Effect of low-frequency but high-intensity noise exposure on swine brain blood barrier permeability and its mechanism of injury

被引:7
|
作者
Wang, Xiaoyun [1 ]
Lai, Yaowen [5 ]
Zhang, Xiaojian [1 ]
Zhao, Jie [2 ,3 ,4 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Pharm, Zhengzhou 450052, Henan, Peoples R China
[2] Zhengzhou Univ, Affiliated Hosp 1, Zhengzhou 450052, Henan, Peoples R China
[3] Henan Engn Res Ctr Digital Med, Zhengzhou 450052, Henan, Peoples R China
[4] Henan Engn Lab Digital Telemed Serv, Zhengzhou 450052, Henan, Peoples R China
[5] Peoples Hosp Zhengzhou, Dept Pharm, Zhengzhou 450052, Henan, Peoples R China
关键词
Vibroacoustic disease; Blood-brain barrier permeability; Central nervous system; Low-frequency but high-intensity noise exposure; Tight junction proteins; Cysteinyl leukotriene receptor 1; FOCUSED ULTRASOUND; CEREBRAL-ISCHEMIA; DRUG-DELIVERY; INVOLVEMENT; VOLUME;
D O I
10.1016/j.neulet.2017.09.040
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: Vibroacousitic disease (VAD) is caused by excessive exposure to low-frequency but high-intensity noise. The integrity of the brain blood barrier (BBB) is essential for the brain. The study aimed to investigate the effect of noise exposure on the BBB. Methods: Healthy male Bama swine were exposed to 50, 70, 100, and 120 Hz, 140 dB noise for 30 min. After exposure, CT brain imaging and ex vivo fluorescent imaging of parenchymal EB leakage were performed (each group consisted of N = 3 swine). The human cerebral microvascular endothelial cells were exposed to 70 Hz, 140 dB noise for 5 min. Results: The BBB permeability assay showed that 50, 70, and 100 Hz with 140 dB noise exposure accelerated BBB permeability, and the BBB opening at 70 Hz was most serious and reversible. Additionally, CT images demonstrated that the noise-induced opening of the BBB caused no intracerebral hemorrhage. This noise-induced BBB opening was related to the downregulation of zo-1 and occludin. Finally, cysteinyl leukotriene receptor 1 (CysLT1 receptor) was found to regulate noise-induced tight junction defects in vitro. Conclusions: In conclusion, noise exposure accelerates the formation of a high-permeability BBB with leaky tight junctions through a CysLT1-mediated mechanism, which warrants additional research.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 50 条
  • [21] SCATTERING OF HIGH-INTENSITY LOW-FREQUENCY ELECTROMAGNETIC WAVE BY UNBOUND ELECTRON
    FRIED, Z
    EBERLY, JH
    PHYSICAL REVIEW B, 1964, 136 (3B) : B871 - +
  • [22] Design and experiment on fluidic low-frequency and high-intensity sound generator
    Wang, Jian
    Wu, Jun-Ji
    Tao, Gang
    Nanjing Li Gong Daxue Xuebao/Journal of Nanjing University of Science and Technology, 2009, 33 (03): : 344 - 347
  • [23] The effects of high-intensity, low-frequency active sonar on rainbow trout
    Popper, Arthur N.
    Halvorsen, Michele B.
    Kane, Andrew
    Miller, Diane L.
    Smith, Michael E.
    Song, Jiakun
    Stein, Peter
    Wysocki, Lidia E.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (01): : 623 - 635
  • [24] Effect of Low-Frequency and High-Intensity Ultrasound Treatment on Characteristics of Chicken Breast Myofibrillar Protein
    Li K.
    Li S.
    Fu L.
    Zhao Y.
    Zhang Y.
    Zhao D.
    Bai Y.
    Shipin Kexue/Food Science, 2020, 41 (23): : 122 - 129
  • [25] LOW-FREQUENCY DLS - EFFECT OF A HIGH-FREQUENCY NOISE
    CAMPBELL, RA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1963, 35 (06): : 844 - &
  • [26] Controllable permeability of blood-brain barrier and reduced brain injury through low-intensity pulsed ultrasound stimulation
    Su, Wei-Shen
    Tsai, Min-Lan
    Huang, Sin-Luo
    Liu, Shing-Hwa
    Yang, Feng-Yi
    ONCOTARGET, 2015, 6 (39) : 42290 - 42299
  • [27] A low-frequency high-voltage RF-barrier bunching system for high-intensity neutron source compressor rings
    Hardek, TW
    Rees, D
    Ziomek, C
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1596 - 1598
  • [28] Acute high-intensity noise exposure exacerbates anxiety-like behavior via neuroinflammation and blood brain barrier disruption of hippocampus in male rats
    Yifei Song
    Haoyu Zhang
    Xiaoni Wang
    Lei Huang
    Yiting Kang
    Zeguo Feng
    Fadong Zhao
    Hongwei Zhuang
    Jianbao Zhang
    Behavioral and Brain Functions, 21 (1)
  • [29] ULTRASONIC TREATMENT OF TUMORS .3. HIGH-INTENSITY, LOW-FREQUENCY EXPOSURES
    CHILD, SZ
    VIVES, B
    SMACHLO, K
    FRIDD, CW
    HARE, JD
    LINKE, CA
    DAVIS, HT
    CARSTENSEN, EL
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (01): : 41 - 44
  • [30] CATHETER DELIVERED HIGH-INTENSITY LOW-FREQUENCY ULTRASOUND CAUSES VASODILATION INVIVO
    STEFFEN, W
    LUO, H
    CUMBERLAND, DC
    GAINES, P
    FISHBEIN, MC
    MAURER, G
    SIEGEL, RJ
    CLINICAL RESEARCH, 1993, 41 (01): : A11 - A11