Spectral CT of the Extremities with a Silicon Strip Photon Counting Detector

被引:2
|
作者
Sisniega, A. [1 ]
Zbijewski, W. [1 ]
Stayman, J. W. [1 ]
Xu, J. [1 ]
Taguchi, K. [2 ]
Siewerdsen, J. H. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
photon counting x-ray; spectral CT; cone-beam CT; extremities imaging; statistical reconstruction;
D O I
10.1117/12.2082092
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Photon counting x-ray detectors (PCXDs) are an important emerging technology for spectral imaging and material differentiation with numerous potential applications in diagnostic imaging. We report development of a Si-strip PCXD system originally developed for mammography with potential application to spectral CT of musculoskeletal extremities, including challenges associated with sparse sampling, spectral calibration, and optimization for higher energy x-ray beams. Methods: A bench-top CT system was developed incorporating a Si-strip PCXD, fixed anode x-ray source, and rotational and translational motions to execute complex acquisition trajectories. Trajectories involving rotation and translation combined with iterative reconstruction were investigated, including single and multiple axial scans and longitudinal helical scans. The system was calibrated to provide accurate spectral separation in dual-energy three-material decomposition of soft-tissue, bone, and iodine. Image quality and decomposition accuracy were assessed in experiments using a phantom with pairs of bone and iodine inserts (3, 5, 15 and 20 mm) and an anthropomorphic wrist. Results: The designed trajectories improved the sampling distribution from 56% minimum sampling of voxels to 75%. Use of iterative reconstruction (viz., penalized likelihood with edge preserving regularization) in combination with such trajectories resulted in a very low level of artifacts in images of the wrist. For large bone or iodine inserts (>5 mm diameter), the error in the estimated material concentration was <16% for (50 mg/mL) bone and <8% for (5 mg/mL) iodine with strong regularization. For smaller inserts, errors of 20-40% were observed and motivate improved methods for spectral calibration and optimization of the edge-preserving regularizer. Conclusion: Use of PCXDs for three-material decomposition in joint imaging proved feasible through a combination of rotation-translation acquisition trajectories and iterative reconstruction with optimized regularization.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results in a dynamic phantom
    Holmes, Thomas Wesley
    Yin, Zhye
    Stevens, Grant M.
    Slavic, Scott
    Okerlund, Darin R.
    Maltz, Jonathan S.
    Pourmorteza, Amir
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2023, 17 (05) : 341 - 344
  • [42] Significance of the spectral correction of photon counting detector response in material classification from spectral x-ray CT
    Jumanazarov, Doniyor
    Koo, Jakeoung
    Poulsen, Henning F.
    Olsen, Ulrik L.
    Iovea, Mihai
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (03)
  • [43] The significance of the spectral correction of photon counting detector response in material classification from spectral X-ray CT
    Jumanazarov, Doniyor
    Koo, Jakeoung
    Poulsen, Henning F.
    Olsen, Ulrik L.
    Iovea, Mihai
    QUANTUM OPTICS AND PHOTON COUNTING 2021, 2021, 11771
  • [44] Spectral Inconsistency Analysis on a CdTe Photon-Counting Detector
    Qi, B.
    Gao, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E401 - E401
  • [45] Spectral CT reconstruction with an explicit photon-counting detector model: a "one-step" approach
    Rodesch, Pierre-Antoine
    Rebuffel, V.
    Fournier, C.
    Forbes, F.
    Verger, L.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [46] Spectral photon-counting CT in cardiovascular imaging
    Sandfort, Veit
    Persson, Mats
    Pourmorteza, Amir
    Noel, Peter B.
    Fleischmann, Dominik
    Willemink, Martin J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 218 - 225
  • [47] A photon-counting silicon-strip detector for digital mammography with an ultrafast 0.18-μm CMOS ASIC
    Chen, Han
    Cederstrom, Bjorn
    Xu, Cheng
    Persson, Mats
    Karlsson, Staffan
    Danielsson, Mats
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 749 : 1 - 6
  • [48] Advantages of Photon-Counting Detector CT in Aortic Imaging
    Zanon, Chiara
    Cademartiri, Filippo
    Toniolo, Alessandro
    Bini, Costanza
    Clemente, Alberto
    Colacchio, Elda Chiara
    Cabrelle, Giulio
    Mastro, Florinda
    Antonello, Michele
    Quaia, Emilio
    Pepe, Alessia
    TOMOGRAPHY, 2024, 10 (01) : 1 - 13
  • [49] MSK - Myeloma Diagnostics with Photon-Counting Detector CT
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (11): : 976 - +
  • [50] CT technology: photon-counting detector computed tomography
    Layer, Yannik Christian
    Kravchenko, Dmitrij
    Dell, Tatjana
    Kuetting, Daniel
    RADIOLOGIE, 2023, 63 (07): : 497 - 506