Based on Atmospheric Physics and Ecological Principle to Assess the Accuracies of Field CO2/H2O Measurements From Infrared Gas Analyzers in Closed-Path Eddy-Covariance Systems

被引:2
|
作者
Zhou, Xinhua [1 ,2 ,3 ,4 ]
Gao, Tian [1 ,2 ,5 ]
Pang, Yunchao [1 ,2 ,6 ]
Mahan, Hayden [3 ]
Li, Xiufen [2 ,5 ,6 ]
Zheng, Ning [2 ,7 ]
Suyker, Andrew E. [4 ]
Awada, Tala [4 ]
Zhu, Jiaojun [1 ,2 ,5 ]
机构
[1] Chinese Acad Sci, CAS Key Lab Forest Ecol & Management, Inst Appl Ecol, Shenyang, Peoples R China
[2] Chinese Acad Sci, CAS CSI Joint Lab Res & Dev Monitorirg Forest Flu, Inst Appl Ecol, Shenyang, Peoples R China
[3] Campbell Sci Inc, Logan, UT USA
[4] Univ Nebraska, Sch Nat Resources, Lincoln, NE USA
[5] Chinese Acad Sci, Qingyuan Forest CERN, Shenyang, Peoples R China
[6] Shenyang Agr Univ, Dept Agr Meteorol, Shenyang, Peoples R China
[7] Beijing Servirst Technol Ltd, Beijing, Peoples R China
关键词
FLUX MEASUREMENTS; CO2; WATER; UNCERTAINTY; FOREST; HEAT;
D O I
10.1029/2021EA001763
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Field CO2/H2O measurements from infrared gas analyzers in closed-path eddy-covariance systems have wide applications in earth sciences. Knowledge about exactness of these measurements is required to assess measurement applicability. Although the analyzers are specified with uncertainty components (zero drift, gain drift, cross-sensitivities, and precision), exactness for individual measurements is unavailable due to an absence of methodology to comprehend the components as an overall uncertainty. Adopting an advanced definition of accuracy as a range of all measurement uncertainty sources, the specified components are composited into a model formulated for studying analyzers' CO2/H2O accuracy equations. Based on atmospheric physics and environmental parameters, the analyzers are evaluated using the equations for CO2 accuracy (+/- 0.78 mu molCO(2) mol(-1), relatively +/- 0.18%) and H2O accuracy (+/- 0.15 mmolH(2)O mol(-1)). Evaluation shows that precision and cross-sensitivity are minor uncertainties while zero and gain drifts are major uncertainties. Both drifts need adjusting through zero/span procedures during field maintenance. The equations provide rationales to guide and assess the procedures. H2O span needs more attentions under humid conditions. Under freezing conditions while H2O span is impractical, this span is fortunately unnecessary. Under the same conditions, H2O zero drift dominates H2O measurement uncertainty. Therefore, automatic zero becomes a more applicable and necessary tactic. In general cases of atmospheric CO2 background, automatic CO2 zero/span procedures can narrow CO2 accuracy by 36% (+/- 0.74 to +/- 0.47 mu molCO(2) mol(-1)). Automatic/manual H2O zero/span procedures can narrow H2O accuracy by 27% (+/- 0.15 to +/- 0.11 mmolH(2)O mol(-1)). While ensuring system specifications, the procedures guided by equations improve measurement accuracies.
引用
收藏
页数:20
相关论文
共 35 条
  • [11] Measurements of Stable Isotopes in Atmospheric CO2 and H2O by Open-Path Fourier Transform Infrared Spectrometry
    Wang Wei
    Liu Wen-qing
    Zhang Tian-shu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (08) : 2017 - 2023
  • [12] Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H2O and CO2
    Metzger, Stefan
    Burba, George
    Burns, Sean P.
    Blanken, Peter D.
    Li, Jiahong
    Luo, Hongyan
    Zulueta, Rommel C.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (03) : 1341 - 1359
  • [13] Calculating CO2 and H2O eddy covariance fluxes from an enclosed gas analyzer using an instantaneous mixing ratio
    Burba, George
    Schmidt, Andres
    Scott, Russell L.
    Nakai, Taro
    Kathilankal, James
    Fratini, Gerardo
    Hanson, Chad
    Law, Beverly
    McDermitt, Dayle K.
    Eckles, Robert
    Furtaw, Michael
    Velgersdyk, Michael
    GLOBAL CHANGE BIOLOGY, 2012, 18 (01) : 385 - 399
  • [14] AN OPEN PATH, FAST RESPONSE INFRARED-ABSORPTION GAS ANALYZER FOR H2O AND CO2
    AUBLE, DL
    MEYERS, TP
    BOUNDARY-LAYER METEOROLOGY, 1992, 59 (03) : 243 - 256
  • [15] Study of atmospheric CO2 and H2O vapours from measurement data of infrared transparency
    Asatryan, R
    Gevorkyan, H
    Hovhannisyan, H
    Martoyan, G
    Misakyan, M
    Vardanyan, S
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2352 - 2355
  • [16] A long-term (2002 to 2017) record of closed-path and open-path eddy covariance CO2 net ecosystem exchange fluxes from the Siberian Arctic
    Holl, David
    Wille, Christian
    Sachs, Torsten
    Schreiber, Peter
    Runkle, Benjamin R. K.
    Beckebanze, Lutz
    Langer, Moritz
    Boike, Julia
    Pfeiffer, Eva-Maria
    Fedorova, Irina
    Bolshianov, Dimitry Y.
    Grigoriev, Mikhail N.
    Kutzbach, Lars
    EARTH SYSTEM SCIENCE DATA, 2019, 11 (01) : 221 - 240
  • [17] Experimental evaluation of water vapour cross-sensitivity for accurate eddy covariance measurement of CO2 flux using open-path CO2/H2O gas analysers
    Kondo, Fumiyoshi
    Ono, Keisuke
    Mano, Masayoshi
    Miyata, Akira
    Tsukamoto, Osamu
    TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2014, 66
  • [18] Comparison of two closed-path cavity-based spectrometers for measuring air-water CO2 and CH4 fluxes by eddy covariance
    Yang, Mingxi
    Prytherch, John
    Kozlova, Elena
    Yelland, Margaret J.
    Mony, Deepulal Parenkat
    Bell, Thomas G.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (11) : 5509 - 5522
  • [19] Consequences of Incomplete Surface Energy Balance Closure for CO2 Fluxes from Open-Path CO2/H2O Infrared Gas Analysers
    Heping Liu
    James T. Randerson
    Jamie Lindfors
    William J. Massman
    Thomas Foken
    Boundary-Layer Meteorology, 2006, 120 : 65 - 85
  • [20] Consequences of incomplete surface energy balance closure for CO2 fluxes from open-path CO2/H2O infrared gas analysers
    Liu, Heping
    Randerson, James T.
    Lindfors, Jamie
    Massman, William J.
    Foken, Thomas
    BOUNDARY-LAYER METEOROLOGY, 2006, 120 (01) : 65 - 85