Virtual cisternoscopy of intracranial vessels:: A novel visualization technique using virtual reality

被引:18
|
作者
Fellner, F [1 ]
Blank, M [1 ]
Fellner, C [1 ]
Böhm-Jurkovic, H [1 ]
Bautz, W [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Diagnost Radiol, D-91054 Erlangen, Germany
关键词
MR angiography; CT angiography; intracranial vascular malformations; perspective volume rendering; virtual endoscopy; virtual cisternoscopy;
D O I
10.1016/S0730-725X(98)00113-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper introduces a different visualization method which we call "virtual cisternoscopy" using 3D MRA data sets. Virtual cisternoscopy uses well known tools, such as perspective volume rendering (pVR), fly-through techniques, and interactive visualization and combines them to a new approach featuring motion to resolve spatial relationships of intracranial vessels and vascular malformations. With a dedicated flight protocol extraluminal topography of intracranial arteries was analyzed using pVR. For evaluation of difficult vascular malformations extraluminal views are necessary. Therefore, movies of pVR views were produced simulating virtual tracks of neurosurgical flexible endoscopes, by flying around the intracranial vessels and vascular malformations within the cisterns. Endoluminal views were acquired additionally for precise evaluation of cases with complex vessel topography. Two healthy volunteers and three patients were examined. Comparing MIP and pVR images relevant advantages of pVR were found, such as depth information, perspective, lighting, and color. In contrast to MIP and source images of the MRA data set, virtual cisternoscopy of an aneurysm of the left middle cerebral artery demonstrated clearly an early origin of an artery in the region of the aneurysm neck/sac. In this case only virtual cisternoscopy led to the correct therapeutical decision. In a newborn, the type of a vein of Galen aneurysmal malformation could only be evaluated reliably by means of virtual cisternoscopy. The third case of a patient with a clipped aneurysm was evaluated more easily with virtual cisternoscopy than with DSA. In conclusion, virtual cisternoscopy may improve the pretherapeutical visualization of intracranial vascular malformations. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1013 / 1022
页数:10
相关论文
共 50 条
  • [31] Immersive and Collaborative Data Visualization Using Virtual Reality Platforms
    Donalek, Ciro
    Djorgovski, S. G.
    Cioc, Alex
    Wang, Anwell
    Zhang, Jerry
    Lawler, Elizabeth
    Yeh, Stacy
    Mahabal, Ashish
    Graham, Matthew
    Drake, Andrew
    Davidoff, Scott
    Norris, Jeffrey S.
    Longo, Giuseppe
    2014 IEEE INTERNATIONAL CONFERENCE ON BIG DATA (BIG DATA), 2014, : 609 - 614
  • [32] Visualization of crowd contamination simulations using Immersive Virtual Reality
    Teixeira, Vinicius Chrisosthemos
    Silva, Gabriel Fonseca
    Manssour, Isabel H.
    Musse, Soraia H.
    Pinho, Marcio S.
    2024 IEEE 48TH ANNUAL COMPUTERS, SOFTWARE, AND APPLICATIONS CONFERENCE, COMPSAC 2024, 2024, : 1819 - 1824
  • [33] Visualization of Neural Networks in Virtual Reality using UNREAL ENGINE
    Bock, Marcel
    Schreiber, Andreas
    24TH ACM SYMPOSIUM ON VIRTUAL REALITY SOFTWARE AND TECHNOLOGY (VRST 2018), 2018,
  • [34] ObserVAR: Visualization System for Observing Virtual Reality Users using Augmented Reality
    Thanyadit, Santawat
    Punpongsanon, Parinya
    Pong, Ting-Chuen
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY (ISMAR), 2019, : 258 - 268
  • [35] Visualization of Software Architectures in Virtual Reality and Augmented Reality
    Schreiber, Andreas
    Nafeie, Lisa
    Baranowski, Artur
    Seipel, Peter
    Misiak, Martin
    2019 IEEE AEROSPACE CONFERENCE, 2019,
  • [36] Outpace Reality: A Novel Augmented-Walking Technique for Virtual Reality Games
    Cmentowski S.
    Kievelitz F.
    Krueger J.H.
    Proceedings of the ACM on Human-Computer Interaction, 2022, 6
  • [37] Motion protocols for virtual cisternoscopy using volumetric MRA and CTX data
    Blank, M
    Fellner, C
    Fellner, F
    Kalender, WA
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 107 - 111
  • [38] A new simulation technique using virtual reality visualization to optomize beam geometry in prostate cancer IMRT
    Williams, T. R.
    Shang, C.
    Beavis, A.
    Ward, J.
    Sims, C.
    Prest, C.
    Page, L.
    Phillips, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S355 - S355
  • [39] MR diagnosis of vein of Galen aneurysmal malformations using virtual cisternoscopy
    Fellner, F
    Fellner, C
    Böhm-Jurkovic, H
    Blank, M
    Bautz, W
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (05) : 293 - 297
  • [40] Using Virtual Reality
    Ebbesmeyer, Peter
    Grafe, Michael
    Krumm, Holger
    Gehrmann, Peter
    ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, 1999, 94 (09): : 561 - 565