Impact of root fillings and posts on the diagnostic ability of three intra-oral digital radiographic systems in detecting vertical root fractures

被引:15
|
作者
Nascimento, H. A. R. [1 ]
Neves, F. S. [1 ]
de-Azevedo-Vaz, S. L. [2 ]
Duque, T. M. [3 ]
Ambrosano, G. M. B. [4 ]
Freitas, D. Q. [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, Brazil
[2] Univ Fed Espirito Santo, Fac Dent, Dept Clin Dent, Vitoria, Spain
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Clin Dent, Div Endodont, Piracicaba, Brazil
[4] Univ Estadual Campinas, Dent Sch Piracicaba, Dept Community Dent, Div Bioestat, Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
diagnostic imaging; digital radiography; root canal filling materials; tooth fractures; BEAM COMPUTED-TOMOGRAPHY; CONVENTIONAL RADIOGRAPHY; RECEPTORS; LESIONS; IMAGES; SENSOR; TEETH; FILM;
D O I
10.1111/iej.12382
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate (i) the accuracy of three intra-oral digital systems in detecting vertical root fractures (VRFs); and (ii) the influence of different intracanal conditions (without filling, filled with Gutta-percha and metal or fibreglass post). Methodology Forty single-rooted human teeth were decoronated and the root canals prepared. VRFs were induced using a universal testing machine on 20 teeth. Radiographic images were obtained using the paralleling technique with three different horizontal angulations on conventional E/F film, two storage phosphor plates (Digora Optime and VistaScan) and one sensor system (SnapShot). All teeth were radiographed with all intracanal conditions tested. All images were evaluated by five examiners. After 30days, 25% of the images were reviewed. Areas under ROC curves, sensitivity, specificity, accuracy, positive predictive and negative predictive values were compared by anova. Results The weighted kappa values for intra- and interobserver reproducibility were 0.48-0.74 and 0.57-0.66, respectively. The sensitivity revealed a significant difference between imaging modalities, with higher values for SnapShot (0.53) and VistaScan (0.46), followed by the film (0.41) and Digora (0.38). The area under the ROC curve for SnapShot (0.82) was greater than for the other systems in the teeth with a fibreglass post (VistaScan: 0.70; Digora: 0.64; film: 0.60). Conclusion All systems gave a similar performance for detecting VRFs; all gave a good performance in the absence of intracanal materials, but performed less well in the presence of a metal post or Gutta-percha. In teeth with a fibreglass post, digital systems with higher resolution should be used.
引用
收藏
页码:864 / 871
页数:8
相关论文
共 14 条
  • [1] Performance evaluation and testing of digital intra-oral radiographic systems
    Doyle, P
    Finney, L
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 313 - 317
  • [2] The influence of number of line pairs in digital intra-oral radiography on the detection accuracy of horizontal root fractures
    Nejaim, Yuri
    Gomes, Amanda Farias
    Nogueira Leal da Silva, Emmanuel Joao
    Groppo, Francisco Carlos
    Haiter Neto, Francisco
    DENTAL TRAUMATOLOGY, 2016, 32 (03) : 180 - 184
  • [3] Evaluation of three imaging techniques for the detection of vertical root fractures in the absence and presence of gutta-percha root fillings
    Khedmat, S.
    Rouhi, N.
    Drage, N.
    Shokouhinejad, N.
    Nekoofar, M. H.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (11) : 1004 - 1009
  • [4] An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolution
    Araki, K
    Endo, A
    Okano, T
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 76 - 80
  • [5] The impact of digital filters on the diagnosis of simulated root resorptions in digital radiographic systems
    Oliveira-Santos, Nicolly
    Gaeta-Araujo, Hugo
    Ruiz, Debora Costa
    Leandro Nascimento, Eduarda Helena
    Cral, Wilson Gustavo
    Oliveira-Santos, Christiano
    Groppo, Francisco Carlos
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (07) : 4743 - 4752
  • [6] The impact of digital filters on the diagnosis of simulated root resorptions in digital radiographic systems
    Nicolly Oliveira-Santos
    Hugo Gaêta-Araujo
    Débora Costa Ruiz
    Eduarda Helena Leandro Nascimento
    Wilson Gustavo Cral
    Christiano Oliveira-Santos
    Francisco Carlos Groppo
    Clinical Oral Investigations, 2022, 26 : 4743 - 4752
  • [7] Effect of delayed scanning on imaging and on the diagnostic accuracy of vertical root fractures in two photostimulable phosphor plates digital systems
    Nascimento, H. A. R.
    Visconti, M. A. P. G.
    Ferreira, L. M.
    Suarez, M. A.
    Haiter Neto, F.
    Freitas, D. Q.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 973 - 979
  • [8] Effect of digital enhancement on the radiographic assessment of vertical root fractures in the presence of different intracanal materials: an in vitro study
    Gaeta-Araujo, Hugo
    Nascimento, Eduarda H. L.
    Oliveira-Santos, Nicolly
    Queiroz, Polyane M.
    Oliveira, Matheus L.
    Freitas, Deborah Q.
    Oliveira-Santos, Christiano
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (01) : 195 - 202
  • [9] Effect of digital enhancement on the radiographic assessment of vertical root fractures in the presence of different intracanal materials: an in vitro study
    Hugo Gaêta-Araujo
    Eduarda H. L. Nascimento
    Nicolly Oliveira-Santos
    Polyane M. Queiroz
    Matheus L. Oliveira
    Deborah Q. Freitas
    Christiano Oliveira-Santos
    Clinical Oral Investigations, 2021, 25 : 195 - 202
  • [10] Impact of Fracture Line Width on Radiographic Diagnosis of Vertical Root Fractures: Analysis of the Generalised Estimating Equation Model
    de Lima, Kaique Leite
    Silva, Lorena Rosa
    Neto, Mozar Andrade Mota
    Cavalcanti, Marcelo Gusmao Paroiso
    Leles, Claudio Rodrigues
    Silva, Maria Alves Garcia Santos
    Estrela, Carlos
    Silva, Brunno Santos de Freitas
    Yamamoto-Silva, Femanda P.
    CHINESE JOURNAL OF DENTAL RESEARCH, 2022, 25 (03): : 197 - 204