Evaluation of Camera Motion in Stereo-DIC

被引:3
|
作者
Balcaen, R. [1 ]
Reu, P. L. [2 ]
Lava, P. [3 ]
Debruyne, D. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Mat Technol, Campus Ghent,Gebroeders Desmetstr 1, B-9000 Ghent, Belgium
[2] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[3] MatchID, Wijmenstr 21T, B-9000 Ghent, Belgium
来源
INTERNATIONAL DIGITAL IMAGING CORRELATION SOCIETY | 2017年
基金
美国能源部;
关键词
Stereo-DIC; Uncertainty quantification; Optical techniques; Camera motion; Error assessment;
D O I
10.1007/978-3-319-51439-0_1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The full-field nature of stereo-digital image correlation (stereo-DIC) makes it a widespread technique with vast possibilities. The uncertainty quantification of the technique is however not yet fully understood due to the non-linear optical-numerical measurement chain, limiting analytical research of the technique. Camera motion is a perfect example of this; it is hard to measure and the influence of it is not yet investigated. A simulator (presented in [Balcaen et al. Finite element based image generator for stereo-DIC uncertainty quantification applied on stereo-DIC calibration, 2016] and used in [Balcaen et al. Stereo-DIC uncertainty quantification based on simulated images, 2016]) is used to study how camera motion during a test influences the resulting deformation-and strain-field. Since the exact imposed deformation-field is known in a simulator the resulting errors can be clearly identified. Camera motion between the calibration-stage and the actual measurement is not investigated since this comes down to a poorly calibrated rig. We refer to the literature for more information concerning the influence of poor calibration data on measurement results. Numerous tests indicate that small camera-rotations can introduce a linear displacement-offset and thus also a constant strain-offset, mainly depending on the focal length of the lenses and the angle of rotation. Camera translation on the other side seems to be less pernicious.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 50 条
  • [41] Motion Pose Estimated Based on the Binocular Stereo Camera
    Jin Tao
    Jia Hongzhi
    Hou Wenmei
    Yamamoto, Ryo
    Nagai, Norihiro
    Fujii, Yusaku
    Maru, Koichi
    Ohta, Naoya
    Shimada, Kazuhito
    PRECISION INSTRUMENTATION AND MEASUREMENT, 2010, 36 : 494 - +
  • [42] Bubble assisted vacuum thermoforming: considerations to extend the use of in-situ stereo-DIC measurements to stretching of sagged thermoplastic sheets
    Ayadi, A.
    Lacrampe, M. -F.
    Krawczak, P.
    INTERNATIONAL JOURNAL OF MATERIAL FORMING, 2020, 13 (01) : 59 - 76
  • [43] ACCURACY EVALUATION OF STEREO CAMERA SYSTEMS WITH GENERIC CAMERA MODELS
    Ruess, Dominik
    Luber, Andreas
    Manthey, Kristian
    Reulke, Ralf
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION V, 2012, 39-B5 : 375 - 380
  • [44] Evaluation of a low-cost approach to 2-D digital image correlation vs. a commercial stereo-DIC system in Brazilian testing of soil specimens
    Arza-Garcia, M.
    Nunez-Temes, C.
    Lorenzana, J. A.
    Ortiz-Sanz, J.
    Castro, A.
    Portela-Barral, M.
    Gil-Docampo, M.
    Bastos, G.
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2021, 22 (01)
  • [45] Bubble assisted vacuum thermoforming: considerations to extend the use of in-situ stereo-DIC measurements to stretching of sagged thermoplastic sheets
    A. Ayadi
    M.-F. Lacrampe
    P. Krawczak
    International Journal of Material Forming, 2020, 13 : 59 - 76
  • [46] Reliability of Hybrid Inverse Identification Based on Stereo-DIC Measurements to Assess HIPS Hyperelastic Parameters: Case of Isothermal Tensile Loads
    Dastidar, Aniket Ghosh
    Ayadi, Abderrahmane
    Lacrampe, Marie-France
    23RD INTERNATIONAL CONFERENCE ON MATERIAL FORMING, 2020, 47 : 933 - 939
  • [47] Stereo-Digital Image Correlation (DIC) measurements with a single camera using a biprism
    Genovese, K.
    Casaletto, L.
    Rayas, J. A.
    Flores, V.
    Martinez, Amalia
    OPTICS AND LASERS IN ENGINEERING, 2013, 51 (03) : 278 - 285
  • [48] Precise binocular stereo by camera motion (Precise binocular stereo using image-blurring effect and camera swiveling)
    Kato, Koji, 1600, Publ by Scripta Technica Inc, New York, NY, United States (24):
  • [49] Assessment of Principal Strain Uncertainties in Stereo-DIC Due to Uncontrollable Change of Initial Boundary Conditions During Vacuum-Assisted Thermoforming
    Ayadi, A.
    Lacrampe, M-F.
    Krawczak, P.
    PROCEEDINGS OF THE 22ND INTERNATIONAL ESAFORM CONFERENCE ON MATERIAL FORMING (ESAFORM 2019), 2019, 2113
  • [50] THE APPLICATION OF THE STEREO CAMERA FOR EVALUATION OF TRAINING EFFECT
    OKI, H
    NAGATA, Y
    BULLETIN OF EQUINE RESEARCH INSTITUTE, 1982, (19): : 38 - 42