Comparison of erythrocyte sedimentation rate measurement by the automated SEDIsystem™ and conventional Westergren method using the Bland and Altman statistical method

被引:15
|
作者
AlFadhli, SM [1 ]
Al-Awadhi, AM [1 ]
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Med Lab Sci, Sulibikhat 90805, Kuwait
关键词
erythrocyte sedimentation rate; SEDIsystem (TM); Westergren method;
D O I
10.1159/000085742
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the performance of SEDIsystemTM, a fully automated analyzer for the measurement of the erythrocyte sedimentation rate ( ESR), with the manual Westergren method. Materials and Methods: Both methods were applied to 150 randomly selected subjects. The linear regression and Bland and Altman data analysis methods were used to measure the agreement between the automated and manual methods. Results: The regression analysis showed a good correlation between the two methods ( r = 0.91). The Bland and Altman data analysis showed no systematic bias ( 95% confidence interval for mean difference); however, limits of agreement were between 11.52 and - 37.88. This indicates that ESR values measured by the SEDIsystem may be 11.52 mm/ h above or 37.88 mm/ h below the reference method. A greater scatter of data was also observed with abnormally high ( 1 25 mm/ h) ESR results ( mean of difference = - 21.4 and limits of agreement = - 45.2 and 2.26) compared with normal ( < 25 mm/ h) readings ( mean of difference = - 3.9 and limits of agreement = - 13.5 and 5.7). Conclusion: The Bland and Altman statistical analysis showed a wide degree of scatter between results obtained by the two ESR techniques that was not clearly demonstrated using the linear regression analysis. The automated system was found to underestimate ESR with the Bland and Altman statistical analysis, and therefore a correction factor is recommended. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 50 条
  • [31] Simultaneous measurement method of erythrocyte sedimentation rate and erythrocyte deformability in resource-limited settings
    Kang, Yang Jun
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [32] Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions
    Happe, MR
    Battafarano, DF
    Dooley, DP
    Rennie, TA
    Murphy, FT
    Casey, TJ
    Ward, JA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2002, 118 (01) : 14 - 17
  • [33] A NEW BIOELECTRICAL-IMPEDANCE METHOD FOR MEASUREMENT OF THE ERYTHROCYTE SEDIMENTATION-RATE
    CHA, K
    BROWN, EF
    WILMORE, DW
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 (04) : 499 - 508
  • [34] A NOVEL ALTERNATE METHOD FOR ERYTHROCYTE SEDIMENTATION RATE MEASUREMENT INTEGRATED INTO A HEMATOLOGY ANALYZER
    Qiu, Jun
    Liu, Dongmei
    Shen, Yimin
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 142 - 142
  • [35] Validation of the Diesse Mini-ves automated system using the Westergren erythrocyte sedimentation rate in patients with systemic inflammatory conditions.
    Happe, MR
    Rennie, TA
    Murphy, FT
    Dooley, DP
    Battafarano, DF
    Casey, TJ
    ARTHRITIS AND RHEUMATISM, 2000, 43 (09): : S149 - S149
  • [36] MEASUREMENT OF SEDIMENTATION-RATE USING AN ULTRASOUND METHOD
    CATHIGNOL, D
    FOURCADE, C
    NOUVELLE PRESSE MEDICALE, 1974, 3 (16): : 1033 - 1033
  • [37] CAUSE OF ANOMALOUS RESULTS IN THE ERYTHROCYTE SEDIMENTATION RATE USING WINTROBES METHOD
    SHANNON, FT
    BYWATERS, EGL
    BRITISH MEDICAL JOURNAL, 1957, 2 (DEC14): : 1405 - 1409
  • [38] Performance evaluation of alternate ESR measurement method using BC-780 automated hematology analyzer: a comparison study with the Westergren reference method
    Prompetchara, Eakachai
    Parnsamut, Chalisa
    Wangviwat, Nathawit
    Pitakpolrat, Patrawadee
    Chaiwong, Kwanlada
    Limpornpukdee, Orakarn
    Tanticharoenkarn, Surapat
    Ketloy, Chutitorn
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (02) : 303 - 311
  • [39] EVALUATION OF SEALED VACUUM EXTRACTION METHOD (SEDITAINER) FOR MEASUREMENT OF ERYTHROCYTE SEDIMENTATION-RATE
    PATTON, WN
    MEYER, PJ
    STUART, J
    JOURNAL OF CLINICAL PATHOLOGY, 1989, 42 (03) : 313 - 317
  • [40] QUICK MEASUREMENT OF HEMATOCRIT AND ERYTHROCYTE SEDIMENTATION-RATE BY MEANS OF A DENSITY TRACKING METHOD
    SCHNEDITZ, D
    KENNER, T
    GALLASCH, E
    RAINER, F
    BLUT, 1987, 55 (03): : 153 - 163