Elemental Composition at Silicone Hydrogel Contact Lens Surfaces

被引:23
|
作者
Rex, Jessica [1 ]
Knowles, Timothy [1 ]
Zhao, Xueying [1 ]
Lemp, Jessie [2 ]
Maissa, Cecile [2 ]
Perry, Scott S. [1 ]
机构
[1] Univ Florida, Mat Sci & Engn, Gainesville, FL 32611 USA
[2] Alcon Res Ltd, Vis Care, Ft Worth, TX USA
关键词
Silicone hydrogel; Contact lenses; X-ray photoelectron spectroscopy; Surface analysis; CONVENTIONAL HYDROGEL; POLYMERS; XPS;
D O I
10.1097/ICL.0000000000000454
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: The outermost surface composition of 11 silicone hydrogel (SiHy) lenses was measured using X-ray photoelectron spectroscopy (XPS) to understand differences in wettability and potential interactions within an ocular environment. The SiHy lenses tested included balafilcon A, lotrafilcon A, lotrafilcon B, senofilcon A, comfilcon A, and somofilcon A reusable 2-week or monthly replacement lenses and delefilcon A, samfilcon A, narafilcon A, stenfilcon A, and somofilcon A daily disposable lenses. Methods: All lenses were soaked for 24 hr in phosphate-buffered saline to remove all packaging solution and dried under vacuum overnight before analysis. X-ray photoelectron spectroscopy measurements were performed at 2 take-off angles, 55 degrees and 75 degrees, to evaluate changes in elemental composition as a function of depth from the surface. Results: Detailed analysis of the XPS data revealed distinct differences in the chemical makeup of the different lens types. For all lenses, carbon, oxygen, and nitrogen were observed in varying quantities. In addition, fluorine was detected at the outermost surface region of comfilcon A (3.4%) and lotrafilcon A and B (<0.5%). The silicon content of the near-surface region analyzed varied among lens types, ranging from a low of 1.6% (lotrafilcon B) to a high of 16.5% (comfilcon A). In most instances, silicon enrichment at the outermost surface was observed, resulting from differences in lens formulation and design. Conclusions: Lenses differed most in their surface silicon concentration, with lotrafilcon B and delefilcon A exhibiting the lowest silicon contents and comfilcon A lens exhibiting the highest. Silicon has hydrophobic properties, which, when found at the surface, may influence the wettability of the contact lenses and their interaction with the tear film and ocular tissues. Higher surface silicon contents have been previously correlated with adverse effects, such as enhanced lipid uptake, thus underscoring the importance of monitoring their presence.
引用
收藏
页码:S221 / S226
页数:6
相关论文
共 50 条
  • [31] Oxygen permeability and water content of silicone hydrogel contact lens materials
    Efron, Nathan
    Morgan, Philip B.
    Cameron, Lan D.
    Brennan, Noel A.
    Goodwin, Marie
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (04) : 328 - 333
  • [32] Uptake and Release Phenomena in Contact Lens Care by Silicone Hydrogel Lenses
    Jones, Lyndon
    Powell, Charles H.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 29 - 36
  • [33] Concurrent Acanthamoeba and Fusarium Keratitis With Silicone Hydrogel Contact Lens Use
    Lee, W. Barry
    Grossniklaus, Hans E.
    Edelhauser, Henry F.
    CORNEA, 2010, 29 (02) : 210 - 213
  • [34] Differences in the Daily Symptoms Associated With the Silicone Hydrogel Contact Lens Wear
    Martin, Raul
    Sanchez, Irene
    de la Roda, Cristina
    de Juan, Victoria
    Rodriguez, Guadalupe
    de Paz, Isabel
    Zalama, Maria
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (01): : 49 - 53
  • [35] Tear lipid composition of hydrogel contact lens wearers
    Maissa, Cecile
    Guillon, Michel
    Girard-Claudon, Karine
    Cooper, Philip
    Optometry and Vision Science, 2000, 77 (12 SUPPL.)
  • [36] Tear lipid composition of hydrogel contact lens wearers
    Maïssa, C
    Guillon, M
    Girard-Claudon, K
    Cooper, P
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 3: BASIC SCIENCE AND CLINICAL RELEVANCE, PTS A & B, 2002, 506 : 935 - 938
  • [37] Risk Factors for Contact Lens-Induced Papillary Conjunctivitis Associated With Silicone Hydrogel Contact Lens Wear
    Tagliaferri, Angela
    Love, Thomas E.
    Szczotka-Flynn, Loretta B.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (03): : 117 - 122
  • [38] The impact of contact lens care regimens on the in vitro wettability of conventional and silicone-hydrogel contact lens materials
    Jones, LW
    Long, J
    Chen, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U864 - U864
  • [39] In vitro evaluation of the dehydration characteristics of silicone-hydrogel and conventional hydrogel contact lens materials
    Univ of Waterloo, Waterloo, Ont, Canada
    Optometry and Vision Science, 2000, 77 (12 SUPPL.)
  • [40] Corneal epithelial cell biocompatibility to silicone hydrogel and conventional hydrogel contact lens packaging solutions
    Gorbet, M. B.
    Tanti, N. C.
    Jones, L.
    Sheardown, H.
    MOLECULAR VISION, 2010, 16 (33): : 272 - 282