The effect of angulation on intravascular ultrasound imaging observed in vascular phantoms

被引:0
|
作者
Geselschap, JH [1 ]
Heilbron, MJ [1 ]
Hussain, FM [1 ]
Daskalakis, TM [1 ]
Wilson, EP [1 ]
Kopchok, GE [1 ]
White, RA [1 ]
机构
[1] Harbor UCLA Med Ctr, Dept Surg, Torrance, CA 90509 USA
来源
JOURNAL OF ENDOVASCULAR SURGERY | 1998年 / 5卷 / 02期
关键词
experimental; noncoaxial alignment; diameter measurements; centering balloon; angle of incidence;
D O I
10.1583/1074-6218(1998)005<0126:TEOAOI>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To quantify the error introduced by noncoaxial intravascular ultrasound (IVUS) imaging and to evaluate the use of a balloon-tipped catheter in compensating for intraluminal angulation and subsequent dimensional inaccuracy. Methods: The effect of noncoaxial IVUS imaging was investigated in both a polyvinyl chloride phantom and an in vitro canine aorta using a calibrated setup to measure angulation off axis. Imaging was performed at increasing angulation (creating an elliptical image) in both phantoms, with the transducer centered and off center. Diameters were compared to the original coaxial diameter, as well as calculated diameters based on specific angles off axis. The percentage change (error) was also calculated at these angles. The measurements were repeated using a balloon-tipped catheter to center the transducer. Results: The measured diameters and percentage changes compared closely with their calculated counterpart. Up to 25 degrees off axis, the apparent increase in diameter measurement was nearly 10%. Angulation from 30 degrees to 70 degrees resulted in an increase of 15% to 192%. Use of the centering balloon reduced the amount of error by 70% to 85% but was limited to angles less than or equal to 25 degrees due to the design of the test apparatus. Conclusions: The error introduced by noncoaxial IVUS imaging can be significant and may be partially corrected by the use of a centering balloon. Further studies in the clinical application of a centering device are warranted.
引用
收藏
页码:126 / 133
页数:8
相关论文
共 50 条
  • [21] Capacitive micromachined ultrasound transducers for intravascular ultrasound imaging
    Jiaqi Wang
    Zhou Zheng
    Jasmine Chan
    John T. W. Yeow
    Microsystems & Nanoengineering, 6
  • [22] Intravascular ultrasound imaging in coronary angioplasty
    Mudra, H
    INTERNIST, 1997, 38 (01): : 56 - 63
  • [23] Transducer for harmonic intravascular ultrasound imaging
    Vos, HJ
    Frijlink, ME
    Droog, E
    Goertz, DE
    Blacquière, G
    Gisolf, A
    de Jong, N
    van der Steen, AFW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) : 2418 - 2422
  • [24] The current status of intravascular ultrasound imaging
    不详
    CURRENT PROBLEMS IN CARDIOLOGY, 1999, 24 (09) : 547 - 616
  • [25] Clinical Indications for Intravascular Ultrasound Imaging
    Bourantas, Christos V.
    Naka, Katerina K.
    Garg, Scot
    Thackray, Simon
    Papadopoulos, Dimitris
    Alamgir, Farqad M.
    Hoye, Angela
    Michalis, Lampros K.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (10): : 1282 - 1290
  • [26] Capacitive micromachined ultrasound transducers for intravascular ultrasound imaging
    Wang, Jiaqi
    Zheng, Zhou
    Chan, Jasmine
    Yeow, John T. W.
    MICROSYSTEMS & NANOENGINEERING, 2020, 6 (01)
  • [27] INTRAVASCULAR CORONARY ULTRASOUND IMAGING, IS IT USEFUL
    LEE, DY
    EIGLER, N
    LUO, H
    STEFFEN, W
    TABAK, S
    SIEGEL, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A241 - A241
  • [28] INTRAVASCULAR ULTRASOUND IMAGING - A CURRENT PERSPECTIVE
    COY, KM
    MAURER, G
    SIEGEL, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) : 1811 - 1823
  • [29] Imaging of coronary atherosclerosis: intravascular ultrasound
    Garcia-Garcia, Hector M.
    Costa, Marco A.
    Serruys, Patrick W.
    EUROPEAN HEART JOURNAL, 2010, 31 (20) : 2456 - 2469C
  • [30] CLINICAL UTILITY OF INTRAVASCULAR ULTRASOUND IMAGING
    TOBIS, JM
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (03): : 221 - 223