Ratiometric Two-Photon Fluorescent Probe for in Vivo Hydrogen Polysulfides Detection and Imaging during Lipopolysaccharide-Induced Acute Organs Injury

被引:93
|
作者
Zhang, Jing [1 ]
Zhu, Xiao-Yan [1 ]
Hu, Xiao-Xiao [1 ]
Liu, Hong-Wen [1 ]
Li, Jin [1 ]
Feng, Li-Li [1 ]
Yin, Xia [1 ]
Zhang, Xiao-Bing [1 ]
Tan, Weihong [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Collaborat Innovat Ctr Chem & Mol Med, Mol Sci & Biomed Lab,Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ACUTE LUNG INJURY; ACUTE KIDNEY INJURY; BIOIMAGING APPLICATIONS; LIVING CELLS; SUPEROXIDE ANION; RATIONAL DESIGN; LIVER-INJURY; METAL-IONS; MICE; SEPSIS;
D O I
10.1021/acs.analchem.6b03702
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Acute organ injury observed during sepsis, caused by an uncontrolled release of inflammatory mediators, such as lipopolysaccharide (LPS), is quite fatal. The development of efficient methods for early diagnosis of sepsis and LPS-induced acute organ injury in living systems is of great biomedical importance. In living systems, cystathionine gamma-lyase (CSE) can be overexpressed due to LPS, and H2Sn can be formed by CSE-mediated cysteine metabolism. Thus, acute organ injury during sepsis may be correlated with H2Sn levels, making accurate detection of H2Sn in living systems of great physiological and pathological significance. In this work, our previously reported fluorescent platform was employed to design and synthesize a FRET-based ratiometric two-photon (TP) fluorescent probe TPR-S, producing a large emission shift in the presence of H2Sn. In this work, a naphthalene derivative two-photon fluorophore was chosen as the energy donor; a rhodol derivative fluorophore served as the acceptor. The 2-fluoro-5-nitrobenzoate group of probe TPR-S reacted with H2Sn and was selectively removed to release the fluorophore, resulting in a fluorescent signal decrease at 448 nm and enhancement at H2Sn nm. The ratio value of the fluorescence intensity between 541 and 448 nm (I-541 nm/I-448 nm) varied from 0.13 to 8.12 (similar to 62-fold), with the H2Sn concentration changing from 0 to 1 mM. The detection limit of the probe was 0.7 mu M. Moreover, the probe was applied for imaging H2Sn, in living cells, tissues, and organs of LPS-induced acute organ injury, which demonstrated its practical application in complex biosystems as a potential method to achieve early diagnosis of LPS-induced acute organ injury.
引用
收藏
页码:11892 / 11899
页数:8
相关论文
共 50 条
  • [1] Ratiometric two-photon fluorescent probe for imaging hydrogen peroxide during stroke-induced ferroptosis
    Jian, Zhihong
    Ye, Yingze
    Yu, Kai
    Hu, Wei
    Zhu, Hua
    Wang, Jin
    Xiong, Xiaoxing
    Li, Chunya
    Gu, Lijuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 417
  • [2] A ratiometric two-photon fluorescent probe for imaging hydrogen sulfide in lysosomes
    Feng, Wenqi
    Mao, Zhiqiang
    Liu, Lingzhi
    Liu, Zhihong
    TALANTA, 2017, 167 : 134 - 142
  • [3] Development of a ratiometric two-photon fluorescent probe for imaging of hydrogen peroxide in ischemic brain injury
    Zhai, Baoping
    Hu, Wei
    Hao, Ruilin
    Ni, Wenjing
    Liu, Zhihong
    ANALYST, 2019, 144 (20) : 5965 - 5970
  • [4] Rational design of a lysosomal-targeted ratiometric two-photon fluorescent probe for imaging hydrogen polysulfides in live cells
    Han, Qingxin
    Liu, Xuan
    Wang, Xuechuan
    Yin, Ruojun
    Jiang, Huie
    Ru, Jiaxi
    Liu, Weisheng
    Dyes and Pigments, 2020, 173
  • [5] Rational design of a lysosomal-targeted ratiometric two-photon fluorescent probe for imaging hydrogen polysulfides in live cells
    Han, Qingxin
    Liu, Xuan
    Wang, Xuechuan
    Yin, Ruojun
    Jiang, Huie
    Ru, Jiaxi
    Liu, Weisheng
    DYES AND PIGMENTS, 2020, 173
  • [6] A ratiometric and two-photon fluorescent probe for imaging hydrogen peroxide in living cells
    Wang, Shuoshuo
    Yao, Jipeng
    Wang, Bei
    Liu, Xiang
    LUMINESCENCE, 2022, 37 (06) : 1037 - 1043
  • [7] A two-photon fluorescent probe for ratiometric imaging of hydrogen peroxide in live tissue
    Chung, Chul
    Srikun, Duangkhae
    Lim, Chang Su
    Chang, Christopher J.
    Cho, Bong Rae
    CHEMICAL COMMUNICATIONS, 2011, 47 (34) : 9618 - 9620
  • [8] A ratiometric fluorescent probe for single and two-photon bioimaging of hydrogen peroxide in vitro and in vivo
    Feng, Zhongjiao
    Wu, Jiasheng
    Liu, Weimin
    Ren, Haohui
    Zheng, Xiuli
    Zhang, Wenjun
    Lee, Chun-Sing
    Wang, Pengfei
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 384
  • [9] Ratiometric Two-Photon Fluorescent Probe for Detecting and Imaging Hypochlorite
    Pak, Yen Leng
    Park, Sang Jun
    Xu, Qingling
    Kim, Hwan Myung
    Yoon, Juyoung
    ANALYTICAL CHEMISTRY, 2018, 90 (15) : 9510 - 9514
  • [10] Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
    Lim, Chang Su
    Masanta, Goutam
    Kim, Hyung Joong
    Han, Ji Hee
    Kim, Hwan Myung
    Cho, Bong Rae
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (29) : 11132 - 11135