The measurement of the EAS charged particle component using a logarithmic ADC

被引:0
|
作者
Hovsepyan, GG [1 ]
机构
[1] Yerevan Phys Inst, Cosm Ray Div, Yerevan 375036, Armenia
来源
PROCEEDINGS OF THE WORKSHOP ANI 98: CURRENT TOPICS OF COSMIC RAY RESEARCH WITH EAS OBSERVATIONS | 1998年 / 6215卷
关键词
D O I
暂无
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
For a nonlinear electronic system like a logarithmic ADC, it is impossible to derive an absolutely correct transformation. This can be a source of additional experimental errors. A hardware system is developed to obtain a priori information (the slope of background particles spectra) and to estimate the scale faster of transformation. Results of detector calibration and response simulation are presented.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [21] Boron concentration measurement in biological tissues by charged particle spectrometry
    Bortolussi, S.
    Altieri, S.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2013, 52 (04) : 493 - 503
  • [22] A METHOD FOR MEASUREMENT OF CHARGED PARTICLE ELASTIC SCATTERING AT SMALL ANGLES
    BUTSLOV, MM
    MEDVEDEV, MN
    SHESHUNOV, VM
    NUCLEAR INSTRUMENTS & METHODS, 1963, 20 (JAN): : 242 - 244
  • [23] Boron concentration measurement in biological tissues by charged particle spectrometry
    S. Bortolussi
    S. Altieri
    Radiation and Environmental Biophysics, 2013, 52 : 493 - 503
  • [24] Measurement of neutron and charged particle fluxes toward earthquake prediction
    Asatulla U.Maksudov
    Mars A.Zufarov
    Earthquake Science, 2017, (Z1) : 283 - 288
  • [25] Measurement of the charged particle multiplicity of weakly decaying B hadrons
    Abreu, P
    Adam, W
    Adye, T
    Adzic, P
    Ajinenko, I
    Alekseev, GD
    Alemany, R
    Allport, PP
    Almehed, S
    Amaldi, U
    Amato, S
    Andersson, P
    Andreazza, A
    Antilogus, P
    Apel, WD
    Arnoud, Y
    Asman, B
    Augustin, JE
    Augustinus, A
    Baillon, P
    Bambade, P
    Barao, F
    Barbier, R
    Bardin, DY
    Barker, G
    Baroncelli, A
    Barring, O
    Battaglia, M
    Baubillier, M
    Becks, KH
    Begalli, M
    Beilliere, P
    Belokopytov, Y
    Benvenuti, AC
    Berat, C
    Berggren, M
    Bertini, D
    Bertrand, D
    Besancon, M
    Bianchi, F
    Bigi, M
    Bilenky, MS
    Bizouard, MA
    Bloch, D
    Bonesini, M
    Bonivento, W
    Boonekamp, M
    Booth, PSL
    Borgland, AW
    Borisov, G
    PHYSICS LETTERS B, 1998, 425 (3-4) : 399 - 412
  • [26] DEVICE FOR PRECISE MEASUREMENT OF CHARGED-PARTICLE BEAM INTENSITY
    VARMA, MN
    BAUM, JW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (01): : 1 - 3
  • [27] SEMIAUTOMATIC APPARATUS FOR MEASUREMENT OF PHOTOGRAPHS OF CHARGED-PARTICLE TRACKS
    STABNIKO.MV
    TURUKHAN.BG
    DOBYRN, VV
    MISHCHEN.IS
    LUKASHUN.NI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (05): : 1079 - &
  • [28] Charged particle flow measurement for |η|<5.3 with the PHOBOS detector
    Park, I
    NUCLEAR PHYSICS A, 2002, 698 : 564C - 567C
  • [29] Review of linear optics measurement and correction for charged particle accelerators
    Tomas, Rogelio
    Aiba, Masamitsu
    Franchi, Andrea
    Iriso, Ubaldo
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2017, 20 (05):
  • [30] MULTIPLICITY MEASUREMENT OF EVAPORATED CHARGED-PARTICLES IN PARTICLE-PARTICLE COINCIDENCE EXPERIMENT
    CHANG, CC
    COWLEY, AA
    HOLMGREN, HD
    KOONTZ, RW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (04): : 521 - 521