Press-fit bipolar radial head arthroplasty, midterm results

被引:21
|
作者
Kodde, Izaak F. [1 ,2 ]
Heijink, Andras [1 ,2 ]
Kaas, Laurens [1 ]
Mulder, Paul G. H. [3 ]
van Dijk, C. Niek [2 ]
Eygendaal, Denise [1 ]
机构
[1] Amphia Hosp, Dept Orthoped Surg, Breda, Netherlands
[2] Acad Med Ctr, Dept Orthoped Surg, Amsterdam, Netherlands
[3] Amphia Hosp, Breda, Netherlands
关键词
Elbow; fracture; prosthesis; radius; replacement; trauma; RADIOCAPITELLAR STABILITY; ELBOW; PROSTHESIS; FRACTURES; REPLACEMENT; MONOPOLAR; INJURIES; EXCISION; OUTCOMES;
D O I
10.1016/j.jse.2016.02.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Theoretical advantages of bipolar compared with monopolar radial head arthroplasty include better accommodation of radiocapitellar malalignment, reduction of capitellar abrasion, and reduction of stress at the bone-implant interfaces. Our purpose was to report the midterm results of press-fit bipolar radial head arthroplasty. Methods: Thirty patients were treated by press-fit bipolar radial head arthroplasty for acute fracture of the radial head, failed earlier treatment, or post-traumatic sequelae. Three patients were lost to follow-up. Results are presented for the remaining 27 patients. Results: At mean follow-up of 48 months (range, 28-73), there had been 3 (11%) revisions. Two involved conversion to prosthetic radiocapitellar hemiarthroplasty for symptomatic capitellar abrasion; a third involved exchange of the articular component (ie, head) for instability. In all, the stems appeared well fixed. A prosthesis in a subluxed position accounted for the 1 (4%) additional radiologic failure. The average flexion-extension arc was 136 degrees (range, 120 degrees-145 degrees), and the average pronation-supination arc was 138 degrees (range, 70 degrees-180 degrees). According to the Mayo Elbow Performance Score, the combined excellent and good results accounted for 70%. Conclusions: The overall midterm outcome of this series of 30 press-fit bipolar radial head arthroplasties can be considered favorable. Although the revision rate was 11%, the stems were well fixed in all. There was 1 (4%) additional radiologic failure. We suggest considering a press-fit bipolar radial head prosthesis for acute comminuted radial head fractures with limited bone loss of the proximal radius. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1235 / 1242
页数:8
相关论文
共 50 条
  • [41] ASSEMBLING CYLINDRICAL PRESS-FIT JOINTS
    ANDREEV, GY
    [J]. RUSSIAN ENGINEERING JOURNAL, 1972, 52 (07): : 54 - 57
  • [42] Radial Neck Dilatory Remodeling After Radial Head Arthroplasty With an Uncemented, Press Fit, Fully Chemically Etched Stem Design
    Sullivan, Matthew P.
    Firoozabadi, Reza
    Kennedy, Stephen A.
    Agel, Julie
    Magnusson, Eric
    Schiffman, Brett
    Folchert, Matthew
    Beingessner, Daphne
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (09) : 497 - 502
  • [43] Press-fit versus threaded acetabular cups in total hip arthroplasty : Functional and radiological results after five years
    Ellenrieder, Martin
    Bader, Rainer
    Bergschmidt, Philipp
    Mittelmeier, Wolfram
    [J]. ACTA ORTHOPAEDICA BELGICA, 2016, 82 (01): : 60 - 67
  • [44] Ultrasonic Assembly of Press-Fit Joints
    Nigmetzyanov R.I.
    Sundukov S.K.
    Fatyukhin D.S.
    [J]. Russian Engineering Research, 2017, 37 (12) : 1044 - 1047
  • [45] Midterm results with a bipolar radial head prosthesis: Radiographic evidence of loosening at the bone-cement interface
    Popovic, Nebojsa
    Lemaire, Roger
    Georis, Pierre
    Gillet, Philippe
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (11): : 2469 - 2476
  • [46] Value comparison of humeral component press-fit and cemented techniques in reverse shoulder arthroplasty
    Berglund, Derek D.
    Mijic, Dragomir
    Law, Tsun Yee
    Kurowicki, Jennifer
    Rosas, Samuel
    Levy, Jonathan C.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (03) : 496 - 502
  • [47] Survivorship analysis at 15 years of cemented press-fit condylar total knee arthroplasty
    Attar, Fahad G.
    Khaw, Fli-Meng
    Kirk, Lorna M. G.
    Gregg, P. J.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 344 - 349
  • [48] The Utilization of Press-Fit Total Knee Arthroplasty is Not Evenly Distributed: A National Registry Review
    Jabbouri, Sahir S.
    Jones, Brett
    Alemayehu, Gabriel
    Jimenez, Emily
    Mullen, Kyle
    Bernstein, Jenna
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (11) : 495 - 502
  • [49] Stress shielding of the humerus in press-fit anatomic shoulder arthroplasty: review and recommendations for evaluation
    Denard, Patrick J.
    Raiss, Patric
    Gobezie, Reuben
    Edwards, T. Bradley
    Lederman, Evan
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : 1139 - 1147
  • [50] Dynamic trial fitting of the cup in press-fit total hip arthroplasty, a feasibility study
    Hoornenborg, Daniel
    Van Loon, Justin
    De Waard, Sheryl
    Sierevelt, Inger N.
    Opdam, Kim T. M.
    Offs, Gino M. M. J. Kerkh
    Haverkamp, Daniel
    [J]. ACTA ORTHOPAEDICA BELGICA, 2021, 87 (02): : 327 - 331