Measurement of lumbar lordosis - Evaluation of intraobserver, interobserver, and technique variability - Point of view

被引:0
|
作者
Shaffer, WO
机构
关键词
D O I
10.1097/00007632-199607010-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
引用
收藏
页码:1535 / 1536
页数:2
相关论文
共 50 条
  • [1] Measurement of lumbar lordosis - Evaluation of intraobserver, interobserver, and technique variability
    Polly, DW
    Kilkelly, FX
    McHale, KA
    Asplund, LM
    Mulligan, M
    Chang, AS
    [J]. SPINE, 1996, 21 (13) : 1530 - 1535
  • [2] Measurement of thoracic and lumbar fracture kyphosis - Evaluation of intraobserver, interobserver, and technique variability - Point of view
    Haher, TR
    [J]. SPINE, 2001, 26 (01) : 66 - 66
  • [3] Measurement of thoracic and lumbar fracture kyphosis - Evaluation of intraobserver, interobserver, and technique variability
    Kuklo, TR
    Polly, DW
    Owens, BD
    Zeidman, SM
    Chang, AS
    Klemme, WR
    [J]. SPINE, 2001, 26 (01) : 61 - 65
  • [4] Lumbar lordosis measurement: A new method versus Cobb technique - Point of view
    Stokes, IAF
    [J]. SPINE, 1998, 23 (01) : 79 - 80
  • [5] INTEROBSERVER AND INTRAOBSERVER VARIABILITY IN THE INTERPRETATION OF COMPUTED-TOMOGRAPHY OF THE LUMBAR SPINE
    COSTE, J
    JUDET, O
    BARRE, O
    SIAUD, JR
    DELARA, AC
    PAOLAGGI, JB
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1994, 47 (04) : 375 - 381
  • [6] Interobserver and Intraobserver Variability in the Sonographic Measurement of the Size of the Thyroid Gland by Extended Field-of-View Sonography
    Turgut, Ahmet Tuncay
    Coskun, Zafer Unsal
    Ergun, Elif
    Kosar, Pinar
    Geyik, Pinar Ozdemir
    Gorar, Suheyla
    Kosar, Ugur
    [J]. JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2008, 24 (03) : 147 - 154
  • [7] INTEROBSERVER AND INTRAOBSERVER VARIABILITY IN INTERPRETATION OF LUMBAR DISC ABNORMALITIES - A COMPARISON OF 2 NOMENCLATURES
    BRANTZAWADZKI, MN
    JENSEN, MC
    OBUCHOWSKI, N
    ROSS, JS
    MODIC, MT
    [J]. SPINE, 1995, 20 (11) : 1257 - 1263
  • [8] Intraobserver and interobserver variability of transesophageal echocardiography in aortic arch atheroma measurement
    Weber, Annemarie
    Jones, Elizabeth F.
    Zavala, Jorge A.
    Ponnuthurai, Francis A.
    Donnan, Geoffrey A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (02) : 129 - 133
  • [9] Intraobserver and Interobserver Measurement Variability of the Rib-Vertebral Angle Difference
    Tysklind, Robert G.
    Myung, Karen
    Gantsoudes, George
    Kishan, Shyam
    Turner, Chad
    Lee, Stella
    Wanner, Matthew
    Sabatino, Meagan
    Linger, Scott
    Loder, Randall T.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2018, 38 (09) : 455 - 458
  • [10] Interobserver and Intraobserver Variability in the Identification of the Lenke Classification Lumbar Modifier in Adolescent Idiopathic Scoliosis
    Duong, Luc
    Cheriet, Farida
    Labelle, Hubert
    Cheung, Kenneth M. C.
    Abel, Mark F.
    Newton, Peter O.
    McCall, Richard E.
    Lenke, Lawrence G.
    Stokes, Ian A. F.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (06): : 448 - 455