Analysis of anti-HIV nucleoside inhibitors by capillary electrophoresis-electrospray ionization mass spectrometry

被引:18
|
作者
Agrofolio, LA [1 ]
Cahours, X
Tran, TT
Dessans, H
Kieda, C
Morin, P
机构
[1] CNRS, Fac Sci, ICOA, UMR 6005, F-45100 Orleans, France
[2] CNRS, CBM, UPR 4301, F-45100 Orleans, France
来源
关键词
D O I
10.1081/NCN-100002309
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method employing capillary electrophoresis (CE) with tandem mass spectrometry (MS) has been developed for the simultaneous determination, on one hand, of zidovudine (AZT) with stavudine (d4T), and on the other hand, of lamivudine (3TC) with a didanosine metabolite (ddA), four potent human immunodeficiency virus reverse transcriptase (RT-HIV) inhibitors. The influence of several parameters (pH and ionic strength of volatile formic acid-ammonia buffer) as well as the influence of magnesium cation upon electroosmotic flow, electrophoretic mobility and peak efficiency has been studied. The limit of detection (LOD) by this method is 2.5 ppb for AZT and 20 ppb for d4T, 2 ppb for ddA and 5 ppb for 3TC, respectively. This paper illustrates the current importance in CE-ESI/MS/MS technique as a complementary or substituted method to measure levels (at ng/mL) of anti-HIV drugs alone or in combination.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 50 条
  • [21] Determination of Isoflavones in Legumes by QuEChERS-Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry
    Perez-Martin, Lara
    Bustamante-Rangel, Myriam
    Milagros Delgado-Zamarreno, Maria
    CURRENT ANALYTICAL CHEMISTRY, 2015, 11 (02) : 117 - 123
  • [22] Comparison of sheathless and sheath-flow electrospray interfaces for the capillary electrophoresis-electrospray ionization-mass spectrometry analysis of peptides
    Sanz-Nebot, V
    Balaguer, E
    Benavente, F
    Barbosa, J
    ELECTROPHORESIS, 2005, 26 (7-8) : 1457 - 1465
  • [23] On-line capillary electrophoresis-electrospray ionization mass spectrometry using a polymerized anionic surfactant
    Lu, WZ
    Shamsi, SA
    McCarley, TD
    Warner, IM
    ELECTROPHORESIS, 1998, 19 (12) : 2193 - 2199
  • [24] Positional and geometrical anionic isomer separations by capillary electrophoresis-electrospray ionization-mass spectrometry
    Nogami, C
    Sawada, H
    ELECTROPHORESIS, 2005, 26 (7-8) : 1406 - 1411
  • [25] Evaluation of the electrophoretic behaviour of opioid peptides -: Separation by capillary electrophoresis-electrospray ionization mass spectrometry
    Sanz-Nebot, Victoria
    Benavente, Fernando
    Hernandez, Elena
    Barbosa, Jose
    ANALYTICA CHIMICA ACTA, 2006, 577 (01) : 68 - 76
  • [26] A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides
    Ullsten, S
    Zuberovic, A
    Wetterhall, M
    Hardenborg, E
    Markides, KE
    Bergquist, J
    ELECTROPHORESIS, 2004, 25 (13) : 2090 - 2099
  • [27] Microchip capillary electrophoresis-electrospray ionization mass spectrometry analysis of paracetamol metabolites in human urine: An intriguing case
    Lentini, Giovanni
    Habtemariam, Solomon
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1327 : 160 - 160
  • [28] DETERMINATION OF AMINO-ACIDS BY ONLINE CAPILLARY ELECTROPHORESIS-ELECTROSPRAY IONIZATION MASS-SPECTROMETRY
    LU, W
    YANG, G
    COLE, RB
    ELECTROPHORESIS, 1995, 16 (04) : 487 - 492
  • [29] Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments
    Bonvin, Gregoire
    Schappler, Julie
    Rudaz, Serge
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 : 17 - 31
  • [30] A beveled tip sheath liquid interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tseng, MC
    Chen, YR
    Her, GR
    ELECTROPHORESIS, 2004, 25 (13) : 2084 - 2089