High resolution stroboscopic neutron radiography at the FRM-II ANTARES facility

被引:2
|
作者
Tremsin, Anton S. [1 ]
Muehlbauer, Martin J. [2 ]
Schillinger, Burkhard [2 ]
McPhate, Jason B. [1 ]
Vallerga, John V. [1 ]
Siegmund, Oswald H. W. [1 ]
Feller, W. Bruce [3 ]
机构
[1] Univ Calif Berkeley, Space Sci Lab, 7 Gauss Way, Berkeley, CA 94720 USA
[2] Tech Univ Munich, Forschungs Neutronenquelle FRM II, D-85747 Garching, Germany
[3] Nova Sci Inc, Sturbridge, MA 01566 USA
基金
美国国家科学基金会;
关键词
WATER DISTRIBUTION; DATA-ACQUISITION; COLD NEUTRON; TRANSMISSION; TOMOGRAPHY; EFFICIENCY; PROFILES; CHIP;
D O I
10.1109/NSSMIC.2009.5402458
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The rapidly developing field of high resolution neutron radiography primarily concentrates on non-destructive studies of stationary objects with relatively long exposure times required to achieve adequate neutron statistics. The combination of a high intensity neutron beam with a high temporal and spatial resolution detector, enables the investigation of dynamic processes in a stroboscopic mode, where image frames are synchronized with the sample or acquired continuously at high acquisition frame rates. Although neutron statistics in the acquisition frames as short as <10 mu s is considered quite low (typically <1000 n/cm(2) at the sample), repetitive processes can still be studied with high resolution by integrating a large number of frames synchronized to the process. In this paper we demonstrate the stroboscopic imaging capabilities of the highly collimated thermal neutron beamline ANTARES together with a high resolution detector with neutron sensitive microchannel plates and the Medipix2 readout. The dynamics of water uptake due to capillary forces as well as the two-phase flow of an air-water mixture is investigated, and stroboscopic imaging of an operating beam chopper and a spinning fan is performed, with sub-100 mu m spatial resolution and with acquisition frames varying between 10 mu s and 200 ms. The results of these experiments demonstrate the future potential for performing high resolution neutron radiography of fast and/or repetitive processes, such as water flow and uptake, operation of fuel injection nozzles, as well as many others.
引用
收藏
页码:4026 / +
页数:3
相关论文
共 50 条
  • [31] High intense positron beam at the new Munich research reactor FRM-II
    Hugenschmidt, C.
    Koegel, G.
    Schreckenbach, K.
    Sperr, P.
    Springer, M.
    Strasser, B.
    Triftshaeuser, W.
    Applied Surface Science, 1999, 149 (01): : 7 - 10
  • [32] Status of the high-flux backscattering spectrometer RSSM for the FRM-II reactor in Munich
    Kirstein, O
    Kozielewski, T
    Prager, M
    Richter, D
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S133 - S135
  • [33] High-resolution neutron powder diffractometer SPODI at research reactor FRM II
    Hoelzel, M.
    Senyshyn, A.
    Juenke, N.
    Boysen, H.
    Schmahl, W.
    Fuess, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 667 : 32 - 37
  • [34] Measurement of neutron flux and beam divergence at the cold neutron guide system of the new Munich research reactor FRM-II
    Zeitelhack, K
    Schanzer, C
    Kastenmüller, A
    Röhrmoser, A
    Daniel, C
    Franke, J
    Gutsmiedl, E
    Kudryashov, V
    Maier, D
    Päthe, D
    Petry, W
    Schöffel, T
    Schreckenbach, K
    Urban, A
    Wildgruber, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02): : 444 - 453
  • [35] Observation of the Filling Level of the FRM II Cold Source by Pinhole Neutron Radiography
    Schillinger, B.
    Calzada, E.
    Mueller, C.
    NEUTRON RADIOGRAPHY, 2008, : 487 - 492
  • [36] Germany's Garching FRM-II high-flux neutron research reactor goes into operation for the first time.
    不详
    NUCLEAR ENERGY-JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 2004, 43 (03): : 130 - 130
  • [37] Horizontal ToF-neutron reflectometer REFSANS at FRM-II Munich/Germany:: First tests and status
    Kampmann, R.
    Haese-Seiller, M.
    Kudryashov, V.
    Nickel, B.
    Daniel, C.
    Fenzl, W.
    Schreyer, A.
    Sackmann, E.
    Raedler, J.
    PHYSICA B-CONDENSED MATTER, 2006, 385-86 (1161-1163) : 1161 - 1163
  • [38] Shielding design for the PANDA spectrometer at the Munich high-flux reactor FRM-II
    Noack, K
    Pyka, NM
    Rogov, A
    Steichele, E
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 262 - 267
  • [39] Status of the high-flux backscattering spectrometer RSSM for the FRM-II reactor in Munich
    O. Kirstein
    T. Kozielewski
    M. Prager
    D. Richter
    Applied Physics A, 2002, 74 : s133 - s135
  • [40] On the construction of a new instrument for cold-neutron prompt gamma-ray activation analysis at the FRM-II
    Kudejová, P
    Materna, T
    Jolie, J
    Türler, A
    Wilk, P
    Baechler, S
    Kasztovszky, Z
    Révay, Z
    Belgya, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (02) : 221 - 227