Determination of trace elements in undiluted wine samples using an automatized total sample consumption system coupled to ICP-MS

被引:0
|
作者
Cerutti, Claudia [1 ]
Sanchez, Carlos [2 ]
Sanchez, Raquel [2 ]
Ardini, Francisco [1 ]
Grotti, Marco [1 ]
Todoli, Jose-Luis [2 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, Via Dodecaneso 31, I-16146 Genoa, Italy
[2] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, POB 99, E-03080 Alicante, Spain
关键词
PLASMA-MASS SPECTROMETRY; UNIVERSAL CALIBRATION; EMISSION-SPECTROMETRY; MULTIELEMENT ANALYSIS; ALCOHOLIC BEVERAGES; RED WINE; METALS; CLASSIFICATION; DESOLVATION; BIOETHANOL;
D O I
10.1039/c8ja00391b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the elemental analysis of undiluted wine samples was optimized and validated. The method was based on the use of a high-temperature torch integrated sample introduction system (hTISIS) coupled to inductively coupled plasma mass spectrometry (ICP-MS). The operating conditions (hTISIS temperature and liquid flow rate) were optimized in terms of sensitivity and matrix effects. Low liquid flow rates allowed continuous introduction of organic samples into the plasma source with minimum soot as well as salt deposit formation at the ICP-MS interface and/or plasma thermal degradation. A double pass Scott-type spray chamber thermostated at 2 degrees C was taken as the reference sample introduction system. The results indicated that the hTISIS operated at 125 degrees C and a liquid flow rate of 30 mL min(-1) improved the sensitivity and mitigated the extent of matrix effects compared to the conventional system. Once the optimum conditions were selected, the method was validated and applied to the determination of sixteen trace elements (Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Mo, Cd, Nd, Sm, Gd, Tb and Pb) in ten real wine samples. The sample was merely aspirated to the nebulizer with no additional preparation. For the sake of comparison, the samples were microwave digested and analyzed using a conventional setup. Method detection limits achieved by the hTISIS were 2 to 40 times lower than those found using the standard procedure and ranged from 0.002 to 6 mg kg(-1). Furthermore, the accuracy of the quantification using the hTISIS was not significantly different as compared to that afforded by the conventional procedure and substantially improved in comparison with the direct analysis of wine using a Scott spray chamber. The sample throughput was close to 10 h(-1), which was in clear contrast with 2 h(-1), estimated when the digestion method was used. Finally, the suitability of the developed method for the routine analysis of wine samples was demonstrated by performing a 20 hour long analysis sequence. Good signal stability and accurate results were obtained for ten representative Italian and Spanish wines.
引用
收藏
页码:674 / 682
页数:9
相关论文
共 50 条
  • [41] SAMPLE PREPARATION FOR DETERMINATION OF RARE EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY ICP-MS: A CRITICAL REVIEW
    Pinto, Frederico Garcia
    Escalfoni Junior, Rainerio
    Saint'Pierre, Tatiana Dillenburg
    ANALYTICAL LETTERS, 2012, 45 (12) : 1537 - 1556
  • [42] Determination of trace elements in marine plankton by inductively coupled plasma mass spectrometry (ICP-MS)
    Arslan, Z
    Ertas, N
    Tyson, JF
    Uden, PC
    Denoyer, ER
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (03): : 273 - 282
  • [43] Minimization of sample volume with air-segmented sample injection and the simultaneous determination of trace elements by ICP-MS
    Noguchi, Osamu
    Oshima, Mitsuko
    Motomizu, Shoji
    ANALYTICAL SCIENCES, 2008, 24 (05) : 631 - 635
  • [44] Determination of trace elements in petroleum feedstocks by ICP-MS: From total content towards their distribution
    Lopez-Linares, Francisco
    Poirier, Laura
    Boduszynski, Mieczyslaw
    Rechsteiner, Carl
    Moir, Michael
    Leong, David
    Ovalles, Cesar
    Rogel, Estrella
    Nelson, Jenny
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [45] Minimization of Sample Volume with Air-segmented Sample Injection and the Simultaneous Determination of Trace Elements by ICP-MS
    Osamu Noguchi
    Mitsuko Oshima
    Shoji Motomizu
    Analytical Sciences, 2008, 24 : 631 - 635
  • [46] Determination of trace rare earth elements in rock samples including meteorites by ICP-MS coupled with isotope dilution and comparison methods
    Ebihara, Mitsuru
    Hayano, Kazuki
    Shirai, Naoki
    ANALYTICA CHIMICA ACTA, 2020, 1101 (1101) : 81 - 89
  • [47] COMPARISON OF SAMPLE PREPARATION TECHNIQUES FOR MULTIELEMENTAL ANALYSIS OF WINE SAMPLES BY ICP-MS
    Katona, R.
    Abranko, L.
    Stefanka, Zs.
    ACTA ALIMENTARIA, 2012, 41 : 83 - 91
  • [48] Determination of multiple trace elements in seawater using chelation ion chromatography and ICP-MS
    Liu Gang
    Zhong Shao-Jun
    Qu Chen-Li
    Liu Fei
    Xu Li-Jun
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2007, 28 (01): : 53 - 55
  • [49] Optimising ICP-MS for the determination of trace metals in high matrix samples
    McCurdy, E.
    Potter, D.
    Spectroscopy Europe, 2001, 13 (03): : 16 - 20
  • [50] Determination of Trace Elements in Edible Nuts in the Beijing Market by ICP-MS
    Yin Liang Liang
    Tian Qing
    Shao Xian Zhang
    Kong Xiang Yin
    Ji Yan Qin
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2015, 28 (06) : 449 - 454