Forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) variability in asymptomatic never-smoking men

被引:13
|
作者
Humerfelt, S
Eide, GE
Kvåle, G
Gulsvik, A
机构
[1] Univ Bergen, Dept Thorac Med, N-5020 Bergen, Norway
[2] Univ Bergen, Dept Epidemiol, N-5020 Bergen, Norway
来源
CLINICAL PHYSIOLOGY | 1998年 / 18卷 / 04期
关键词
community survey; spirometric recordings; within- and between-subject variability;
D O I
10.1046/j.1365-2281.1998.00115.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We examined the effects from subjects, technicians and spirometers on within-session variability in successful recordings of forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in 4989 asymptomatic never-smoking men. All eligible men aged 30-46 years living in western Norway (n = 45 380) were invited to a cross-sectional community survey. Information on respiratory symptoms, smoking habits and occupational exposures was obtained from a self-administered questionnaire. Three successful FEV1 and FVC recordings were obtained in 26 368 attendants using three dry-wedge bellow spirometers operated by 10 different technicians. Within-subject standard deviation (SD) from three recordings of FEV1 and FVC was on average 102 and 106 ml, respectively, and increased with height (14 and 17 ml, respectively, per 10 cm) and body mass index (BMI) (11 and 14 ml, respectively, per 5 kg m(-2)). Between-subject SD of the mean of three FEV1 and FVC recordings was 591 and 754 ml, respectively, and increased in groups of increasing height (43 and 40 ml, respectively, per 10 cm). Small, but significant, differences were observed between technicians in within-subject SD and in levels of FEV1 and FVC. Homogeneity of between-subject variability, necessary for linear regression analysis, was obtained using FEV1 and FVC divided by height squared. In conclusion, within-subject variability in three successful spirometric recordings was small, but dependent on height and BMI of the subjects as well as technician performance. The observed heterogeneity in between-subject variation in FEV1 and FVC levels disappeared when each variable was divided by height squared. Novel multiple linear regression equations for FEV1/height(2) and FVC/height(2) were developed to be used in evaluating the effects from occupational airborne exposures in Nordic men aged 30-46 years.
引用
收藏
页码:387 / 396
页数:10
相关论文
共 50 条
  • [41] Relation of changes in peak expiratory flow (PEF) and forced expiratory volume in 1 s (FEV1) during bronchoconstriction
    Csonka, Leon L.
    Tikkakoski, Antti
    Vuotari, Liisa
    Karjalainen, Jussi
    Lehtimaki, Lauri
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2024, 44 (06) : 447 - 453
  • [42] A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity
    Borekci, Sermin
    Demir, Tuncalp
    Dilektasli, Asli Gorek
    Uygun, Melahat
    Yildirim, Nurhayat
    BALKAN MEDICAL JOURNAL, 2017, 34 (02) : 113 - 118
  • [43] An Investigation of the Association of Forced Expiratory Volume in One Second (FEV1) with Occupational Exposures in a Sample of Rural Adults in Iowa
    Henneberger, P. K.
    Rollins, S. M.
    Humann, M. J.
    Liang, X.
    Doney, B. C.
    Kelly, K. M.
    Cox-Ganser, J. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [44] Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression
    Kavitha, A.
    Sujatha, C. M.
    Ramakrishnan, S.
    MEASUREMENT SCIENCE REVIEW, 2010, 10 (02): : 63 - 67
  • [45] A Gene-Environmental Interaction Analysis Of Forced Expiratory Volume In One Second (fev1) In The Framingham Heart Study
    Liao, S. -Y.
    Lin, X.
    Christiani, D. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [46] Change (Δ) in percent forced expiratory volume in the first second (FEV1) in 10 patients on Omalizumab over 23 months
    Shamir, K.
    Hersh, A.
    Aguila, H.
    Pepe, J.
    Wolff, A.
    Bielory, L.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 119 (01) : S11 - S11
  • [47] EFFECT OF INDUCED EMOTIONS ON 1 SECOND FORCED EXPIRATION VOLUME (FEV1) IN ASTHMATIC CHILDREN
    TAL, A
    MIKLICH, DR
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1975, 55 (02) : 125 - 125
  • [49] Predictors of improvement in FEV1 (forced expiratory volume in 1s) after lung volume reduction surgery
    Date, H
    Goto, K
    Souda, R
    Endou, S
    Aoe, M
    Yamashita, M
    Andou, A
    Shimizu, N
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 2000, 30 (04): : 328 - 332
  • [50] Rapid decline in forced expiratory volume in 1 second (FEV1) and the development of bronchitic symptoms among new Chinese coal miners
    Wang, Mei-Lin
    Wu, Zhi-En
    Du, Qin-Guo
    Peng, Kai-Liang
    Ya-Dong, U.
    Li, Shao-Kui
    Han, Gui-Hai
    Petsonk, Edward L.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2007, 49 (10) : 1143 - 1148