Influence of different light curing units on the cytotoxicity of various dental composites

被引:41
|
作者
Sigusch, Bernd W.
Volpel, Andrea
Braun, Ingo
Uhl, Alexander
Jandt, Klaus D.
机构
[1] Electro Med Syst SA, CH-1260 Nyon, Switzerland
[2] Univ Jena, Inst Mat Sci & Technol, D-6900 Jena, Germany
关键词
cytotoxicity; dental composites; light-curing;
D O I
10.1016/j.dental.2006.11.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. To evaluate the dependence of the toxicity of various dental composites on the use of high- and low-power light curing units (LCUs). Methods. The composites Filtek Z 250, Durafill VS, Solitaire 2 and Grandio were polymerized using different light densities from three LCUs, namely Heliolux II, Swiss Master Light (SML) and a prototype LED. The toxicity of polymerized samples was tested by exposing them to the cell culture medium up to 28 days. The extracts of the composites were collected daily and used for incubation in human gingival fibroblasts cultures. Results. Slow, low-intensity curing using the LED or the Heliolux II showed similar characteristics for all four composites, regarding the cell viability rate of human gingival fibroblasts. After 1 day of storage suboptimal results could be observed for the SML/Durafill and optimal results for SML/Grandio combination (approximately 100% cell viability). in addition, the composite Solitaire the SML yielded significantly better results than the other LCUs (cell viability, p <= 0.001: SML 60.5%, Heliolux 44.5%, LED 44.2%). Furthermore, the combination of the SML with Z 250 composite showed, after the first day and up to day 28, statistically significantly higher cell viability rates than the combination with the LED or Heliolux II. Significance. This study shows that the combination of a high power LCU with some composites positively influences the HGF cell viability effected by the investigated composite extracts. Moreover, there is further indication that a reduction of composite toxicity is possible if the curing mode is adapted to the used composite. (C) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1342 / 1348
页数:7
相关论文
共 50 条
  • [31] Biological effects of blue light from dental curing units
    Wataha, JC
    Lockwood, PE
    Lewis, JB
    Rueggeberg, FA
    Messer, RLW
    DENTAL MATERIALS, 2004, 20 (02) : 150 - 157
  • [32] Light Intensity of Curing Units in Dental Offices in Zagreb, Croatia
    Matosevic, Danijela
    Panduric, Vlatko
    Jankovic, Bernard
    Knezevic, Alena
    Klaric, Eva
    Tarle, Zrinka
    ACTA STOMATOLOGICA CROATICA, 2011, 45 (01) : 31 - 40
  • [33] The influence of different light-curing modes on microleakage of posterior resin composites
    Marghalani, H.Y. (hmarghalani@kau.edu.sa), 1600, Taylor and Francis Ltd. (28):
  • [34] The influence of different light-curing modes on microleakage of posterior resin composites
    Marghalani, Hanadi Yousif
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2014, 28 (02) : 136 - 150
  • [35] Biocompatibility of different resin composites after polymerization with two light curing units: an immunohistochemical study
    Ipek, Irem
    Unal, Murat
    Koc, Tulay
    EUROPEAN ORAL RESEARCH, 2023, 58 (01) : 22 - 29
  • [36] The effect of different light curing units on Vickers microhardness and degree of conversion of flowable resin composites
    Aung, Swe Zin
    Takagaki, Tomohiro
    Ikeda, Masaomi
    Nozaki, Kosuke
    Burrow, Michael F.
    Abdou, Ahmed
    Nikaido, Toru
    Tagami, Junji
    DENTAL MATERIALS JOURNAL, 2021, 40 (01) : 44 - 51
  • [37] Influence of light intensity from different curing units upon composite temperature rise
    Knezevic, A
    Tarle, Z
    Meniga, A
    Sutalo, J
    Pichler, G
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) : 362 - 367
  • [38] A method for improving the light intensity distribution in dental light-curing units
    Arikawa, Hiroyuki
    Takahashi, Hideo
    Minesaki, Yoshito
    Muraguchi, Kouichi
    Matsuyama, Takashi
    Kanie, Takahito
    Ban, Seiji
    DENTAL MATERIALS JOURNAL, 2011, 30 (02) : 151 - 157
  • [39] Thermal emission by different light-curing units
    Yap, AUJ
    Soh, MS
    OPERATIVE DENTISTRY, 2003, 28 (03) : 260 - 266
  • [40] Wear of resin composites polymerized by conventional halogen light curing and light emitting diodes curing units
    Kim, H
    Park, SH
    Jung, IY
    Jeon, SB
    Lee, KY
    ASBM6: ADVANCED BIOMATERIALS VI, 2005, 288-289 : 645 - 648