Three-dimensional teleradiology for surveillance following endovascular aortic aneurysm repair:: A feasibility study

被引:5
|
作者
Kaspersen, JH
Aasland, J
Leira, HO
Odegård, A
Nagelhus, B
Storset, G
Lundbom, J
Rosenlund, TT
Tjora, A
Myhre, HO
机构
[1] SINTEF Hlth Res, Trondheim, Norway
[2] Univ Trondheim Hosp, St Olavs Hosp, Dept Surg, Trondheim, Norway
[3] Univ Trondheim Hosp, St Olavs Hosp, Dept Radiol, Trondheim, Norway
[4] Levanger Hosp, Dept Radiol, Levanger, Norway
[5] Molde Hosp, Dept Radiol, Molde, Norway
[6] Norwegian Univ Sci & Technol, Dept Social & Polit Sci, N-7034 Trondheim, Norway
关键词
abdominal aortic aneurysm; stent-graft; endovascular repair; surveillance; computed tomography; teleradiology;
D O I
10.1583/04-1422.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To study the feasibility of 3-dimensional (3D) teleradiology in surveillance of patients treated with stent-grafts for abdominal aortic aneurysm (AAA). Methods: Between April 2002 and November 2003, 8 AAA patients (7 men; median age 73 years, range 62-84) with stent-grafts had follow-up computed tomograms (CT) performed at their local hospital and transmitted without loss across a broadband connection to the university hospital. On both monitors, the radiologists were presented with the complete CT axial dataset, sagittal and coronal reformatted slices, and a 3D volume-rendered reconstruction. The two radiologists were then able to simultaneously perform measurements and real-time manipulations of the axial and 3D pictures, which were discussed over the telephone or using a videoconferencing unit. Patient satisfaction, the radiologists' evaluation of the method, and the potential cost savings were explored. Results: Twelve follow-up CT scans were performed on the 8 patients. The time for transmission over the teleradiological network averaged 5 minutes, and the evaluation required 15 minutes at the university hospital. The overall technical quality of the images was rated as good by the university radiologist. In 11 studies, the stent-grafts were satisfactory, but a type III endoleak was detected in one 5.5-year-old stent-graft. Neither radiologist had a problem identifying the endoleak. Patients had confidence that the examination at the local hospital was of good quality; they all felt that they received good care and were pleased with avoiding travel to the university hospital. From the economic analysis, an annual savings of 40,000 Euros (US$52,304) was projected, mostly due to avoiding hospital stays and outpatient consultations at the university hospital. Conclusions: The experiences from this study are encouraging, but a larger series will be necessary for a thorough evaluation of 3D teleradiology as a surveillance method for aortic stent-graft patients.
引用
收藏
页码:196 / 199
页数:4
相关论文
共 50 条
  • [41] Scrotal necrosis following endovascular abdominal aortic aneurysm repair
    Zhang, Wayne W.
    Chauvapun, Joe P.
    Dosluoglu, Hasan H.
    VASCULAR, 2007, 15 (02) : 113 - 116
  • [42] Aortoenteric fistula following endovascular abdominal aortic aneurysm repair
    White, Alexander B.
    Coffey, Dale D.
    Barzana, Daniel C.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2022, 8 (03): : 438 - 440
  • [43] Management of Postoperative Complications Following Endovascular Aortic Aneurysm Repair
    Qrareya, Mohammad
    Zuhaili, Bara
    SURGICAL CLINICS OF NORTH AMERICA, 2021, 101 (05) : 785 - 798
  • [44] Opioid Consumption Following Endovascular Repair of Abdominal Aortic Aneurysm
    Balceniuk, Mark D.
    Zhao, Peng
    Blegen, Mariah B.
    Ayers, Brian C.
    Calderon, Thais
    Stoner, Michael C.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E129 - E130
  • [45] Explant of aortic stent grafts following endovascular aneurysm repair
    Boyle, E.
    McHugh, S. M.
    Elmallah, A.
    Lynch, M.
    McGuire, D.
    Ahmed, Z.
    Canning, C.
    Colgan, M. P.
    O'Neill, S. M.
    O'Callaghan, A.
    Martin, Z.
    Madhavan, P.
    VASCULAR, 2019, 27 (05) : 487 - 494
  • [46] Patient-Reported Outcomes of Yearly Imaging Surveillance in Patients Following Endovascular Aortic Aneurysm Repair
    Geraedts, A. C. M.
    Mulay, S.
    Terwee, C. B.
    Vahl, A. C.
    Verhagen, H. J. M.
    Unlu, C.
    Ubbink, D. T.
    Koelemay, M. J. W.
    Balm, R.
    ANNALS OF VASCULAR SURGERY, 2022, 82 : 221 - 227
  • [47] Precise treatment of aortic aneurysm by three-dimensional printing and simulation before endovascular intervention
    Yuan, Ding
    Luo, Han
    Yang, Hongliu
    Huang, Bin
    Zhu, Jingqiang
    Zhao, Jichun
    SCIENTIFIC REPORTS, 2017, 7
  • [48] Impact of Statin Following Endovascular Aneurysm Repair in Patients With Abdominal Aortic Aneurysm
    Nanto, Kiyonori
    Iida, Osamu
    Fujita, Masashi
    Masuda, Masaharu
    Okamoto, Shin
    Ishihara, Takayuki
    Shiraki, Tatsuya
    Kanda, Takashi
    Sunaga, Akihiro
    Tsujimura, Takuya
    Okuno, Shota
    Yanaka, Koji
    Matsuda, Yasuhiro
    Ohashi, Takuya
    Tazaki, Junichi
    Uematsu, Masaaki
    CIRCULATION, 2015, 132
  • [49] Precise treatment of aortic aneurysm by three-dimensional printing and simulation before endovascular intervention
    Ding Yuan
    Han Luo
    Hongliu Yang
    Bin Huang
    Jingqiang Zhu
    Jichun Zhao
    Scientific Reports, 7
  • [50] Thrombus distribution and changes in aneurysm size following endovascular aortic aneurysm repair
    Armon, MP
    Yusuf, SW
    Whitaker, SC
    Gregson, RHS
    Wenham, PW
    Hopkinson, BR
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (06) : 472 - 476