Providing Graft Tension in ACL Reconstruction with Preservation of the Hamstring Tibial Attachment Site: A Report on the Technique and Clinical Results

被引:0
|
作者
Sever, Gokhan Bulent [1 ]
Cankus, Cenk [2 ]
机构
[1] SANKO Univ Sani Konukoglu Training & Res Hosp, Dept Orthopedia & Travmatol, Gaziantep, Turkey
[2] SANKO Univ Sch Med, Dept Orthopedia & Traumatol, Gaziantep, Turkey
来源
EUROPEAN JOURNAL OF THERAPEUTICS | 2020年 / 26卷 / 01期
关键词
ACL reconstruction; graft tension; hamstring tendon preserving; CRUCIATE LIGAMENT RECONSTRUCTION; TENDON AUTOGRAFT; DETACHMENT; IMPLANT;
D O I
10.5152/EurJTher.2019.19039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Hamstring autograft is the most commonly used graft in the surgical technique for anterior cruciate ligament reconstruction. Different femoral fixation materials can be used in this surgery. This study aimed to share the surgical technique for anatomic single-band anterior cruciate ligament reconstruction, preserving hamstring tibial attachment site and the clinical results. Methods: Total 42 consecutive patients who were operated for anterior cruciate ligament rupture were included in the study. Anatomic single-band anterior cruciate ligament reconstruction was performed for patients without disjointing the hamstring distal attachment site. Patients were evaluated in terms of age, sex, four-arm tendon length, total tunnel length from the hamstring attachment site, femoral tunnel length, length of the graft in the femoral tunnel, and the average tendon length calculated as per the tunnel length. The mean follow-up duration was 17 months. The patients were evaluated clinically using the Tegner activity score, Lysholm score, and International Knee Documentation Scale (IKDC). The anterior translation of the tibia was evaluated with a KT 1000 device. Results: The preoperative and postoperative mean Tegner, IKDC, and Lysholm scores were improved significantly. Conclusion: The surgical method for anatomic single-band anterior cruciate ligament reconstruction with preservation of the hamstring attachment site is a useful technique. Moreover, this technique is cost-effective and did not increase patient morbidity.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 50 条
  • [31] The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part II:: Tibial site
    Kousa, P
    Järvinen, TLN
    Vihavainen, M
    Kannus, P
    Järvinen, M
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (02): : 182 - 188
  • [32] Factors Influencing the Initial Constraint Level of the Knee Joint and Its Effect on Clinical Outcomes After ACL Reconstruction With Hamstring Graft
    Chung, Kwangho
    Choi, Chong Hyuk
    Jung, Min
    Choi, Jeehoon
    Kim, Sung-Jae
    Kim, Sung-Hwan
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (02)
  • [33] Comparison of outside-in and inside-out technique for tibial fixation of a soft-tissue graft in ACL reconstruction using the Shim technique
    Lenschow, S.
    Schliemann, B.
    Schulze, M.
    Raschke, M.
    Koesters, C.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (09) : 1293 - 1299
  • [34] Comparison of outside-in and inside-out technique for tibial fixation of a soft-tissue graft in ACL reconstruction using the Shim technique
    S. Lenschow
    B. Schliemann
    M. Schulze
    M. Raschke
    C. Kösters
    [J]. Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 1293 - 1299
  • [35] Suspensory Versus Interference Tibial Fixation of Hamstring Tendon Autografts in Anterior Cruciate Ligament Reconstruction: Results From the New Zealand ACL Registry
    Rahardja, Richard
    Love, Hamish
    Clatworthy, Mark G.
    Monk, Andrew P.
    Young, Simon W.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (04): : 904 - 911
  • [36] Prospective randomized clinical comparison of femoral transfixation versus bioscrew fixation in hamstring tendon ACL reconstruction - a preliminary report
    Rose, Tim
    Hepp, Pierre
    Venus, Julia
    Stockmar, Christoph
    Josten, Christoph
    Lill, Helmut
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (08) : 730 - 738
  • [37] Prospective randomized clinical comparison of femoral transfixation versus bioscrew fixation in hamstring tendon ACL reconstruction—a preliminary report
    Tim Rose
    Pierre Hepp
    Julia Venus
    Christoph Stockmar
    Christoph Josten
    Helmut Lill
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 730 - 738
  • [38] Isokinetic flexion strength recovery after ACL reconstruction: a comparison between all inside graft-link technique and full tibial tunnel technique
    Monaco, Edoardo
    Redler, Andrea
    Fabbri, Mattia
    Proietti, Lorenzo
    Gaj, Edoardo
    Daggett, Matthew
    Ferretti, Andrea
    [J]. PHYSICIAN AND SPORTSMEDICINE, 2019, 47 (01): : 132 - 135
  • [39] Low-Profile Cortical Screw Tibial Fixation for Hamstring Anterior Cruciate Ligament Reconstruction: Surgical Technique and Stability Results
    Prodromos, Chadwick
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 272 - 273
  • [40] The use of a mono-fluted reamer results in decreased enlargement of the tibial tunnel when using a transtibial ACL reconstruction technique
    Knight, Justin R.
    Condie, Daniel
    Querry, Ross
    Robertson, William J.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (02) : 357 - 362