Ratiometric Two-Photon Fluorescent Probe for in Vivo Hydrogen Polysulfides Detection and Imaging during Lipopolysaccharide-Induced Acute Organs Injury

被引:93
|
作者
Zhang, Jing [1 ]
Zhu, Xiao-Yan [1 ]
Hu, Xiao-Xiao [1 ]
Liu, Hong-Wen [1 ]
Li, Jin [1 ]
Feng, Li-Li [1 ]
Yin, Xia [1 ]
Zhang, Xiao-Bing [1 ]
Tan, Weihong [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Collaborat Innovat Ctr Chem & Mol Med, Mol Sci & Biomed Lab,Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ACUTE LUNG INJURY; ACUTE KIDNEY INJURY; BIOIMAGING APPLICATIONS; LIVING CELLS; SUPEROXIDE ANION; RATIONAL DESIGN; LIVER-INJURY; METAL-IONS; MICE; SEPSIS;
D O I
10.1021/acs.analchem.6b03702
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acute organ injury observed during sepsis, caused by an uncontrolled release of inflammatory mediators, such as lipopolysaccharide (LPS), is quite fatal. The development of efficient methods for early diagnosis of sepsis and LPS-induced acute organ injury in living systems is of great biomedical importance. In living systems, cystathionine gamma-lyase (CSE) can be overexpressed due to LPS, and H2Sn can be formed by CSE-mediated cysteine metabolism. Thus, acute organ injury during sepsis may be correlated with H2Sn levels, making accurate detection of H2Sn in living systems of great physiological and pathological significance. In this work, our previously reported fluorescent platform was employed to design and synthesize a FRET-based ratiometric two-photon (TP) fluorescent probe TPR-S, producing a large emission shift in the presence of H2Sn. In this work, a naphthalene derivative two-photon fluorophore was chosen as the energy donor; a rhodol derivative fluorophore served as the acceptor. The 2-fluoro-5-nitrobenzoate group of probe TPR-S reacted with H2Sn and was selectively removed to release the fluorophore, resulting in a fluorescent signal decrease at 448 nm and enhancement at H2Sn nm. The ratio value of the fluorescence intensity between 541 and 448 nm (I-541 nm/I-448 nm) varied from 0.13 to 8.12 (similar to 62-fold), with the H2Sn concentration changing from 0 to 1 mM. The detection limit of the probe was 0.7 mu M. Moreover, the probe was applied for imaging H2Sn, in living cells, tissues, and organs of LPS-induced acute organ injury, which demonstrated its practical application in complex biosystems as a potential method to achieve early diagnosis of LPS-induced acute organ injury.
引用
收藏
页码:11892 / 11899
页数:8
相关论文
共 50 条
  • [41] A two-photon fluorescent probe for ratiometric imaging of hydrogen peroxide in live tissue (vol 47, pg 9618, 2011)
    Chung, Chul
    Srikun, Duangkhae
    Lim, Chang Su
    Chang, Christopher J.
    Cho, Bong Rae
    CHEMICAL COMMUNICATIONS, 2011, 47 (48) : 12893 - 12893
  • [42] Ultrasensitive and ratiometric two-photon fluorescence imaging of Golgi polarity during drug-induced acute kidney injury
    Wang, Hui
    Dong, Mingyan
    Wang, Hongtong
    Huang, Fang
    Li, Ping
    Zhang, Wei
    Zhang, Wen
    Tang, Bo
    CHEMICAL COMMUNICATIONS, 2021, 57 (47) : 5838 - 5841
  • [43] Photostable Ratiometric Two-Photon Fluorescent Probe for Visualizing Hydrogen Polysulfide in Mitochondria and Its Application
    Han, Qingxin
    Ru, Jiaxi
    Wang, Xuechuan
    Dong, Zhe
    Wang, Li
    Jiang, Huie
    Liu, Weisheng
    ACS APPLIED BIO MATERIALS, 2019, 2 (05) : 1987 - 1997
  • [44] A two-photon ratiometric fluorescent probe for the synergistic detection of the mitochondrial SO2/HClO crosstalk in cells and in vivo
    Dou, Kun
    Chen, Guang
    Yu, Fabiao
    Sun, Zhiwei
    Li, Guoliang
    Zhao, Xianen
    Chen, Lingxin
    You, Jinmao
    JOURNAL OF MATERIALS CHEMISTRY B, 2017, 5 (42) : 8389 - 8398
  • [45] A copper(I)-ion selective two-photon fluorescent probe for in vivo imaging
    Lim, Chang Su
    Han, Ji Hee
    Kim, Chang Woo
    Kang, Min Young
    Kang, Dong Won
    Cho, Bong Rae
    CHEMICAL COMMUNICATIONS, 2011, 47 (25) : 7146 - 7148
  • [46] Sodium-Ion-Selective Two-Photon Fluorescent Probe for In Vivo Imaging
    Kim, Mi Kyung
    Lim, Chang Su
    Hong, Jong Tae
    Han, Ji Hee
    Jang, Hye-Young
    Kim, Hwan Myung
    Cho, Bong Rae
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (02) : 364 - 367
  • [47] Fast response and highly selective detection of hydrogen sulfide with a ratiometric two-photon fluorescent probe and its application for bioimaging
    Yang, Guangxin
    Zhang, Jing
    Zhu, Shaojun
    Wang, Yan
    Feng, Xiaowen
    Yan, Mei
    Yu, Jinghua
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 261 : 51 - 57
  • [48] A quadrupolar two-photon fluorescent probe for in vivo imaging of amyloid-β plaques
    Heo, Cheol Ho
    Sarkar, Avik Ranjan
    Baik, Sung Hoon
    Jung, Tae Sung
    Kim, Jeong Jin
    Kang, Hyuk
    Mook-Jung, Inhee
    Kim, Hwan Myung
    CHEMICAL SCIENCE, 2016, 7 (07) : 4600 - 4606
  • [49] A two-photon fluorescent probe for ratiometric imaging of endogenous hypochlorous acid in live cells and tissues
    Jun, Yong Woong
    Sarkar, Sourav
    Singha, Subhankar
    Reo, Ye Jin
    Kim, Hye Rim
    Kim, Jong-Jin
    Chang, Young-Tae
    Ahn, Kyo Han
    CHEMICAL COMMUNICATIONS, 2017, 53 (78) : 10800 - 10803
  • [50] Achieving the ratiometric imaging of steroid sulfatase in living cells and tissues with a two-photon fluorescent probe
    Li, Wei
    Yin, Shulu
    Gong, Xiangyang
    Xu, Wang
    Yang, Ronghua
    Wan, Yichao
    Yuan, Lin
    Zhang, XiaoBing
    CHEMICAL COMMUNICATIONS, 2020, 56 (09) : 1349 - 1352