In vitro validation of new Fourier-domain optical coherence tomography

被引:39
|
作者
Tahara, Satoko [1 ,2 ]
Bezerra, Hiram G. [1 ,2 ]
Baibars, Motaz [1 ,2 ]
Kyono, Hiroyuki [1 ,2 ]
Wang, Wei [1 ,2 ]
Pokras, Stan [1 ,2 ]
Mehanna, Emile [1 ,2 ]
Petersen, Christopher L. [3 ]
Costa, Marco A. [1 ,2 ]
机构
[1] Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
[3] LightLab Imaging, Westford, MA USA
关键词
Fourier-domain optical coherence tomography; validation study; phantom model; INTRAVASCULAR ULTRASOUND; ELUTING STENTS; COVERAGE; APPOSITION;
D O I
10.4244/EIJV6I7A149
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To validate the accuracy and evaluate the intra- and inter-observer variability of vascular measurements using novel Fourier-domain optical coherence tomography (FD-OCT) versus intravascular ultrasound (IVUS) in a coronary phantom model. Methods and results: A dedicated cylindrical phantom comprised of four sections with differing dimensions was used to compare images generated by five FD-OCT and five IVUS catheters. Each FD-OCT catheter was tested using three different consoles, generating 15 imaging pullbacks. Two independent experts, blinded to the phantom data, performed measurements. There were 180 FD-OCT and 60 IVUS cross-sectional measurements of mean lumen diameter (MeanLD), minimal lumen diameter (MLD), maximum lumen diameter (MaxLD) and lumen area (LA) at three points in each section. FD-OCT measurements had excellent correlations with IVUS (concordance correlation coefficient [CCC]: >= 0.9769 for MeanLD, LA or longitudinal length [LL]) and phantom dimensions (CCCs for FD-OCT: >= 0.9958 for MeanLD, LA or LL). FD-OCT measurements were larger than IVUS (p<0.0001), but showed less measurement errors compared to IVUS (p<0.0001). Moreover, FD-OCT caused less discrepancy between MaxLD and MLD versus IVUS (p<0.0001). Intra- and inter-observer variability was low for both FD-OCT (CCCs for MeanLD, LA and LL >= 0.9996) and IVUS (>= 0.9935). Image catheter position did not influence FD-OCT measurements. Conclusions: FD-OCT was more accurate than IVUS and had similar high reproducibility to determine vascular dimensions in vitro. These results support the use of FD-OCT in the clinical setting.
引用
收藏
页码:875 / 882
页数:8
相关论文
共 50 条
  • [41] Fourier-domain optical coherence tomography: recent advances toward clinical utility
    Bouma, Brett E.
    Yun, Seok-Hyun
    Vakoc, Benjamin J.
    Suter, Melissa J.
    Tearney, Guillermo J.
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 2009, 20 (01) : 111 - 118
  • [42] In-focus Fourier-domain Optical Coherence Tomography by Complex Numerical Method
    Yoshiaki Yasuno
    Yusuke Sando
    Jun-ichiro Sugisaka
    Takashi Endo
    Shuichi Makita
    Gouki Aoki
    Masahide Itoh
    Toyohiko Yatagai
    [J]. Optical and Quantum Electronics, 2005, 37 : 1185 - 1189
  • [43] Fourier-Domain Optical Coherence Tomography Imaging in Keratoconus A Corneal Structural Classification
    Sandali, Otman
    El Sanharawi, Mohamed
    Temstet, Cyril
    Hamiche, Taous
    Galan, Alice
    Ghouali, Wajdene
    Goemaere, Isabelle
    Basli, Elena
    Borderie, Vincent
    Laroche, Laurent
    [J]. OPHTHALMOLOGY, 2013, 120 (12) : 2403 - 2412
  • [44] High resolution Fourier-domain optical coherence tomography of retinal angiomatous proliferation
    Truong, Steven N.
    Alam, Suhail
    Zawadzki, Robert J.
    Choi, Stacey S.
    Telander, David G.
    Park, Susanna S.
    Werner, John S.
    Morse, Lawrence S.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (07): : 915 - 925
  • [45] Intraocular Lens Power Calculation Based on Fourier-Domain Optical Coherence Tomography
    Tang, M.
    Li, Y.
    Huang, D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] In-focus Fourier-domain optical coherence tomography by complex numerical method
    Sando, Y
    Yasuno, Y
    Sugisaka, J
    Endo, T
    Makita, S
    Aoki, G
    Itoh, M
    Yatagai, T
    [J]. APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 16 - 17
  • [47] Tear Measurement in Prosthetic Eye Users with Fourier-Domain Optical Coherence Tomography
    Kim, Sung Eun
    Yoon, Jin Sook
    Lee, Sang Yeul
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) : 602 - 607
  • [48] Contrast improvement in Fourier-domain optical coherence tomography through time gating
    Muller, Matthew S.
    Fraser, James M.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (04) : 969 - 976
  • [49] Artifact removal in Fourier-domain optical coherence tomography with a piezoelectric fiber stretcher
    Vergnole, Sebastien
    Lamouche, Guy
    Dufour, Marc L.
    [J]. OPTICS LETTERS, 2008, 33 (07) : 732 - 734
  • [50] Signal processing with unequally spaced data in Fourier-Domain Optical Coherence Tomography
    Vergnole, Sebastien
    Levesque, Daniel
    Sherif, Sherif S.
    Lamouche, Guy
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554