Gigabit High Speed TCP Data Transmission for Positron Emission Tomography

被引:3
|
作者
Humbert, B. [1 ]
Bard, P. [1 ]
Fuchs, C. [1 ]
Brasse, D. [1 ]
机构
[1] Univ Strasbourg, IPHC, CNRS, IN2P3, Strasbourg, France
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
SYSTEM;
D O I
10.1109/NSSMIC.2009.5401978
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of a new tri-modality preclinical Computed Tomography apparatus (mu CT), Single Photon Emission Computed Tomography apparatus (mu SPECT) and Positron Emission Tomography apparatus (mu PET) dedicated to small animal imaging tomography is underway in the group ImaBIO at the Institut Pluridisciplinaire Hubert Curien. The mu CT and mu SPECT scanners are working quite fine and now used by biologists. Now the team is concentrated on the building of the mu PET part of the imaging platform. PET Data AcQuisition (DAQ) requires in particular the detection of coincident events. In the developing mu PET, the coincidence window is less than 1 ns. This constraint and the number of detection channels (6144) discredit an hardware solution. Moreover the lack of an hardware trigger dictates the readout of all the detected events and an absolute time stamp on each event. In this context the development of a Gigabit High Speed Transmission Control Protocol / Internet Protocol (TCP/IP) Data Transmission System was considered. Out of usual solutions involving high level language and expansive real time operating system, a solution based on the use of a Field Programmable Gate Array (FPGA) with an embedded processor programmed in C was chosen. The preliminary results of the first realized system show that the maximum bandwidth of the Gigabit Ethernet is reached with embedded processor available for more than 20 % of time.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 50 条
  • [21] CORRECTING POSITRON EMISSION TOMOGRAPHY DATA FOR CEREBRAL ATROPHY
    STROTHER, SC
    ROTTENBERG, DA
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05): : 631 - 632
  • [22] Influence of data interpolation on positron emission tomography image tomography reconstruction
    Yang Kun
    Liu Xin-Xin
    Li Xiao-Wei
    ACTA PHYSICA SINICA, 2013, 62 (14)
  • [23] Dictionary learning for data recovery in positron emission tomography
    Valiollahzadeh, SeyyedMajid
    Clark, John W., Jr.
    Mawlawi, Osama
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5853 - 5871
  • [24] Positron emission tomography
    Jones, Terry
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 455 - 458
  • [25] Positron emission tomography
    Feldmann, M.
    Koepp, M.
    ZEITSCHRIFT FUR EPILEPTOLOGIE, 2012, 25 (03): : 208 - 212
  • [26] POSITRON EMISSION TOMOGRAPHY
    BARRIO, JR
    PURE AND APPLIED CHEMISTRY, 1991, 63 (09) : 1290 - 1294
  • [27] POSITRON EMISSION TOMOGRAPHY
    RAICHLE, ME
    ANNUAL REVIEW OF NEUROSCIENCE, 1983, 6 : 249 - 267
  • [28] POSITRON EMISSION TOMOGRAPHY
    DELGUERRA, A
    PHYSICA SCRIPTA, 1987, T19B : 481 - 486
  • [29] Positron emission tomography
    Schwaiger, M
    Pirich, C
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 : 59 - 66
  • [30] POSITRON EMISSION TOMOGRAPHY
    YAMAMOTO, YL
    THOMPSON, CJ
    DIKSIC, M
    MEYER, E
    FEINDEL, WH
    RADIATION PHYSICS AND CHEMISTRY, 1984, 24 (3-4) : 385 - 403