Oxidation Stability of Insulating Liquids by Rapid Small Scale Oxidation Test

被引:0
|
作者
Cruze, Ann Pamla [1 ]
Lokesh, K. S. [2 ]
Prakash, R. R. Siva [1 ]
机构
[1] Cent Power Res Inst, Dielect Mat Div, Bengaluru, India
[2] JSS Sci & Technol Univ, Environm Engn, Mysore, Karnataka, India
关键词
Insulating liquids; Oxidation stability; Induction period; Rapid small scale test method;
D O I
10.1109/icdl.2019.8796702
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Insulation materials are an important component of transformers; the life of the electrical equipment depends on the quality of solid and liquid insulating materials used. Mineral insulating oils, synthetic esters and natural esters are different types of liquid insulating materials. During prolonged service in electrical apparatus these oils undergo deterioration, mainly due to continuous oxidation. Hence, the long-term performance of insulating oils depends on the stability to oxidation. This behaviour is usually termed as resistance to the oxidation process or oxidation stability. Oxidation stability test as per test method IEC 61125 and ASTM D2112 are familiar methods to test the oils. According to IEC 61125 (Method C) the insulating oil, is conditioned at 120 degrees C, with copper catalyst and by bubbling zero air over a duration of 48 hours for natural esters, 164 hours for uninhibited oils and synthetic esters, 500 hours for Inhibited oils. Rotating Pressure Vessel Oxidation Test method (RPVOT) as per ASTM D2112 requires copper catalyst and oxygen pressure of 620 kpa is allowed to oxidize the oil sample at 140 degrees C. Zero air bubbling method assesses the oil based on measurement of dissipation factor, acidity and and sludge development for mineral oil and synthetic esters and dissipation factor, acidity and viscosity for natural esters. RPVOT method measures the induction period. Although the IEC 61125 is conventional, it is time consuming and the RPVOT curve for natural esters cannot be distinguished due to the poor stability characteristics of natural esters. This paper presents the results carried out to measure oxidation stability by using a new method named as Rapid Small Scale Oxidation Test (RSSOT) as per ASTM D7545, using petroxy equipment to measure the induction period. Oxidation stability test has been carried out on mineral insulating oils, synthetic esters and natural esters. The results are compared to assess the suitability of the rapid small scale method for evaluating the stability of insulation oils. It is found that the rapid small scale method is suitable to measure the oxidation stability and the results are comparable to the conventional methods. Further, natural ester and synthetic ester was analyzed both with copper catalyst and without catalyst. It was found that presence of copper catalyst accelerates the rate of oxidation of both synthetic ester and natural ester. RSSOT has the advantage of being a rapid method, simple and easy to use, and where only a small quantity of sample is needed, thereby reducing the risks to safety and waste sample disposal problems.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] EFFECT OF OXIDATION ON DIELECTRIC PROPERTIES OF AN INSULATING OIL
    HAKIM, RM
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1972, EI 7 (04): : 185 - &
  • [32] Oxidation at the Subnanometer Scale
    Trinchero, Adriana
    Klacar, Simon
    Paz-Borbon, Lauro Oliver
    Hellman, Anders
    Gronbeck, Henrik
    JOURNAL OF PHYSICAL CHEMISTRY C, 2015, 119 (20): : 10797 - 10803
  • [33] Oxidation at the atomic scale
    Cadavid, Doris
    Cabot, Andreu
    SCIENCE, 2017, 356 (6335) : 245 - 245
  • [34] DISCUSSION ON OXIDATION AND SCALE
    TUCK, CW
    MORAN, VJ
    TYLECOTE, RF
    MELFORD, DA
    WOOD, GC
    EVANS, EL
    HELFORD
    ATKINSON, M
    GOLDSCHMIDT, HJ
    NUTTING, J
    SACHS, K
    ADAMS, AMJ
    JOURNAL OF THE IRON AND STEEL INSTITUTE, 1962, 200 (07): : 547 - &
  • [35] Analysis of changes in the structure of ecological lubricants after the oxidation stability test
    Drabik, Jolanta
    Trzos, Magdalena
    Pawelec, Ewa
    Kozdrach, Rafal
    Wolszczak, Marek
    PRZEMYSL CHEMICZNY, 2019, 98 (12): : 1892 - 1896
  • [36] Evaluation and comparison between oxidation stability test methods for turbine oils
    Pach, M.
    Zobel, H. K.
    Norrby, T.
    OXIDATION AND THE TESTING OF TURBINE OILS, 2008, 1489 : 69 - +
  • [37] DETERMINATION OF OXIDATION STABILITY OF FATS USING AUTOMATIC VERSION OF SWIFT TEST
    PARDUN, H
    KROLL, E
    FETTE SEIFEN ANSTRICHMITTEL VERBUNDEN MIT DER ZEITSCHRIFT DIE ERNAHRUNGSINDUSTRIE, 1971, 73 (11): : 669 - &
  • [38] Ionic liquids breakdown by Fenton oxidation
    Munoz, Macarena
    Dominguez, Carmen M.
    de Pedro, Zahara M.
    Quintanilla, Asuncion
    Casas, Jose A.
    Rodriguez, Juan J.
    CATALYSIS TODAY, 2015, 240 : 16 - 21
  • [39] Quick coker test: A new and rapid engine oil detergency and thermo-oxidation test
    CHEN Ming
    WANG Chengtao School of Mechanical Engineering
    Science China Mathematics, 2001, (S1) : 472 - 477
  • [40] Lignin oxidation and depolymerisation in ionic liquids
    Prado, R.
    Brandt, A.
    Erdocia, X.
    Hallet, J.
    Welton, T.
    Labidi, J.
    GREEN CHEMISTRY, 2016, 18 (03) : 834 - 841