Anatomical and Imaging Study on the Optimum Entry Point and Trajectory for Anterior Transpedicular Root Screw Placement into the Lower Cervical Spine

被引:2
|
作者
Zhang, Jihui [1 ]
Zhao, Liujun [1 ]
Xu, Jingfei [2 ]
Gu, Yongjie [1 ]
Yu, Liang [1 ]
机构
[1] Ningbo No 6 Hosp, Dept Spinal Surg, Ningbo 315040, Zhejiang, Peoples R China
[2] Ningbo No 6 Hosp, Dept Med Insurance, Ningbo 315040, Zhejiang, Peoples R China
关键词
PEDICLE SCREW; PLATE FIXATION; FUSION; POSTERIOR; CORPECTOMY; EXTRUSION; ACCURACY; OUTCOMES; RISK;
D O I
10.1155/2022/8159570
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective. To study the optimum entry point and trajectory for anterior transpedicular root screw (ATPRS) placement into the lower cervical spine (LCS), so as to provide a basis for clinical application. Methods. A retrospective analysis of cervical CT images of patients who underwent cervical CT examination in the Spinal Surgery of Ningbo No. 6 Hospital from January 2020 to August 2021 was conducted. The data were obtained and modeled. On the coronal plane, the vertebral body (VB) between the anterior midline of cervical vertebral segments C3-7 and the left P line (by drawing the line parallel to the anterior midline of the VB at the intersection of the anterior edge of the Luschka's joint and the upper endplate) was equally divided into 9 zones (a-i). The ideal entry point and path of cervical ATPRS were designed and recorded. Additionally, 7 cadaveric specimens were selected, and the screw placement parameters were regenerated according to the above methods for screw placement. Results. Zone i of each segment, with the longest screw length, was the best area for screw placement. In all patients, the horizontal angles of vertebrae C3-7 in zones a, d, and g, zones b, e, and h, and zones c, f, and i showed a gradually decreasing trend. The sagittal angle range of C3-7 in all patients showed a gradually increasing trend in zones a-c, d-f, and g-i. The distance from the anterior midline of C3-7 to the P line increased in all patients, and the distance was longer in males than in females, with statistical significance. Pedicle screws were successfully inserted in all the 7 cadaveric specimens. Conclusions. ATPRS placement can be used for LCS internal fixation, and the precise screw placement parameters can be simulated by the software, which provides theoretical basis for its future clinical application.
引用
收藏
页数:7
相关论文
共 23 条
  • [21] Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study
    Fu, Sheng-Yu
    Liu, Huan
    Wang, Zhao-Rui
    Wang, Bang
    Li, Xing-Bin
    Huang, Ai-Bing
    EUROPEAN SPINE JOURNAL, 2022, 31 (12) : 3426 - 3432
  • [22] Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study
    Sheng-Yu Fu
    Huan Liu
    Zhao-Rui Wang
    Bang Wang
    Xing-Bin Li
    Ai-Bing Huang
    European Spine Journal, 2022, 31 : 3426 - 3432
  • [23] Coronal Multiplane Reconstructed Computed Tomography Image Determining Lateral Vertebral Notch-Referred Pedicle Screw Entry Point in Subaxial Cervical Spine: A Preclinical Study
    Wu, Chunyang
    Huang, Zhongren
    Pan, Zhimin
    Luo, Jiaquan
    Li, Zhiyun
    Zhong, Junlong
    Chen, Yiwei
    Han, Zhimin
    Abumi, Kuniyoshi
    Ha, Yoon
    Cao, Kai
    WORLD NEUROSURGERY, 2017, 103 : 322 - 329