Bioengineering reasons for the failure of metal-on-metal hip prostheses AN ENGINEER'S PERSPECTIVE

被引:61
|
作者
Fisher, J. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
来源
基金
英国工程与自然科学研究理事会;
关键词
WEAR DEBRIS; CUP ANGLE; MICROSEPARATION; REPLACEMENTS; BEARINGS; FRICTION; LUBRICATION;
D O I
10.1302/0301-620X.93B8.26936
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Bioengineering reasons for increased wear and failure of metal-on-metal (MoM) bearings in hip prostheses have been described. Low wear occurs in MoM hips when the centre of the femoral head is concentric with the centre of the acetabular component and the implants are correctly positioned. Translational or rotational malpositioning of the components can lead to the contact-patch of the femoral component being displaced to the rim of the acetabular component, resulting in a ten- to 100-fold increase in wear and metal ion levels. This may cause adverse tissue reactions, loosening of components and failure of the prosthesis.
引用
下载
收藏
页码:1001 / 1004
页数:4
相关论文
共 50 条
  • [1] Metal-on-metal pairs for hip prostheses
    Plitz, W
    Veihelmann, A
    Pellengahr, C
    ORTHOPADE, 2003, 32 (01): : 17 - 22
  • [2] Imaging of Metal-on-Metal Hip Prostheses
    Squire, Matthew W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 556 - 557
  • [3] MR Imaging of Metal-on-Metal Hip Prostheses
    Campe, Carson B.
    Palmer, William E.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2013, 21 (01) : 155 - +
  • [4] The wear pattern in metal-on-metal hip prostheses
    Anissian, HL
    Stark, A
    Good, V
    Dahlstrand, H
    Clarke, IC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (06): : 673 - 678
  • [5] A Lexicon for Wear of Metal-on-Metal Hip Prostheses
    McKellop, Harry A.
    Hart, Alister
    Park, Sang-Hyun
    Hothi, Harry
    Campbell, Pat
    Skinner, John A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (09) : 1221 - 1233
  • [6] Wear of surface engineered metal-on-metal hip prostheses
    J. Fisher
    X. Q. Hu
    T. D. Stewart
    S. Williams
    J. L. Tipper
    E. Ingham
    M. H. Stone
    C. Davies
    P. Hatto
    J. Bolton
    M. Riley
    C. Hardaker
    G. H. Isaac
    G. Berry
    Journal of Materials Science: Materials in Medicine, 2004, 15 : 225 - 235
  • [7] Metal-on-metal hip prostheses: where are we now?
    Wilkinson, J. Mark
    BRITISH MEDICAL JOURNAL, 2012, 345
  • [8] Wear of surface engineered metal-on-metal hip prostheses
    Fisher, J
    Hu, XQ
    Stewart, TD
    Williams, S
    Tipper, JL
    Ingham, E
    Stone, MH
    Davies, C
    Hatto, P
    Bolton, J
    Riley, M
    Hardaker, C
    Isaac, GH
    Berry, G
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) : 225 - 235
  • [9] The wear of metal-on-metal total hip prostheses measured in a hip simulator
    Scholes, SC
    Green, SM
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H6) : 523 - 530
  • [10] Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
    Firkins, P.J.
    Tipper, J.L.
    Ingham, E.
    Stone, M.H.
    Farrar, R.
    Fisher, J.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001, 215 (01) : 119 - 122