Dose calculations with the BEAM Monte Carlo code at extended SSD's

被引:0
|
作者
Stathakis, S [1 ]
Kappas, C [1 ]
Papanikolaou, N [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Hellas, Greece
关键词
extended SSD; Monte Carlo; dose calculation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Extended surface to Skin Distance (SSD) beam data are very useful For hemibody and total body irradiation. Monte Carlo simulation provides an alternative mechanism to calculate the dose fur such treatment modalities. Comparison of the Monte Carlo results has been done with measured data of two linear accelerators of 6 MV, with results from two commercial 3D treatment-planning systems and with extrapolated data from measurements at 100 cm SSD. The results from the Monte Carlo simulations agreed with the experimental results within 1% and the PDD curves produced from the TPS's were within 2% error. The extrapolated PDD curves had a deviation of about 2%. It was found that d(max) migrated towards the surface with increasing SSD which was predicted by the simulations. Also, the mean photon energy as computed hy the simulation was found to be higher at extended SSD which is part of the reason why the PDDs are more penetrating for extended distances.
引用
收藏
页码:1679 / 1680
页数:2
相关论文
共 50 条
  • [21] Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy
    Bazalova, Magdalena
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    MEDICAL PHYSICS, 2009, 36 (11) : 4991 - 4999
  • [22] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [23] pGPUMCD: an efficient GPU-based Monte Carlo code for accurate proton dose calculations
    Maneval, Daniel
    Ozell, Benoit
    Despres, Philippe
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08):
  • [24] Comments on 'Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations'
    Fippel, M
    Nüsslin, F
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : L17 - L18
  • [25] The FLUKA Monte Carlo Code in Ion Beam Therapy
    Rinaldi, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 298 - 298
  • [27] GPU-ACCELERATED MONTE CARLO CODE FOR FAST DOSE RECALCULATION IN PROTON BEAM THERAPY
    Rucinski, A.
    Gajewski, J.
    Olko, P.
    Rinaldi, I.
    Patera, V.
    Schiavi, A.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1625 - 1630
  • [28] COMPARISON OF ONETRAN CALCULATIONS OF ELECTRON-BEAM DOSE PROFILES WITH MONTE-CARLO AND EXPERIMENT
    GARTH, JC
    WOOLF, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (06) : 1551 - 1556
  • [29] MONTE-CARLO TREATMENT OF MULTIPLE COULOMB SCATTERING IN PION-BEAM DOSE CALCULATIONS
    HAMM, RN
    WRIGHT, HA
    TURNER, JE
    JOURNAL OF APPLIED PHYSICS, 1975, 46 (10) : 4445 - 4452
  • [30] Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations
    Davidson, Scott E.
    Cui, Jing
    Kry, Stephen
    Deasy, Joseph O.
    Ibbott, Geoffrey S.
    Vicic, Milos
    White, R. Allen
    Followill, David S.
    MEDICAL PHYSICS, 2016, 43 (08) : 4842 - 4853