An improved optimal image sampling schedule for multiple ROIS in dynamic SPECT

被引:0
|
作者
Wen, LF [1 ]
Eberl, S [1 ]
Feng, DG [1 ]
Bai, J [1 ]
机构
[1] Tsinghua Univ, Dept Biomed Engn, Beijing 100084, Peoples R China
来源
MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2003 (INCLUDING BIOLOGICAL SYSTEMS) | 2003年
关键词
sampling intervals; Monte Carlo simulation; parameter estimation; physiological model; quantitative analysis;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Optimal image sampling schedule (OISS) has been applied successfully to dynamic images for positron emission tomography (PET) with improved parameter estimation precision and significantly decreased image storage and processing requirements. OISS is usually based on one average curve for tissue, and the performance of OISS is still unclear when multiple regions of interest are considered in clinical diagnosis. An improved OISS is investigated with a modified objective function through a simulated study of the tracer 5-I-123-iodo-A-85380. The study shows that the improved OISS is at least as efficient in providing the accuracy and precision of parameter estimates as conventional and traditional OISS.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [31] Choosing an optimal sampling schedule for the identification of minimal model insulin sensitivity
    Steil, GM
    MINIMAL MODEL APPROACH AND DETERMINANTS OF GLUCOSE TOLERANCE, 1997, 7 : 123 - 141
  • [32] Content-Based Image Retrieval Method using the Relative Location of Multiple ROIs
    Lee, Jongwon
    Nang, Jongho
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2011, 11 (03) : 85 - 90
  • [33] Optimal unbiased reduction of global image variances in SPECT
    Pan, XC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1148 - 1155
  • [34] Optimal unbiased reduction of global image variances in SPECT
    Pan, Xiaochuan
    IEEE Transactions on Nuclear Science, 1999, 46 (4 II): : 1148 - 1155
  • [35] Effects of sampling rate on the estimation of dynamic processes in SPECT.
    Zhang, N
    Chingas, GC
    Budinger, TF
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 381 - 381
  • [36] Design of temporal sampling schedules for dynamic cardiac FDG SPECT
    Khare, HS
    DiBella, EVR
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1346 - 1350
  • [37] Optimal log-polar image sampling
    Peric, Z.
    Dincic, M.
    Jovanovic, A.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2009, 54 (12) : 1397 - 1402
  • [38] Optimal log-polar image sampling
    Z. Perić
    M. Dinčić
    A. Jovanović
    Journal of Communications Technology and Electronics, 2009, 54 : 1397 - 1402
  • [39] Regional SPECT Imaging Using Sampling Principles and Multiple Pinholes
    Bowsher, James E.
    Roper, Justin R.
    Yan, Susu
    Giles, William M.
    Yin, Fang-Fang
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2071 - 2076
  • [40] Quadrature sampling schemes with improved image rejection
    Pun, KP
    da Franca, JE
    Azeredo-Leme, C
    Reis, R
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 2003, 50 (09): : 641 - 648