Status of the Nevada Shocker at the Univeristy of Nevada Las Vegas

被引:0
|
作者
Schill, RA [1 ]
Culbreth, W [1 ]
Nielsen, C [1 ]
Popek, M [1 ]
Sipe, N [1 ]
Blackstone, B [1 ]
Goldfarb, S [1 ]
Fitzgerald, W [1 ]
Larson, J [1 ]
Walker, M [1 ]
Nosal, S [1 ]
Lull, G [1 ]
Viggato, J [1 ]
Raymond, T [1 ]
Subramanian, V [1 ]
Kant, R [1 ]
Murugan, B [1 ]
Capar, S [1 ]
机构
[1] Elect & Comp Engn Dept, Las Vegas, NV 89154 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Nevada Shocker is a 540 kV, 7 Omega, 50 ns pulsed power device based on Marx Bank and Blumlein technologies. The Marx bank is composed of nine 60 kV capacitors charged in series with a Gamma High Voltage source connected by means of Ross relays in an air environment. A trigatron switch energized with an isolated mini capacitor bank is used to erect the Marx Bank. The trigatron switch and erecting electrodes are contained in a gas manifold pressurized to 20 1 psi with dry air. The energy is released sequentially through an inductor and a water filled charging transmission line to the Blumlein immersed in deionized water. The Blumlein shapes and compresses the energy into a 50 ns pulse upon discharge. A self-breaking water switch initiates the release of energy in the Blumlein. The energy flows through a water filled discharging transmission line to the diode end of the Nevada Shocker. The current diode end of the Blumlein supports vacuum pressures as low as 6.5 x 10(-6) Torr. The chamber is pumped with the aid of a roughing pump and a cryogenic vacuum pump. The vacuum section of the Nevada Shocker is currently being rebuilt to incorporate mechanical and thermal loading capabilities with sensors located at the experiment. A number of diagnostic developments are currently underway to support flashover studies on plastics. Resistive probe and differential B-dot diagnostics with the aid of a 6 GHz 20 GS/s TDS 6604 real time scope will be documented demonstrating the capability of the machine.
引用
收藏
页码:1229 / 1232
页数:4
相关论文
共 50 条