Dose calculations with the BEAM Monte Carlo code at extended SSD's

被引:0
|
作者
Stathakis, S [1 ]
Kappas, C [1 ]
Papanikolaou, N [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26500, Hellas, Greece
关键词
extended SSD; Monte Carlo; dose calculation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Extended surface to Skin Distance (SSD) beam data are very useful For hemibody and total body irradiation. Monte Carlo simulation provides an alternative mechanism to calculate the dose fur such treatment modalities. Comparison of the Monte Carlo results has been done with measured data of two linear accelerators of 6 MV, with results from two commercial 3D treatment-planning systems and with extrapolated data from measurements at 100 cm SSD. The results from the Monte Carlo simulations agreed with the experimental results within 1% and the PDD curves produced from the TPS's were within 2% error. The extrapolated PDD curves had a deviation of about 2%. It was found that d(max) migrated towards the surface with increasing SSD which was predicted by the simulations. Also, the mean photon energy as computed hy the simulation was found to be higher at extended SSD which is part of the reason why the PDDs are more penetrating for extended distances.
引用
收藏
页码:1679 / 1680
页数:2
相关论文
共 50 条
  • [1] Dosimetry of Electron Beams at Extremely Extended SSD: Monte Carlo Calculations and Measurements
    Xu, W.
    Zhang, R.
    Xu, M.
    Roeske, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Experimental validation of the DPM Monte Carlo code for photon beam dose calculations in inhomogeneous media
    Chetty, I
    Charland, P
    Tyagi, N
    McShan, D
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1351 - 1351
  • [3] Photon beam description in PEREGRINE for Monte Carlo dose calculations
    Cox, LJ
    vonWittenau, AES
    Bergstrom, PM
    Mohan, R
    Libby, B
    Wu, Q
    Lovelock, DMJ
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 142 - 145
  • [4] Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy
    Fix, MK
    Keller, H
    Rüegsegger, P
    Born, EJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2739 - 2747
  • [5] Parallelizing a powerful Monte Carlo method for electron beam dose calculations
    Volken, W
    Schwab, P
    Neuenschwander, H
    Kropf, PG
    CONCURRENCY-PRACTICE AND EXPERIENCE, 1996, 8 (06): : 489 - 498
  • [6] Retrospective Monte Carlo dose calculations with limited beam weight information
    Lindsay, Patricia E.
    El Naqa, Issam
    Hope, Andrew J.
    Vicic, Milos
    Cui, Jing
    Bradley, Jeffrey D.
    Deasy, Joseph O.
    MEDICAL PHYSICS, 2007, 34 (01) : 334 - 346
  • [8] A MACRO MONTE-CARLO METHOD FOR ELECTRON-BEAM DOSE CALCULATIONS
    NEUENSCHWANDER, H
    BORN, EJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01): : 107 - 125
  • [9] Comparative Study of Dose Calculations Using the BrainLAB Pencil Beam and Monte Carlo Dose Algorithms
    Ali, I.
    Algan, O.
    Thompson, S.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Validation of Monte Carlo dose planning calculations by epithermal beam: Dose distribution measurements in phantoms
    Carolan, MG
    Wallace, SA
    Allen, BJ
    Rosenfeld, AB
    Mathur, JN
    Meriaty, HA
    StecherRasmussen, F
    Moss, RL
    Raaijmakers, CPJ
    Konijnenberg, MW
    CANCER NEUTRON CAPTURE THERAPY, 1996, : 303 - 310