The Rates of Cement Leakage Following Vertebroplasty in Osteoporotic versus Metastatic Disease

被引:6
|
作者
Saad, Ahmed [1 ]
Botchu, Rajesh [2 ]
James, Steven [2 ]
机构
[1] Royal Orthopaed Hosp, Dept Orthoped, Birmingham, W Midlands, England
[2] Royal Orthopaed Hosp, Dept Musculoskeletal Imaging, Bristol Rd South, Birmingham, W Midlands, England
来源
关键词
vertebroplasty; osteoporotic; neoplastic; leak; PERCUTANEOUS VERTEBROPLASTY; COMPRESSION FRACTURES; VERTEBRAL FRACTURES; BONE-CEMENT; KYPHOPLASTY; POLYMETHYLMETHACRYLATE; MANAGEMENT; CANCER; SPINE;
D O I
10.1055/s-0042-1744122
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Percutaneous vertebroplasty is used for symptomatic osteoporotic fractures and osteolytic neoplasms. We performed a retrospective study to analyze the pattern of leaks in the two cohorts. Material and Methods Vertebroplasties performed over a 7-year period at a tertiary orthopaedic center were included in the study and divided into osteoporotic and neoplastic groups. The incidence and pattern of cement leaks in each group were documented and analyzed. Results There were 75 leaks of a cohort of 211 vertebroplasties with a relatively equal proportion in osteoporotic and neoplastic groups. The incidence of discal leaks was comparable between the two groups. Lateral and posterior leaks were more common in the neoplastic group. Conclusion We report the incidence and type of leaks in osteoporotic and neoplastic groups. Understanding the fracture pattern and preoperative management are both essential in preventing cement leakage. Using highly viscous cement or allowing the cement to harden prior to injection, with use of low pressure, decreases the risk and incidence of cement leakage.
引用
收藏
页码:46 / 50
页数:5
相关论文
共 50 条
  • [21] Identification of Risk Factors for the Occurrence of Cement Leakage During Percutaneous Vertebroplasty for Painful Osteoporotic or Malignant Vertebral Fracture
    Tome-Bermejo, Felix
    Pinera, Angel R.
    Duran-Alvarez, Carmen
    Lopez-San Roman, Belen
    Mahillo, Ignacio
    Alvarez, Luis
    Perez-Higueras, Antonio
    SPINE, 2014, 39 (11) : E693 - E700
  • [22] Feasibility, Safety and Cement Leakage in Vertebroplasty of Osteoporotic and Malignant Compression Fractures Using Ultra-Viscous Cement and Hydraulic Delivery System
    Georgy, Bassem
    PAIN PHYSICIAN, 2012, 15 (03) : 223 - 228
  • [23] Intradural cement leakage:: a rare complication of percutaneous vertebroplasty
    Sabuncuoglu, H.
    Dincer, D.
    Gueclue, B.
    Erdogan, E.
    Hatipoglu, H. G.
    Oezdogan, S.
    Timurkaynak, E.
    ACTA NEUROCHIRURGICA, 2008, 150 (08) : 811 - 815
  • [24] The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study
    Tang, Benqiang
    Xu, Songjie
    Chen, Xueming
    Cui, Libin
    Wang, Yanhui
    Yan, Xin
    Liu, Yadong
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [25] Cement leakage causes potential thermal injury in vertebroplasty
    Lai, Po-Liang
    Tai, Ching-Lung
    Chen, Lih-Huei
    Nien, Nai-Yuan
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12 : 116
  • [26] Intradural cement leakage: a rare complication of percutaneous vertebroplasty
    H. Sabuncuoğlu
    D. Dinçer
    B. Güçlü
    E. Erdoğan
    H. G. Hatipoğlu
    S. Özdoğan
    E. Timurkaynak
    Acta Neurochirurgica, 2008, 150 : 811 - 815
  • [27] Cement leakage causes potential thermal injury in vertebroplasty
    Po-Liang Lai
    Ching-Lung Tai
    Lih-Huei Chen
    Nai-Yuan Nien
    BMC Musculoskeletal Disorders, 12
  • [28] Intradural cement leakage - A devastatingly rare complication of vertebroplasty
    Chen, Yen-Jen
    Tan, Tai-Sheng
    Chen, Wen-Hsien
    Chen, Clayton Chi-Chang
    Lee, Tu-Sheng
    SPINE, 2006, 31 (12) : E379 - E382
  • [29] The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study
    Benqiang Tang
    Songjie Xu
    Xueming Chen
    Libin Cui
    Yanhui Wang
    Xin Yan
    Yadong Liu
    BMC Musculoskeletal Disorders, 22
  • [30] Complications in Percutaneous Vertebroplasty Associated with Puncture or Cement Leakage
    Clemens Baumann
    Heiko Fuchs
    Jürgen Kiwit
    Kerstin Westphalen
    Johannes Hierholzer
    CardioVascular and Interventional Radiology, 2007, 30 : 161 - 168