Spectral CT of the Extremities with a Silicon Strip Photon Counting Detector

被引:2
|
作者
Sisniega, A. [1 ]
Zbijewski, W. [1 ]
Stayman, J. W. [1 ]
Xu, J. [1 ]
Taguchi, K. [2 ]
Siewerdsen, J. H. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
photon counting x-ray; spectral CT; cone-beam CT; extremities imaging; statistical reconstruction;
D O I
10.1117/12.2082092
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose: Photon counting x-ray detectors (PCXDs) are an important emerging technology for spectral imaging and material differentiation with numerous potential applications in diagnostic imaging. We report development of a Si-strip PCXD system originally developed for mammography with potential application to spectral CT of musculoskeletal extremities, including challenges associated with sparse sampling, spectral calibration, and optimization for higher energy x-ray beams. Methods: A bench-top CT system was developed incorporating a Si-strip PCXD, fixed anode x-ray source, and rotational and translational motions to execute complex acquisition trajectories. Trajectories involving rotation and translation combined with iterative reconstruction were investigated, including single and multiple axial scans and longitudinal helical scans. The system was calibrated to provide accurate spectral separation in dual-energy three-material decomposition of soft-tissue, bone, and iodine. Image quality and decomposition accuracy were assessed in experiments using a phantom with pairs of bone and iodine inserts (3, 5, 15 and 20 mm) and an anthropomorphic wrist. Results: The designed trajectories improved the sampling distribution from 56% minimum sampling of voxels to 75%. Use of iterative reconstruction (viz., penalized likelihood with edge preserving regularization) in combination with such trajectories resulted in a very low level of artifacts in images of the wrist. For large bone or iodine inserts (>5 mm diameter), the error in the estimated material concentration was <16% for (50 mg/mL) bone and <8% for (5 mg/mL) iodine with strong regularization. For smaller inserts, errors of 20-40% were observed and motivate improved methods for spectral calibration and optimization of the edge-preserving regularizer. Conclusion: Use of PCXDs for three-material decomposition in joint imaging proved feasible through a combination of rotation-translation acquisition trajectories and iterative reconstruction with optimized regularization.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Preliminary evaluation of a silicon strip detector for photon-counting spectral CT
    Xu, Cheng
    Danielsson, Mats
    Karlsson, Staffan
    Svensson, Christer
    Bornefalk, Hans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 45 - 51
  • [2] Energy resolution of a segmented silicon strip detector for photon-counting spectral CT
    Xu, Cheng
    Chen, Han
    Persson, Mats
    Karlsson, Staffan
    Danielsson, Mats
    Svensson, Christer
    Bornefalk, Hans
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 715 : 11 - 17
  • [3] Count rate performance of a silicon-strip detector for photon-counting spectral CT
    Liu, X.
    Gronberg, F.
    Sjolin, M.
    Karlsson, S.
    Danielsson, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 827 : 102 - 106
  • [4] Energy resolution of a photon-counting silicon strip detector
    Fredenberg, Erik
    Lundqvist, Mats
    Cederstrom, Bjorn
    Aslund, Magnus
    Danielsson, Mats
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (01): : 156 - 162
  • [5] A Silicon-Strip Detector for Photon-Counting Spectral CT: Energy Resolution From 40 keV to 120 keV
    Liu, Xuejin
    Bornefalk, Hans
    Chen, Han
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1099 - 1105
  • [6] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6709 - 6727
  • [7] Energy-resolved CT imaging with a photon-counting silicon-strip detector
    Persson, Mats
    Huber, Ben
    Karlsson, Staffan
    Liu, Xuejin
    Chen, Han
    Xu, Cheng
    Yveborg, Moa
    Bornefalk, Hans
    Danielsson, Mats
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] Characterization of a silicon strip detector for photon-counting spectral CT using monoenergetic photons from 40 keV to 120 keV
    Liu, Xuejin
    Bornefalk, Hans
    Chen, Han
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [9] Spectrum Optimization for Photon-Counting CT with a Silicon Detector
    Schmidt, T.
    Gronberg, F.
    Fan, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum
    Liu, Xuejin
    Chen, Han
    Bornefalk, Hans
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 68 - 75