Correlation between needle behavior and fuel flow rate for gasoline direct injection injector using X-ray phase contrast imaging technique

被引:5
|
作者
Park, Jeonghwan [1 ,2 ]
Lee, Hyunjick [1 ]
Kim, HyungIk [1 ]
Chang, Mengzhao [3 ]
Park, Suhan [4 ]
Park, Sungwook [5 ]
机构
[1] HYUNDAI Kef Corp, Prod Design Team 2, 102 Gosan Ro, Gunpo Si, South Korea
[2] Hanyang Univ, Dept Mech Convergence Engn, Grad Sch, 222 Wangsimni Ro, Seoul 04763, South Korea
[3] Chonnam Natl Univ, Dept Mech Engn, Grad Sch, 120 Neungdong Ro, Seoul 05029, South Korea
[4] Konkuk Univ, Sch Mech & Aerosp Engn, 120 Neungdong Ro, Seoul 05029, South Korea
[5] Hanyang Univ, Sch Mech Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
关键词
Armature bouncing; Gasoline direct injection (GDI); Injection rate; Needle behavior; Shot to shot (STS); X-ray phase contrast imaging (XPCI); EMISSIONS;
D O I
10.1016/j.fuel.2022.125123
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To meet strong emission regulations such as Euro-7, which is expected to be implemented in 2025. The multiple-injection strategy is one of well-known solutions to reduce exhaust gas and improve combustion performance on GDI engine. In order to realize multiple-injection strategy, it is necessary to secure excellent flow rate repeatability within short period. Therefore, the purpose of this study was to analyze the flow rate repeatability of GDI injector under various multiple injection conditions and to correlate with needle behavior of GDI injector and flow rate repeatability. To analyze flow rate repeatability, the injection rate data was obtained by the Bosch method and the individual flow rates of 110 shots were analyzed under several experimental conditions. The movements of the ball and armature inside the injector were visualized using the X-ray phase contrast imaging (XPCI) technique, and the individual behaviors of the ball and the armature were quantitatively analyzed by image post-processing analysis. In this study were used two test GDI injectors with same structure. Whereas Flow rate results were different on shorter dwell time conditions. This study revealed that a specific injector had unstable injection rate and worse Shot to Shot (STS) deviation under dwell time 0.7 ms. In addition, armature bouncing appeared in a specific GDI injector. This armature bouncing affects unstable flow rate characteristics because when armature lift up again, the position of armature was different at every time.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Phase-contrast tomographic imaging using an X-ray interferometer
    Momose, A
    Takeda, T
    Itai, Y
    Yoneyama, A
    Hirano, K
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 309 - 314
  • [22] Phase contrast imaging using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207
  • [23] Phase-contrast X-ray imaging of the gas diffusion layer of fuel cells
    Takeya, S.
    Yoneyama, A.
    Miyamoto, J.
    Gotoh, Y.
    Ueda, K.
    Hyodo, K.
    Takeda, T.
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 813 - 816
  • [24] Characterization of pyrocarbon coated materials using laboratory based x-ray phase contrast imaging technique
    Kashyap, Y. S.
    Roy, Tushar
    Sarkar, P. S.
    Yadav, P. S.
    Shukla, Mayank
    Sinha, Amar
    Dasgupta, K.
    Sathiyamoorthy, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (08):
  • [25] MHz frame rate hard X-ray phase-contrast imaging using synchrotron radiation
    Olbinado, Margie P.
    Just, Xavier
    Gelet, Jean-Louis
    Lhuissier, Pierre
    Scheel, Mario
    Vagovic, Patrik
    Sato, Tokushi
    Graceffa, Rita
    Schulz, Joachim
    Mancuso, Adrian
    Morse, John
    Rack, Alexander
    OPTICS EXPRESS, 2017, 25 (12): : 13857 - 13871
  • [26] Modelling of a novel x-ray phase contrast imaging technique based on coded apertures
    Olivo, A.
    Speller, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (22): : 6555 - 6573
  • [27] Study of spray characteristics based on a line x-ray phase contrast imaging technique
    Liu, Jin-Song
    Qi, Fang
    Xu, Cang-Su
    Neiranji Gongcheng/Chinese Internal Combustion Engine Engineering, 2009, 30 (06): : 82 - 87
  • [28] X-ray imaging of various biological samples using a phase-contrast hard X-ray microscope
    Kim, Guk Bae
    Yoon, Yae Jin
    Shin, Tae Joo
    Youn, Hwa Shik
    Gho, Yong Song
    Lee, Sang Joon
    MICROSCOPY RESEARCH AND TECHNIQUE, 2008, 71 (09) : 639 - 643
  • [29] Wide-area phase-contrast X-ray imaging using large X-ray interferometers
    Momose, A
    Takeda, T
    Yoneyama, A
    Koyama, I
    Itai, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 917 - 920
  • [30] Using measurements of the spatial SNR to optimize phase contrast X-ray imaging
    Ullherr, M.
    Balles, A.
    Fella, C.
    Zabler, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 877 : 44 - 50