Anatomical and Imaging Study on the Optimum Entry Point and Trajectory for Anterior Transpedicular Root Screw Placement into the Lower Cervical Spine

被引:2
|
作者
Zhang, Jihui [1 ]
Zhao, Liujun [1 ]
Xu, Jingfei [2 ]
Gu, Yongjie [1 ]
Yu, Liang [1 ]
机构
[1] Ningbo No 6 Hosp, Dept Spinal Surg, Ningbo 315040, Zhejiang, Peoples R China
[2] Ningbo No 6 Hosp, Dept Med Insurance, Ningbo 315040, Zhejiang, Peoples R China
关键词
PEDICLE SCREW; PLATE FIXATION; FUSION; POSTERIOR; CORPECTOMY; EXTRUSION; ACCURACY; OUTCOMES; RISK;
D O I
10.1155/2022/8159570
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective. To study the optimum entry point and trajectory for anterior transpedicular root screw (ATPRS) placement into the lower cervical spine (LCS), so as to provide a basis for clinical application. Methods. A retrospective analysis of cervical CT images of patients who underwent cervical CT examination in the Spinal Surgery of Ningbo No. 6 Hospital from January 2020 to August 2021 was conducted. The data were obtained and modeled. On the coronal plane, the vertebral body (VB) between the anterior midline of cervical vertebral segments C3-7 and the left P line (by drawing the line parallel to the anterior midline of the VB at the intersection of the anterior edge of the Luschka's joint and the upper endplate) was equally divided into 9 zones (a-i). The ideal entry point and path of cervical ATPRS were designed and recorded. Additionally, 7 cadaveric specimens were selected, and the screw placement parameters were regenerated according to the above methods for screw placement. Results. Zone i of each segment, with the longest screw length, was the best area for screw placement. In all patients, the horizontal angles of vertebrae C3-7 in zones a, d, and g, zones b, e, and h, and zones c, f, and i showed a gradually decreasing trend. The sagittal angle range of C3-7 in all patients showed a gradually increasing trend in zones a-c, d-f, and g-i. The distance from the anterior midline of C3-7 to the P line increased in all patients, and the distance was longer in males than in females, with statistical significance. Pedicle screws were successfully inserted in all the 7 cadaveric specimens. Conclusions. ATPRS placement can be used for LCS internal fixation, and the precise screw placement parameters can be simulated by the software, which provides theoretical basis for its future clinical application.
引用
收藏
页数:7
相关论文
共 23 条
  • [1] Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine
    Liujun Zhao
    Guoqing Li
    Jiayong Liu
    Gregory M. Benedict
    Nabil A. Ebraheim
    Weihu Ma
    Shaohua Sun
    Rongming Xu
    Chaoyue Ruan
    European Spine Journal, 2014, 23 : 2175 - 2181
  • [2] Radiological studies on the best entry point and trajectory of anterior cervical pedicle screw in the lower cervical spine
    Zhao, Liujun
    Li, Guoqing
    Liu, Jiayong
    Benedict, Gregory M.
    Ebraheim, Nabil A.
    Ma, Weihu
    Sun, Shaohua
    Xu, Rongming
    Ruan, Chaoyue
    EUROPEAN SPINE JOURNAL, 2014, 23 (10) : 2175 - 2181
  • [3] Measurement of anatomical parameters of anterior transpedicular root screw intervertebral fusion system of cervical spine
    Ye, Sen-qi
    Zhao, Liu-jun
    Hou, Zhi-peng
    Zhang, Ji-hui
    Yu, Liang
    Gu, Yong-jie
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [4] Measurement of anatomical parameters of anterior transpedicular root screw intervertebral fusion system of cervical spine
    Sen-qi Ye
    Liu-jun Zhao
    Zhi-peng Hou
    Ji-hui Zhang
    Liang Yu
    Yong-jie Gu
    BMC Musculoskeletal Disorders, 24
  • [5] Progress of the Anterior Transpedicular Screw in Lower Cervical Spine: A Review
    Zhang, Yuan-Wei
    Zeng, Ting
    Gao, Wen-Cheng
    Xiao, Xin
    Xiao, Yan
    Chen, Xi
    Zhang, Su-Li
    Deng, Liang
    MEDICAL SCIENCE MONITOR, 2019, 25 : 6281 - 6290
  • [6] Biomechanical study of anterior transpedicular root screw intervertebral fusion system of lower cervical spine: a finite element analysis
    Ye, Senqi
    Ye, Jiachun
    Hou, Zhipeng
    You, Xinmao
    Shen, Shufeng
    Zhang, Jihui
    Yu, Liang
    Gu, Yongjie
    Wang, Wei
    Zhao, Liujun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [7] A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study
    Wu, Weidong
    Chen, Chun
    Ning, Jinpei
    Sun, Peidong
    Zhang, Jinyuan
    Wu, Changfu
    Bi, Zhenyu
    Fan, Jihong
    Lai, Xianliang
    Ouyang, Jun
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (06):
  • [8] Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study
    Li, Jie
    Gan, Kaifeng
    Chen, Binhui
    Chen, Yilei
    Hong, Jinjiong
    Bei, Dikai
    Fan, Tengdi
    Zheng, Minzhe
    Zhao, Liujun
    Zhao, Fengdong
    MEDICINE, 2022, 101 (29) : E29316
  • [9] Three-dimensional finite element study of anterior transpedicular screw-artificial vertebral fixation in lower cervical spine
    Weidong Wu
    Peidong Sun
    Chun Chen
    Changfu Wu
    Jun Ouyang
    医用生物力学, 2013, 28(S1) (S1) : 125 - 126
  • [10] The Study on Comparison of 3 Techniques for Transarticular Screw Placement in the Lower Cervical Spine
    Zhao, Liujun
    Xu, Rongming
    Liu, Jiayong
    Sochacki, Kyle R.
    Ma, Weihu
    Jiang, Weiyu
    Liu, Guanyi
    Cao, Jin
    Hua, Qun
    SPINE, 2012, 37 (08) : E468 - E472