Triple valve replacement with bileaflet mechanical valves - Is the mechanical valve the proper choice for the tricuspid position?

被引:6
|
作者
Tayama, E [1 ]
Kawano, H [1 ]
Takaseya, T [1 ]
Hiratsuka, R [1 ]
Oda, T [1 ]
Hayashida, N [1 ]
Fukunaga, S [1 ]
Aoyagi, S [1 ]
机构
[1] Kurume Univ, Sch Med, Dept Surg, Kurume, Fukuoka 8300011, Japan
来源
关键词
ATS valve; bileaflet mechanical valve; St Jude Medical (SJM) valve; tricuspid valve replacement; triple valve replacement;
D O I
10.1253/jcj.65.257
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
A more durable mechanical valve may be a better choice for the tricuspid position than a bioprosthesis when the patient already has mechanical prosthesis in the left side of the heart. Eleven cases of triple valve replacement (total follow-up period, 49.5 patient years), all with mechanical valves, are reviewed to assess optimal valve selection. Nine patients had undergone a total of 12 previous cardiac surgeries. Three patients died in hospital (27.3%), but there were no late deaths among the survivors. Two cases of valve thrombosis in the tricuspid position occurred (linearized incidence: 4.04%/patient years) and 1 of these required reoperation. Because of this high incidence of valve thrombosis, the bileaflet mechanical valve is not considered to be the best choice. Even if mechanical valves are implanted in the left side of the heart, a bioprosthesis may be a better choice at the tricuspid position.
引用
收藏
页码:257 / 260
页数:4
相关论文
共 50 条
  • [31] Mechanical versus biological prostheses in patients with tricuspid valve replacement
    Carrier, M
    Hebert, Y
    Pellerin, M
    Bouchard, D
    Perrault, LP
    Cartier, R
    Page, P
    Poirier, N
    CIRCULATION, 2002, 106 (19) : 554 - 554
  • [32] TRICUSPID-VALVE REPLACEMENT - PORCINE BIOPROSTHESES AND MECHANICAL PROSTHESES
    MUNRO, AI
    JAMIESON, WRE
    TYERS, GFO
    GERMANN, E
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S470 - S474
  • [33] Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement
    Alskaf, Ebraham
    Laskar, Nabila
    McConkey, Hannah
    Kardos, Attila
    HEART SURGERY FORUM, 2016, 19 (03): : E116 - E117
  • [34] Lipids in patients with aortic valve replacement: Impact of preoperative cholesterol levels on the embolization after bileaflet mechanical valve replacement
    Nollert, G
    Schrepfer, S
    Deuse, T
    Reichart, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 433A - 433A
  • [35] Effects of Dobutamine on aortic valve indexes in asymptomatic patients with bileaflet mechanical prostheses in the aortic valve position
    Tsai, CH
    Lee, TM
    Wang, CH
    Hsu, KL
    Liau, CS
    Lee, YT
    Chu, SH
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (11): : 1546 - &
  • [36] Thrombotic occlusion of a bileaflet, mechanical mitral valve
    Pybus, David A.
    ANESTHESIA AND ANALGESIA, 2007, 105 (06): : 1567 - 1568
  • [37] Mechanical valve thrombosis in a chronic animal model: Differences between monoleaflet and bileaflet valves
    Meuris, B
    Verbeken, E
    Flameng, W
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (01): : 96 - 104
  • [38] Wavelet analysis of bileaflet mechanical valve sounds
    Hiroshi Sugiki
    Norihiko Shiiya
    Toshifumi Murashita
    Takashi Kunihara
    Kenji Matsuzaki
    Takehiro Kubota
    Yoshiro Matsui
    Kenji Sugiki
    Journal of Artificial Organs, 2007, 10 : 16 - 21
  • [39] Wavelet analysis of bileaflet mechanical valve sounds
    Sugiki, Hiroshi
    Shiiya, Norihiko
    Murashita, Toshifumi
    Kunihara, Takashi
    Matsuzaki, Kenji
    Kubota, Takehiro
    Matsui, Yoshiro
    Sugiki, Kenji
    JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (01) : 16 - 21
  • [40] Swirling Flow in Bileaflet Mechanical Heart Valve
    Gataulin, Yakov A.
    Khorobrov, Svyatoslav V.
    Yukhnev, Andrey D.
    EIGHTH POLYAKHOV'S READING, 2018, 1959