Optical diagnosis of gastric cancer using near-infrared multichannel Raman spectroscopy with a 1064-nm excitation wavelength

被引:41
|
作者
Kawabata, Toshiki [1 ]
Mizuno, Toshihiko [2 ]
Okazaki, Shigetoshi [2 ]
Hiramatsu, Mitsuo [2 ]
Setoguchil, Tomohiko [1 ]
Kikuchi, Hirotoshi [1 ]
Yamamoto, Masayoshi [1 ]
Hiramatsu, Yoshihiro [1 ]
Kondo, Kenji [1 ]
Baba, Megumi [1 ]
Ohta, Manabu [1 ]
Kamiya, Kinji [1 ]
Tanaka, Tatsuo [1 ]
Suzuki, Shohachi [1 ]
Konno, Hiroyuki [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Surg 2, Higashi Ku, Hamamatsu, Shizuoka 4313192, Japan
[2] Hamamatsu Photon KK, Shizuoka, Japan
关键词
gastric cancer; Raman spectroscopy; optical biopsy; endoscopy;
D O I
10.1007/s00535-008-2160-2
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Gastric cancer is one of the most common cancers in Japan. The use of endoscopy is increasing, along with the number of histological examinations of specimens obtained by endoscopy. However, it takes several days to reach a diagnosis, which increases the medical expense. Raman spectroscopy is one of the available optical techniques, and the Raman spectrum for each molecule and tissue is characteristic and specific. The present study investigated whether Raman spectroscopy can be used to diagnose gastric cancer. Methods. A total of 251 fresh biopsy specimens of gastric carcinoma and non-neoplastic mucosa were obtained from 49 gastric cancer patients at endoscopy. Without any pretreatment, the fresh specimens were measured with a near-infrared multichannel Raman spectroscopic system with an excitation wavelength of 1064nm, and Raman spectra specific for the specimens were obtained. A principal component analysis (PCA) was performed to distinguish gastric cancer and nonneoplastic tissue, and a discriminant analysis was used to evaluate the accuracy of the gastric cancer diagnosis. Results. The Raman spectra for cancer specimens differed from those for non-neoplastic specimens, especially at around 1644 cm(-1). Sensitivity was 66 %, specificity was 73 %, and accuracy was 70 %. The accuracy of diagnosis using the single Raman scattering intensity at 1644cm(-1) was 70%, consistent with the PCA result. Conclusions. The present results indicate that near-infrared multichannel Raman spectroscopy with a 1064nm excitation wavelength is useful for gastric cancer diagnosis. Establishment of a Raman diagnostic system for gastric cancer may improve the clinical diagnosis of gastric cancer and be beneficial for patients.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [41] Raman spectrum of β-carotene using laser lines from green (514.5 nm) to near-infrared (1064 nm):: Implications for the characterization of conjugated polyenes
    Parker, SF
    Tavender, SM
    Dixon, NM
    Herman, HK
    Williams, KPJ
    Maddams, WF
    APPLIED SPECTROSCOPY, 1999, 53 (01) : 86 - 91
  • [42] Raman spectrum of β-carotene using laser lines from green (514.5 nm) to near-infrared (1064 nm): Implications for the characterization of conjugated polyenes
    Rutherford Appleton Lab, Oxon, United Kingdom
    Appl Spectrosc, 1 (86-91):
  • [43] DEMONSTRATION OF LOW-FREQUENCY PERFORMANCE AND MICROANALYSIS CAPABILITY OF MULTICHANNEL RAMAN-SPECTROSCOPY WITH NEAR-INFRARED EXCITATION .1.
    BARBILLAT, J
    DASILVA, E
    ROUSSEL, B
    JOURNAL OF RAMAN SPECTROSCOPY, 1991, 22 (07) : 383 - 391
  • [44] Focus diagnosis of epilepsy using near-infrared spectroscopy
    Watanabe, E
    Nagahori, Y
    Mayanagi, Y
    EPILEPSIA, 2002, 43 : 50 - 55
  • [45] Development of an optical system for the detection of oral cancer using near-infrared spectroscopy
    Cooney, KM
    Gossage, KW
    McShane, MJ
    van der Breggen, EWJ
    Motamedi, M
    Coté, GL
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 906 - 909
  • [46] FOURIER-TRANSFORM RAMAN-SPECTROSCOPY AS A ROUTINE ANALYTICAL TOOL USING NEAR-INFRARED EXCITATION
    HANNIET, M
    JAWHARI, T
    ROYAUD, IAM
    JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1989, 86 (03) : 431 - 450
  • [47] Optical wavelength selection for portable hemoglobin determination by near-infrared spectroscopy method
    Tian, Han
    Li, Ming
    Wang, Yue
    Sheng, Dinggao
    Liu, Jun
    Zhang, Linna
    INFRARED PHYSICS & TECHNOLOGY, 2017, 86 : 98 - 102
  • [48] Recent applications of near-infrared spectroscopy in cancer diagnosis and therapy
    Venkata Radhakrishna Kondepati
    H. Michael Heise
    Juergen Backhaus
    Analytical and Bioanalytical Chemistry, 2008, 390
  • [49] Recent applications of near-infrared spectroscopy in cancer diagnosis and therapy
    Kondepati, Venkata Radhakrishna
    Heise, H. Michael
    Backhaus, Juergen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (01) : 125 - 139
  • [50] NEAR-INFRARED RAMAN-SPECTROSCOPY WITH 782 AND 830 NM DIODE-LASERS
    WANG, Y
    ALLRED, C
    MCCREERY, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 112 - ANYL