Single and multiple bonds in (strept)avidin-biotin interactions

被引:65
|
作者
Teulon, Jean-Marie [1 ]
Delcuze, Yannick [1 ]
Odorico, Michael [1 ]
Chen, Shu-wen W. [1 ]
Parot, Pierre [1 ]
Pellequer, Jean-Luc [1 ]
机构
[1] Serv Biochim & Toxicol Nucl, CEA, IBEB, F-30207 Bagnols Sur Ceze, France
关键词
avidin; streptavidin; biotin; single bond; multiple bond; interaction; lifetime; atomic force microscopy (AFM); DYNAMIC FORCE SPECTROSCOPY; STREPTAVIDIN-BIOTIN INTERACTION; LIGAND-RECEPTOR BONDS; ENERGY LANDSCAPE; BINDING-SITE; MOLECULAR-INTERACTIONS; INFINITE AFFINITY; LOADING-RATE; AVIDIN; MICROSCOPY;
D O I
10.1002/jmr.1109
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Thanks to Dynamic Force Spectroscopy (DFS) and developments of massive data analysis tools, such as YieldFinder, Atomic Force Microscopy (AFM) becomes a powerful method for analyzing long lifetime ligand-receptor interactions. We have chosen the well-known system, (strept)avidin-biotin complex, as an experimental model due to the lack of consensus on interpretations of the rupture force spectrum (Walton et al., 2008). We present new measurements of force-displacement curves for the (strept)avidin-biotin complex. These data were analyzed using the YieldFinder software based on the Bell-Evans formalism. In addition, the Williams model was adopted to interpret the bonding state of the system. Our results indicate the presence of at least two energy barriers in two loading rate regimes. Combining with structural analysis, the energy barriers can be interpreted in a novel physico-chemical context as one inner barrier for H-bond ruptures (gamma < 1 angstrom), and one outer barrier for escaping from the binding pocket which is blocked by the side chain of a symmetry-related Trp120 in the streptavidin tetramer. In each loading rate regime, the presence of multiple parallel bonds was implied by the Williams model. Interestingly, we found that in literature different terms created for addressing the apparent discrepancies in the results of avidin-biotin interactions can be reconciled by taking into account multiple parallel bonds. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:490 / 502
页数:13
相关论文
共 50 条
  • [31] Biotin interference in immunoassays based on biotin-strept(avidin) chemistry: An emerging threat
    Luong, John H. T.
    Male, Keith B.
    Glennon, Jeremy D.
    BIOTECHNOLOGY ADVANCES, 2019, 37 (05) : 634 - 641
  • [32] Protein supramolecular complex formation by site-specific avidin-biotin interactions
    Mori, Yutaro
    Wakabayashi, Rie
    Goto, Masahiro
    Kamiya, Noriho
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2013, 11 (06) : 914 - 922
  • [33] DISSOCIATION OF AVIDIN-BIOTIN COMPLEXES BY GUANIDINIUM CHLORIDE
    GREEN, NM
    TOMS, EJ
    BIOCHEMICAL JOURNAL, 1972, 130 (03) : 707 - &
  • [34] METABOLISM, IN RAT, OF BIOTIN INJECTED INTRAPERITONEALLY AS AVIDIN-BIOTIN COMPLEX
    LEE, HM
    WRIGHT, LD
    MCCORMIC.DB
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1973, 142 (02): : 439 - 442
  • [35] USE OF AVIDIN-BIOTIN INTERACTION IN IMMUNOENZYMATIC TECHNIQUES
    GUESDON, JL
    TERNYNCK, T
    AVRAMEAS, S
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (08) : 1131 - 1139
  • [36] Avidin-biotin micropatterning methods for biosensor applications
    Orth, RN
    Clark, TG
    Craighead, HG
    BIOMEDICAL MICRODEVICES, 2003, 5 (01) : 29 - 34
  • [37] APPLICATIONS OF AVIDIN-BIOTIN TECHNOLOGY - LITERATURE SURVEY
    WILCHEK, M
    BAYER, EA
    METHODS IN ENZYMOLOGY, 1990, 184 : 14 - 45
  • [38] Avidin-biotin system for delivery of diagnostic agents
    Sakahara, H
    Saga, T
    ADVANCED DRUG DELIVERY REVIEWS, 1999, 37 (1-3) : 89 - 101
  • [39] Nanopore as a Sensor Based on Avidin-Biotin System
    Lepoitevin, Mathilde
    Bechelany, Mikhael
    Balanzat, Emmanuel
    Janot, Jean-Marc
    Balme, Sebastien
    BIOPHYSICAL JOURNAL, 2016, 110 (03) : 337A - 337A
  • [40] DISSOCIATION OF AVIDIN-BIOTIN COMPLEX IN-VIVO
    WEI, RD
    KOU, DH
    HOO, SL
    EXPERIENTIA, 1971, 27 (04): : 366 - &