Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging

被引:0
|
作者
Degirmenci, E. [1 ]
Eyuboglu, B. M. [1 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
关键词
Magnetic resonance; impedance; anisotropic conductivity; imaging; tomography;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic Resonance Electrical Impedance Tomography (MREIT) brings high resolution imaging of true conductivity distribution to reality. MREIT images are reconstructed based on measurements of current density distribution and a surface potential value, induced by an externally applied current flow. Since biological tissues may be anisotropic, isotropic conductivity assumption, as it is adopted in most of MREIT reconstruction algorithms, introduces reconstruction inaccuracy. In this study, a novel algorithm is proposed to reconstruct MREIT images of anisotropic conductivity. Relative values of anisotropic conductivity are reconstructed iteratively, using only measurement of current density distribution. By measuring a surface potential or a conductivity value, true values of anisotropic conductivity can be recovered. The technique is evaluated based on simulated measurements with and without additive noise. The results show that anisotropic and isotropic conductivity distributions can be reconstructed, successfully.
引用
收藏
页码:728 / 731
页数:4
相关论文
共 50 条
  • [31] Conductivity imaging of canine body using 3T magnetic resonance electrical impedance tomography (MREIT) system
    Kim, H. J.
    Kim, Y. T.
    Jeong, W. C.
    Minhas, A. S.
    Lim, C. Y.
    Park, H. M.
    Woo, E. J.
    SCIENTIA IRANICA, 2011, 18 (06) : 1505 - 1510
  • [32] A Simulation Study on Induced Current Magnetic Resonance Electrical Impedance Tomography of Anisotropic Brain Tissues
    Liu, Yang
    Dai, Songshi
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 75 - 77
  • [33] Reconstruction of apparent orthotropic conductivity tensor image using magnetic resonance electrical impedance tomography
    Sajib, Saurav Z. K.
    Kim, Ji Eun
    Jeong, Woo Chul
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    JOURNAL OF APPLIED PHYSICS, 2015, 117 (10)
  • [34] Ramp-Preserving Denoising for Conductivity Image Reconstruction in Magnetic Resonance Electrical Impedance Tomography
    Lee, Chang-Ock
    Jeon, Kiwan
    Ahn, Seonmin
    Kim, Hyung Joong
    Woo, Eung Je
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (07) : 2038 - 2050
  • [35] On Denoising Technology in Magnetic Resonance Electrical Impedance Tomography
    Xie, Jiaye
    Liu, Jijun
    PROCEEDINGS OF FIRST INTERNATIONAL CONFERENCE OF MODELLING AND SIMULATION, VOL III: MODELLING AND SIMULATION IN ELECTRONICS, COMPUTING, AND BIO-MEDICINE, 2008, : 346 - 351
  • [36] Feasibility of magnetic resonance electrical impedance tomography (MREIT) conductivity imaging to evaluate brain abscess lesion: In vivo canine model
    Oh, Tong In
    Jeong, Woo Chul
    McEwan, Alistair
    Park, Hee Myung
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 189 - 197
  • [37] Magnetic resonance electrical impedance tomography of the breast: A simulation study on basic imaging setup
    Lee, B. I.
    Oh, S. H.
    Kim, T. -S.
    Woo, E. J.
    Lee, S. Y.
    Kwon, O.
    Seo, J. K.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 4377 - 4380
  • [38] Noninvasive bioimpedance imaging by means of current reconstruction magnetic resonance electrical impedance tomography
    Gao, Nuo
    He, Bin
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 273 - 274
  • [39] IMAGING OF ELECTRODE MOVEMENT AND CONDUCTIVITY CHANGE IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Quan, Wan
    Dinh, Anh
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1033 - +
  • [40] Imaging of electrode movement and conductivity change in Electrical Impedance Tomography
    Gomez-Laberge, Camille
    Adler, Andy
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1029 - +