Heat pumps are seen as a highly efficient promising technology for space heating and cooling. Their efficiency has been widely studied for different types of heat pumps operating with various energy sources including air, ground, and water. However, different components of the heat pump need to be closely investigated to improve the performance of the system. This study surveys the effects of compressor cooling fan, to evaluate how a heat pump system behaves at different fan speeds. Refrigerant R134a has been used as a circulating fluid in the system. The results obtained from detailed experiments are analyzed to optimize the performance of the entire system using a compressor cooling fan, considering COP, P-h diagrams, efficiency, and thermodynamic properties. It is concluded that cooling the compressor has a remarkable effect on the thermodynamic state of refrigerant which leads to a positive influence not only on the compressor efficiency but also on the entire heat pump unit.
引用
收藏
页码:319 / 331
页数:13
相关论文
共 50 条
  • [31] The selection of volume ratio of two-stage rotary compressor and its effects on air-to-water heat pump with flash tank cycle
    Ko, Younghwan
    Park, Sangkyoung
    Jin, Simon
    Kim, Byungsoon
    Jeong, Ji Hwan
    APPLIED ENERGY, 2013, 104 : 187 - 196
  • [32] Experimental and numerical investigation on thermoelectric coolers for comparing air-to-water to air-to-air refrigerators
    Faraz Afshari
    Journal of Thermal Analysis and Calorimetry, 2021, 144 : 855 - 868
  • [33] Multi-objective optimal control of an air-to-water heat pump for residential heating
    Clara Verhelst
    David Degrauwe
    Filip Logist
    Jan Van Impe
    Lieve Helsen
    Building Simulation, 2012, 5 : 281 - 291
  • [34] Experimental study of gas engine driven air to water heat pump in cooling mode
    Elgendy, E.
    Schmidt, J.
    ENERGY, 2010, 35 (06) : 2461 - 2467
  • [35] Subcritical recuperative air-to-water heat pump with zeotropic mixtures: Comparative and performance assessment
    Wu, Jinxing
    Sun, Shoujun
    Song, Qinglu
    Wang, Dechang
    Sun, Dandan
    ENERGY REPORTS, 2022, 8 : 13682 - 13697
  • [36] System optimization and experimental research on air source heat pump water heater
    Zhang, J.
    Wang, R. Z.
    Wu, J. Y.
    APPLIED THERMAL ENGINEERING, 2007, 27 (5-6) : 1029 - 1035
  • [37] Experimental and numerical investigation on thermoelectric coolers for comparing air-to-water to air-to-air refrigerators
    Afshari, Faraz
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (03) : 855 - 868
  • [38] Performance analysis and operation optimization of air-to-water CO2 heat pump with phase change thermal storage
    Wang, Zhihua
    Li, Guichen
    Wang, Fenghao
    Liu, Zixuan
    Wang, Ming
    ENERGY AND BUILDINGS, 2020, 209
  • [39] Refrigerant mass distribution in an invertible air-to-water heat pump: effect of the airflow velocity
    Guzzardi, Costantino
    Azzolin, Marco
    Lazzarato, Sandro
    Del Col, Davide
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 138 : 180 - 196
  • [40] PART-LOAD PERFORMANCE ANALYSIS OF AIR-TO-WATER HEAT-PUMP SYSTEMS
    TASSOU, SA
    MARQUAND, CJ
    WILSON, DR
    JOURNAL OF THE INSTITUTE OF ENERGY, 1984, 57 (432): : 364 - 367