Precision studies using the ABI Prism 3100 Genetic Analyzer for forensic DNA analysis

被引:19
|
作者
Sgueglia, JB [1 ]
Geiger, S [1 ]
Davis, J [1 ]
机构
[1] Massachusetts State Police Crime Lab, Sudbury, MA 01776 USA
关键词
DNA; STR; capillary electrophoresis; precision;
D O I
10.1007/s00216-003-1998-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Precision studies using the ABI Prism 3100 Genetic Analyzer have been conducted by performing multiple runs of the AmpFlSTR Identifiler allelic ladder, 9947A kit positive control DNA and the 250-base-pair fragment from the internal size standard (GeneScan LIZ-500). Intra-run and inter-run precision data demonstrates the sizing reproducibility of the 3100 instrument for forensic applications. This precision data is utilized to assist in making allele assignments for outlier and variant alleles (i.e., 'off-ladder' alleles). It also provides a means of addressing systematic variations due to temperature fluctuations, polymer (POP-4) or capillary effects, and associated troubleshooting efforts.
引用
收藏
页码:1247 / 1254
页数:8
相关论文
共 50 条
  • [21] Drug discovery - Analysis of SNPs by capillary electrophoresis - Tutorial: Using the ABI PRISM SNaPshot Multiplex System
    Chansky, K
    Cohen, R
    Wei, D
    GENETIC ENGINEERING NEWS, 2001, 21 (15): : 34 - 34
  • [22] High-throughput quantitation of double-stranded DNA using the ABI Prism 7700 sequence detection system
    Tian, HJ
    Edenberg, HJ
    ANALYTICAL BIOCHEMISTRY, 2004, 326 (02) : 287 - 288
  • [23] Increased throughput for fragment analysis on an ABI PRISM® automated sequencer using a membrane comb and STRand software
    Toonen, RJ
    Hughes, S
    BIOTECHNIQUES, 2001, 31 (06) : 1320 - 1324
  • [24] Usefulness of microchip electrophoresis for the analysis of mitochondrial DNA in forensic and ancient DNA studies
    Alonso, Antonio
    Albarran, Cristina
    Martin, Pablo
    Garcia, Pilar
    Capilla, Javier
    Garcia, Oscar
    de la Rua, Concepcion
    Izaguirre, Neskuts
    Pereira, Filipe
    Pereira, Luisa
    Amorim, Antonio
    Sancho, Manuel
    ELECTROPHORESIS, 2006, 27 (24) : 5101 - 5109
  • [25] Evaluation of two GenePrint™ fluorescent STR multiplex systems in paternity case work using the ABI 310 genetic analyzer
    van Eede, PH
    Stoltenborg, EPM
    de Lange, GG
    PROGRESS IN FORENSIC GENETICS 7, 1998, 1167 : 15 - 17
  • [26] DNA degradation and genetic analysis of empty puparia: Genetic identification limits in forensic entomology
    Mazzanti, Morena
    Alessandrini, Federica
    Tagliabracci, Adriano
    Wells, Jeffrey D.
    Campobasso, Carlo P.
    FORENSIC SCIENCE INTERNATIONAL, 2010, 195 (1-3) : 99 - 102
  • [27] Deletion detection in the angiotensin I-converting enzyme gene using multiplex PCR on the ABI Genetic Analyzer.
    Qu, KZ
    Zarabpouri, F
    Popov, J
    Sferruzza, A
    CLINICAL CHEMISTRY, 2003, 49 (06) : A84 - A84
  • [28] Publications and letters related to the forensic genetic analysis of low amounts of DNA
    Schneider, Peter M.
    Butler, John M.
    Carracedo, Angel
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2011, 5 (01) : 1 - 2
  • [29] Genotyping with a 16-locus STR multiplex using 12-cm plates on an ABI PRISM 377 DNA Sequencer
    Berti, A
    Virgili, A
    Zignale, G
    Serafini, M
    Lago, G
    PROGRESS IN FORENSIC GENETICS 9, 2003, 1239 : 729 - 732
  • [30] Automated infrared DNA analysis system for forensic genetic purposes and genetic diseases (Rett syndrome)
    Biondi, C
    Ricci, U
    Guarducci, S
    Vieri, F
    Gori, F
    Sereni, A
    Lazzerini, V
    Pelagatti, S
    Uzielli, MLG
    PROGRESS IN FORENSIC GENETICS 8, 2000, (1193): : 451 - 453