Profile measurement of microwave antenna using close range photogrammetry

被引:6
|
作者
Lu, NG [1 ]
Deng, WY [1 ]
Wang, YQ [1 ]
Dong, ML [1 ]
机构
[1] Beijing Inst Machinery, Beijing 100085, Peoples R China
关键词
microwave antenna; photogrammetry; camera calibration;
D O I
10.1117/12.621553
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A digital close range photogrammetric method for space deployable microwave antenna is presented. The planning of multi-camera stations, 3D data connection of images of different view field and the calibration of the cameras are discussed. The procedure of calibration has two steps: direct linear transformation and the bundle adjustment. The measurement error resulted from lens distortion can be corrected. The relative accuracy of I part in 1000 can be achieved using on site automatic calibration during measurement. The profile of the space deployable microwave antenna was obtained through the least squares fitting of the adjusted observations.
引用
收藏
页码:508 / 514
页数:7
相关论文
共 50 条
  • [41] AN APPLICATION OF CLOSE RANGE PHOTOGRAMMETRY IN SHIPBUILDING
    COCHRANE, J
    PHOTOGRAMMETRIC RECORD, 1989, 13 (73): : 63 - 67
  • [42] Control work in close range photogrammetry
    Wuhan Cehui Keji Daxue Xuebao/Journal of Wuhan Technical University of Surveying and Mapping, 2000, 25 (05): : 453 - 458
  • [43] MICROWAVE TECHNIQUE FOR REFLECTOR ANTENNA PROFILE MEASUREMENT
    BENNETT, JC
    SWAN, DG
    ELECTRONICS LETTERS, 1985, 21 (13) : 560 - 561
  • [44] Close range photogrammetry in volume computing
    H. M. Yilmaz
    Experimental Techniques, 2010, 34 : 48 - 54
  • [45] CONTROL WORK IN CLOSE RANGE PHOTOGRAMMETRY
    FENG Wenhao
    Geo-Spatial Information Science, 2001, (04) : 66 - 72
  • [46] IS THERE A FUTURE FOR FILM IN CLOSE RANGE PHOTOGRAMMETRY
    ROBSON, S
    PHOTOGRAMMETRIC RECORD, 1991, 13 (77): : 703 - 716
  • [47] PRECISION AND SPEED IN CLOSE RANGE PHOTOGRAMMETRY
    CHISHOLM, NWT
    PHOTOGRAMMETRIC RECORD, 1983, 11 (61): : 97 - 100
  • [48] Close range photogrammetry for industrial applications
    Luhmann, Thomas
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2010, 65 (06) : 558 - 569
  • [49] Two-dimensional displacement measurement using static close range photogrammetry and a single fixed camera
    Khalil, Abdallah M.
    ALEXANDRIA ENGINEERING JOURNAL, 2011, 50 (03) : 219 - 227
  • [50] Study on close-range photogrammetry without traditional selfcalibration measurement model
    Long Changyu
    Wan Bile
    Yang Zaihua
    Liu Haomiao
    Tao Li
    Ruan Guowei
    Liu Yugang
    Wei Yuee
    AOPC 2017: 3D MEASUREMENT TECHNOLOGY FOR INTELLIGENT MANUFACTURING, 2017, 10458