral index of 52
    Kakinohana, M
    Nakamura, S
    Miyata, Y
    Sugahara, K
    ANESTHESIA AND ANALGESIA, 2005, 101 (01): : 169 - 170
  • [40] THE BISPECTRAL INDEX IS LINEARLY RELATED TO PROPOFOL BLOOD-CONCENTRATION
    LESLIE, K
    SESSLER, DI
    SCHROEDER, M
    WALTERS, K
    ANESTHESIOLOGY, 1995, 83 (3A) : A194 - A194