The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator

被引:74
|
作者
Nevelos, JE
Ingham, E
Doyle, C
Nevelos, AB
Fisher, J [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Div Microbiol, Leeds LS2 9JT, W Yorkshire, England
[3] Stryker Howmed Osteon, Newbury RG14 5EG, Berks, England
[4] Bradford Royal Infirm, Bradford BD9 6RJ, W Yorkshire, England
关键词
Polymer; Alumina; Steady State; Wear Rate; Anatomical Position;
D O I
10.1023/A:1008970027306
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The wear of "Biolox Forte" alumina ceramic bearing couples has been investigated at two different acetabular cup angles in a physiological hip joint simulator. All cups were set in the anatomical position of 45 degrees inclination in the M/L plane for the first two million cycles and then four of the six cups were re-aligned to 60 degrees for a further three million cycles. A "running-in" wear of 0.14 mm(3) per million cycles was observed for the first million cycles, after which a steady state wear rate of 0.05 mm(3) per million cycles was observed. Increasing the acetabular cup angle to 60 degrees did not significantly affect the wear rate. (C) 2001 Kluwer Academic Publishers.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 50 条
  • [21] Ceramic acetabular cups for total hip replacement part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement
    Bader, R.
    Willmann, Gerd
    Biomedizinische Technik, 44 (7-8): : 212 - 219
  • [22] Ceramic acetabular cups for total hip replacement - Part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement
    Bader, R
    Willmann, G
    BIOMEDIZINISCHE TECHNIK, 1999, 44 (7-8): : 212 - 219
  • [23] Investigation of the wear properties of ceramic total hip prostheses made of alumina and zirconia combination: A hip simulator study
    Ueno, M
    Ikeuchi, K
    BIOCERAMICS 15, 2003, 240-2 : 809 - 812
  • [24] Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator
    Shibo W.
    Shirong G.
    Hongtao L.
    Huang X.
    Journal of Biomimetics, Biomaterials, and Tissue Engineering, 2010, 7 (01): : 7 - 25
  • [25] Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator
    D'Lima, DD
    Hermida, JC
    Chen, PC
    Colwell, CW
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (05) : 761 - 766
  • [26] WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ZIRCONIA FEMORAL HEADS STUDIED WITH A HIP-JOINT SIMULATOR
    SAIKKO, V
    WEAR, 1994, 176 (02) : 207 - 212
  • [27] Influence of Acetabular Cup Rim Design on the Contact Stress During Edge Loading in Ceramic-on-Ceramic Hip Prostheses
    Mak, Mathew
    Jin, Zhongmin
    Fisher, John
    Stewart, Todd D.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (01): : 131 - 136
  • [28] Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
    Williams, Sophie
    Leslie, Ian
    Isaac, Graham
    Jin, Zhongmin
    Ingham, Eileen
    Fisher, John
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 111 - 117
  • [29] Does Pelvic Orientation Influence Wear Measurement of the Acetabular Cup in Total Hip Arthroplasty-An Experimental Study
    Wu, Junzhe
    Taylor, Dominic
    Forst, Raimund
    Seehaus, Frank
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [30] Wear and functional biological activity of wear debris generated from UHMWPE-on-Zirconia ceramic, metal-on-metal, and alumina ceramic-on-ceramic hip prostheses during hip simulator testing
    Tipper, JL
    Matthews, JB
    Ingham, E
    Stewart, TD
    Fisher, J
    Stone, MH
    FRICTION, LUBRICATION, AND WEAR OF ARTIFICIAL JOINTS, 2003, : 7 - 28