Methodological considerations for the 3D measurement of the X-factor and lower trunk movement in golf

被引:34
|
作者
Joyce, Christopher [1 ]
Burnett, Angus [1 ,2 ]
Ball, Kevin [3 ]
机构
[1] Edith Cowan Univ, Sch Exercise Biomed & Hlth Sci, Perth, WA 6027, Australia
[2] Chinese Univ Hong Kong, Dept Sports Sci & Phys Educ, Shatin, Hong Kong, Peoples R China
[3] Victoria Univ, Sch Exercise & Sports Sci, Melbourne, Vic 8001, Australia
关键词
Golf; X-factor; lumbar; summation; methods; JOINT COORDINATE SYSTEM; ISB RECOMMENDATION; VISUAL ESTIMATION; MOTION; SHOULDER; KINEMATICS; ROTATION; RANGE; ELBOW; DEFINITIONS;
D O I
10.1080/14763141.2010.516446
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is believed that increasing the X-factor (movement of the shoulders relative to the hips) during the golf swing can increase ball velocity at impact. Increasing the X-factor may also increase the risk of low back pain. The aim of this study was to provide recommendations for the three-dimensional (3D) measurement of the X-factor and lower trunk movement during the golf swing. This three-part validation study involved; (1) developing and validating models and related algorithms (2) comparing 3D data obtained during static positions representative of the golf swing to visual estimates and (3) comparing 3D data obtained during dynamic golf swings to images gained from high-speed video. Of particular interest were issues related to sequence dependency. After models and algorithms were validated, results from parts two and three of the study supported the conclusion that a lateral bending/flexion-extension/axial rotation (ZYX) order of rotation was deemed to be the most suitable Cardanic sequence to use in the assessment of the X-factor and lower trunk movement in the golf swing. The findings of this study have relevance for further research examining the X-factor its relationship to club head speed and lower trunk movement and low back pain in golf.
引用
收藏
页码:206 / 221
页数:16
相关论文
共 50 条
  • [41] Measurement of Accommodation and Convergence Eye Movement when a Display and 3D Movie Move in the Depth Direction Simultaneously
    Mochiduki, Shinya
    Yokoyama, Yuki
    Sukegawa, Keigo
    Sato, Hiroki
    Suganuma, Miyuki
    Yamada, Mitsuho
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2018, E101A (02): : 488 - 498
  • [42] X-RAY-SCATTERING FACTOR OF 3D METALS - A COMPARISON BETWEEN THEORY AND EXPERIMENT
    MAZZONE, G
    PHYSICAL REVIEW B, 1981, 23 (08): : 3840 - 3844
  • [43] Integrated 3D motion analysis with functional magnetic resonance neuroimaging to identify neural correlates of lower extremity movement
    Anand, Manish
    Diekfuss, Jed A.
    Slutsky-Ganesh, Alexis B.
    Grooms, Dustin R.
    Bonnette, Scott
    Foss, Kim D. Barber
    DiCesare, Christopher A.
    Hunnicutt, Jennifer L.
    Myer, Gregory D.
    JOURNAL OF NEUROSCIENCE METHODS, 2021, 355
  • [44] Modeling and Measurement of 3D Deformation of Scoliotic Spine Using 2D X-ray Images
    Li, Hao
    Leow, Wee Kheng
    Huang, Chao-Hui
    Sen Howe, Tet
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2009, 5702 : 647 - +
  • [45] Reliability of 3D measurement of pelvic and lower limb kinematics during two single leg landing tasks
    Szlachta, Grzegorz
    Gnat, Rafal
    Bialy, Maciej
    BIOMEDICAL HUMAN KINETICS, 2021, 13 (01) : 73 - 80
  • [46] Pilot Validation Study of Inertial Measurement Units and Markerless Methods for 3D Neck and Trunk Kinematics during a Simulated Surgery Task
    Zhang, Ce
    Greve, Christian
    Verkerke, Gijsbertus Jacob
    Roossien, Charlotte Christina
    Houdijk, Han
    Hijmans, Juha M.
    SENSORS, 2022, 22 (21)
  • [47] Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D
    Joel Poling
    Niranjan Desai
    Gregor Fischer
    Christos Georgakis
    Journal of Civil Structural Health Monitoring, 2018, 8 : 331 - 352
  • [48] Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D
    Poling, Joel
    Desai, Niranjan
    Fischer, Gregor
    Georgakis, Christos
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2018, 8 (02) : 331 - 352
  • [49] In situ measurement of 3D contact angle in sand based on X-ray computed tomography
    Schlueter, Steffen
    Blaser, Sebastian R. G. A.
    Benard, Pascal
    Carminati, Andrea
    VADOSE ZONE JOURNAL, 2022, 21 (03)
  • [50] Bioagriculture Outlier Elimination Based on 3D View of X-Y Variance and Leverage Measurement
    Shen, Weizheng
    Kong, Qingming
    Wang, Jianbo
    Ji, Nan
    Su, Zhongbin
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015