Accuracy of toric intraocular lens implantation in cataract and refractive surgery

被引:105
|
作者
Visser, Nienke [1 ]
Berendschot, Tos T. J. M. [1 ]
Bauer, Noel J. C. [1 ]
Jurich, Jessica [2 ]
Kersting, Oliver [2 ]
Nuijts, Rudy M. M. A. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Univ Eye Clin, Maastricht, Netherlands
[2] Sensomotor Instruments GmbH, Teltow, Germany
来源
关键词
ROTATIONAL STABILITY; CORNEAL ASTIGMATISM; CYCLOTORSION; ORIENTATION; ALIGNMENT; INCISIONS; SYSTEM; MYOPIA;
D O I
10.1016/j.jcrs.2011.02.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the accuracy of a commonly used 3-step procedure for toric pseudophakic and phakic intraocular lens (IOL) implantation. SETTING: University Eye Clinic, Maastricht University Medical Centre, Maastricht, The Netherlands. DESIGN: Cohort study. METHOD: In this analysis of toric IOL implantation, 6 preoperative images of the eye per patient and the surgery video were obtained using a digital imaging system. All 3 steps for toric IOL implantation were analyzed as follows: reference axis marking, alignment axis marking, and IOL alignment. In addition, vector analysis was used to calculate the errors in toric IOL alignment. RESULTS: Forty eyes (26 pseudophakic, 14 phakic) were analyzed. The mean errors in reference axis marking, alignment axis marking, and toric IOL alignment were 2.4 degrees +/- 0.8 (SD), 3.3 +/- 2.0 degrees, and 2.6 +/- 2.6 degrees, respectively. Together, these 3 errors led to a mean total error in toric IOL alignment of 4.9 +/- 2.1 degrees. Subgroup analysis showed no significant difference in mean error between pseudophakic IOL and phakic toric IOL alignment (P=.501). Vector analysis showed a mean angle or error of -2 +/- 8 degrees (pseudophakic IOLs) and 6 +/- 14 degrees (phakic IOLs). CONCLUSIONS: A commonly used 3-step ink-marker procedure to implant toric IOLs led to a mean error in IOL placement of approximately 5 degrees. The error was especially relevant in cases in which higher cylinder power IOLs were implanted. Orienting the toric IOL with great accuracy is necessary in all patients to achieve the best cylinder correction.
引用
收藏
页码:1394 / 1402
页数:9
相关论文
共 50 条
  • [41] Subluxated cataract lens surgery using sutured segments or rings and implantation of toric intraocular lenses
    Do, Anna T.
    Holz, Huck A.
    Cionni, Robert J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (03): : 392 - 398
  • [42] Cataract surgery and intraocular lens implantation in children
    Balyeat, HD
    Richard, JM
    Scott, MH
    Weir, KD
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 121 (02) : 226 - 227
  • [43] Cataract surgery and intraocular lens implantation in retinoblastoma
    Shanmugam, MP
    Rao, SK
    Khetan, V
    Kumar, PJR
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09): : 1825 - 1826
  • [44] Correction to: Refractive outcomes of femtosecond laser-assisted cataract surgery with arcuate keratotomy and standard phacoemulsification with toric intraocular lens implantation
    Meng-Yin Lin
    Yun-Dun Shen
    Hsin-Yuan Tan
    I-Jong Wang
    I-Chan Lin
    [J]. International Ophthalmology, 2022, 42 : 2643 - 2643
  • [45] Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation
    Ho Seok Chung
    Jae Lim Chung
    Young Jun Kim
    Hun Lee
    Jae Yong Kim
    Hungwon Tchah
    [J]. Scientific Reports, 11
  • [46] Refractive outcome and patient satisfaction after cataract surgery with mutifocal intraocular lens implantation
    El Kouhen, Nabil
    Mnasri, Heni
    Premy, Shanour
    Mouna, Ali
    Agapie, Adina
    Ferte, Agathe
    Ameloot, Francois
    Perone, Jean-Marc
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [47] Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation
    Chung, Ho Seok
    Chung, Jae Lim
    Kim, Young Jun
    Lee, Hun
    Kim, Jae Yong
    Tchah, Hungwon
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [48] Refractive Changes After Implantation of Reversed Intraocular Lens in Cataract Surgery: A Mathematical Model
    Yang, Hongseok
    Matinrad, Hedieh
    Goldbaum, Michael H.
    Bu, Jennifer J.
    Fukuoka, Hideki
    Afshari, Natalie A.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (05) : 326 - +
  • [49] Astigmatism management in cataract surgery with the AcrySof toric intraocular lens
    Bauer, Noel J. C.
    de Vries, Niels E.
    Webers, Carroll A. B.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1483 - 1488
  • [50] Outcomes of Pseudophakic Toric Intraocular Lens Implantation in Keratoconic Eyes With Cataract
    Nanavaty, Mayank A.
    Lake, Damian B.
    Daya, Sheraz M.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 884 - +