Based on Atmospheric Physics and Ecological Principle to Assess the Accuracies of Field CO2/H2O Measurements From Infrared Gas Analyzers in Closed-Path Eddy-Covariance Systems

被引:2
|
作者
Zhou, Xinhua [1 ,2 ,3 ,4 ]
Gao, Tian [1 ,2 ,5 ]
Pang, Yunchao [1 ,2 ,6 ]
Mahan, Hayden [3 ]
Li, Xiufen [2 ,5 ,6 ]
Zheng, Ning [2 ,7 ]
Suyker, Andrew E. [4 ]
Awada, Tala [4 ]
Zhu, Jiaojun [1 ,2 ,5 ]
机构
[1] Chinese Acad Sci, CAS Key Lab Forest Ecol & Management, Inst Appl Ecol, Shenyang, Peoples R China
[2] Chinese Acad Sci, CAS CSI Joint Lab Res & Dev Monitorirg Forest Flu, Inst Appl Ecol, Shenyang, Peoples R China
[3] Campbell Sci Inc, Logan, UT USA
[4] Univ Nebraska, Sch Nat Resources, Lincoln, NE USA
[5] Chinese Acad Sci, Qingyuan Forest CERN, Shenyang, Peoples R China
[6] Shenyang Agr Univ, Dept Agr Meteorol, Shenyang, Peoples R China
[7] Beijing Servirst Technol Ltd, Beijing, Peoples R China
关键词
FLUX MEASUREMENTS; CO2; WATER; UNCERTAINTY; FOREST; HEAT;
D O I
10.1029/2021EA001763
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Field CO2/H2O measurements from infrared gas analyzers in closed-path eddy-covariance systems have wide applications in earth sciences. Knowledge about exactness of these measurements is required to assess measurement applicability. Although the analyzers are specified with uncertainty components (zero drift, gain drift, cross-sensitivities, and precision), exactness for individual measurements is unavailable due to an absence of methodology to comprehend the components as an overall uncertainty. Adopting an advanced definition of accuracy as a range of all measurement uncertainty sources, the specified components are composited into a model formulated for studying analyzers' CO2/H2O accuracy equations. Based on atmospheric physics and environmental parameters, the analyzers are evaluated using the equations for CO2 accuracy (+/- 0.78 mu molCO(2) mol(-1), relatively +/- 0.18%) and H2O accuracy (+/- 0.15 mmolH(2)O mol(-1)). Evaluation shows that precision and cross-sensitivity are minor uncertainties while zero and gain drifts are major uncertainties. Both drifts need adjusting through zero/span procedures during field maintenance. The equations provide rationales to guide and assess the procedures. H2O span needs more attentions under humid conditions. Under freezing conditions while H2O span is impractical, this span is fortunately unnecessary. Under the same conditions, H2O zero drift dominates H2O measurement uncertainty. Therefore, automatic zero becomes a more applicable and necessary tactic. In general cases of atmospheric CO2 background, automatic CO2 zero/span procedures can narrow CO2 accuracy by 36% (+/- 0.74 to +/- 0.47 mu molCO(2) mol(-1)). Automatic/manual H2O zero/span procedures can narrow H2O accuracy by 27% (+/- 0.15 to +/- 0.11 mmolH(2)O mol(-1)). While ensuring system specifications, the procedures guided by equations improve measurement accuracies.
引用
收藏
页数:20
相关论文
共 35 条
  • [1] COMPARISON OF EDDY-COVARIANCE MEASUREMENTS OF CO2 FLUXES BY OPEN-PATH AND CLOSED-PATH CO2 ANALYZERS
    LEUNING, R
    KING, KM
    BOUNDARY-LAYER METEOROLOGY, 1992, 59 (03) : 297 - 311
  • [2] Accuracies of field CO2-H2O data from open-path eddy-covariance flux systems: assessment based on atmospheric physics and biological environment
    Zhou, Xinhua
    Gao, Tian
    Zheng, Ning
    Yang, Bai
    Li, Yanlei
    Yu, Fengyuan
    Awada, Tala
    Zhu, Jiaojun
    GEOSCIENTIFIC INSTRUMENTATION METHODS AND DATA SYSTEMS, 2022, 11 (02) : 335 - 357
  • [3] EDDY-COVARIANCE CO2 FLUX MEASUREMENTS USING OPEN-PATH AND CLOSED-PATH CO2 ANALYZERS - CORRECTIONS FOR ANALYZER WATER-VAPOR SENSITIVITY AND DAMPING OF FLUCTUATIONS IN AIR SAMPLING TUBES
    LEUNING, R
    MONCRIEFF, J
    BOUNDARY-LAYER METEOROLOGY, 1990, 53 (1-2) : 63 - 76
  • [4] A new disjunct eddy-covariance system for BVOC flux measurements - validation on CO2 and H2O fluxes
    Baghi, R.
    Durand, P.
    Jambert, C.
    Jarnot, C.
    Delon, C.
    Serca, D.
    Striebig, N.
    Ferlicoq, M.
    Keravec, P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2012, 5 (12) : 3119 - 3132
  • [5] Novel design of an enclosed CO2/H2O gas analyser for eddy covariance flux measurements
    Burba, G. G.
    Mcdermitt, D. K.
    Anderson, D. J.
    Furtaw, M. D.
    Eckles, R. D.
    TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2010, 62 (05): : 743 - 748
  • [6] Comparison of net CO2 fluxes measured with open- and closed-path infrared gas analyzers in an urban complex environment
    Jarvi, Leena
    Mammarella, Ivan
    Eugster, Werner
    Ibrom, Andreas
    Siivola, Erkki
    Dellwik, Ebba
    Keronen, Petri
    Burba, George
    Vesala, Timo
    BOREAL ENVIRONMENT RESEARCH, 2009, 14 (04): : 499 - 514
  • [7] Comparative CO2 flux measurements by eddy covariance technique using open- and closed-path gas analysers over the equatorial Pacific Ocean
    Kondo, Fumiyoshi
    Tsukamoto, Osamu
    TELLUS SERIES B-CHEMICAL AND PHYSICAL METEOROLOGY, 2012, 64
  • [8] An open path H2O/CO2 gas analyzer for eddy correlation systems:: theory and design
    Kidd, G
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) : 2373 - 2388
  • [9] Evaluation of six process-based forest growth models using eddy-covariance measurements of CO2 and H2O fluxes at six forest sites in Europe
    Kramer, K
    Leinonen, I
    Bartelink, HH
    Berbigier, P
    Borghetti, M
    Bernhofer, C
    Cienciala, E
    Dolman, AJ
    Froer, O
    Gracia, CA
    Granier, A
    Grünwald, T
    Hari, P
    Jans, W
    Kellomäki, S
    Loustau, D
    Magnani, F
    Markkanen, T
    Matteucci, G
    Mohren, GMJ
    Moors, E
    Nissinen, A
    Peltola, H
    Sabaté, S
    Sanchez, A
    Sontag, M
    Valentini, R
    Vesala, T
    GLOBAL CHANGE BIOLOGY, 2002, 8 (03) : 213 - 230
  • [10] Comparison of CO2 and H2O fluxes over grassland vegetations measured by the eddy-covariance technique and by open system chamber
    Balogh, J.
    Nagy, Z.
    Foti, Sz.
    Pinter, K.
    Czobel, Sz.
    Peli, E. R.
    Acosta, M.
    Marek, M. V.
    Csintalan, Zs.
    Tuba, Z.
    PHOTOSYNTHETICA, 2007, 45 (02) : 288 - 292