Mitral valve replacement with mechanical prostheses in children: improved operative risk and survival

被引:49
|
作者
Alexiou, C
Galogavrou, M
Chen, Q
McDonald, A
Salmon, AP
Keeton, BK
Haw, MP
Monro, JL
机构
[1] Gen Hosp, Dept Cardiac Surg, Southampton SO16 6YD, Hants, England
[2] Gen Hosp, Dept Paediat Cardiol, Southampton SO16 6YD, Hants, England
关键词
mechanical mitral valve; children;
D O I
10.1016/S1010-7940(01)00763-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The purpose of this study was to assess the early and late outcome following mitral valve replacement (MVR) with mechanical prostheses in children. Patients and methods: Between 1981 and 2000, 44 consecutive children (mean age 6.8 +/- 4.7 years, 2 months-16 years) underwent mechanical MVR in Southampton. Twenty-three children were less than 5-years-old and nine were infants. Disease aetiology was congenital in 37, rheumatic in four, infective in two and Marfan's syndrome in one. Mitral regurgitation was present in 36 and mitral stenosis in eight. Concomitant procedures were performed in 13, including aortic valve replacement (AVR) in seven. Follow-up was complete (mean 6.4 +/- 4.8 years, 1 month-18.1 years). Results: The overall operative mortality was 14% (six patients). Before and after 1990 operative mortality was 31 vs 3.6% (P = 0.02). From 1990, operative mortality for infants was zero out of six, for children less than 5-years-old was one out of 16 (one death after emergency AVR and MVR) and for older children it was 0/12. Seven children experienced valve or anticoagulation treatment-related events and eight had a mitral valve re-operation. Ten-year freedom from thromboembolism, prosthetic valve infection, bleeding, paravalvular leak and a mitral valve re-operation was 92.8 + 5.2, 97.3 +/- 2.7, 97.7 +/- 2.3, 97.2 +/- 2.7 and 75 +/- 9.7%, respectively, Overall 10-year survival was 78 +/- 7% (four late deaths); for children under vs over 5 years it was 61 +/- 11 vs 95.2 +/- 4.6% (P = 0.02), for atrio-ventricular septal defect (AVSD) vs other pathology 55 +/- 15 vs 89 +/- 6.1% (P = 0.05) and for those operated before 1990 vs after 1990 it was 63 +/- 8.1 vs 86 +/- 8.2% (P = 0.04). Conclusions: Mechanical MVR, in the current era, carries a low operative risk across the spectrum of paediatric age. Late survival is better for older children and those having no-AVSD pathology but it has improved substantially during the 1990s irrespective of age and disease aetiology. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 50 条
  • [31] AN IMPROVED DISC VALVE FOR MITRAL REPLACEMENT
    TABER, RE
    IMAI, Y
    KOUNO, N
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1970, 16 : 224 - &
  • [32] Outcomes and associated risk factors for mitral valve replacement in children
    Alsoufi, Bahaaldin
    Manlhiot, Cedric
    Al-Ahmadi, Mamdouh
    McCrindle, Brian W.
    Kalloghlian, Avedis
    Siblini, Ghassan
    Bulbul, Ziad
    Al-Halees, Zohair
    Fragata, J.
    Hosseinpour, R.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (03) : 543 - 551
  • [33] Results of valve replacement with Omniscience mechanical prostheses
    Edwards, MS
    Russell, GB
    Edwards, AF
    Hammon, JW
    Cordell, AR
    Kon, ND
    ANNALS OF THORACIC SURGERY, 2002, 74 (03): : 665 - 670
  • [34] Pulmonary valve replacement: A role for mechanical prostheses?
    Rosti, L
    Murzi, B
    Colli, AM
    Festa, P
    Redaelli, S
    Frigiola, A
    ANNALS OF THORACIC SURGERY, 1998, 65 (03): : 889 - 890
  • [35] DETERMINANTS OF OPERATIVE SURVIVAL FOLLOWING COMBINED MITRAL-VALVE REPLACEMENT AND CORONARY REVASCULARIZATION
    DISESA, VJ
    COHN, LH
    COLLINS, JJ
    KOSTER, JK
    VANDEVANTER, S
    ANNALS OF THORACIC SURGERY, 1982, 34 (05): : 482 - 489
  • [36] REVIEW OF RE-OPERATIVE SURGICAL MITRAL VALVE REPLACEMENT VERSUS TRANSCATHETER MITRAL VALVE-IN-VALVE REPLACEMENT
    Sengupta, Aditya
    Yazdchi, Farhang
    Premkumar, Akash
    Percy, Edward
    Hirji, Sameer
    Shekar, Prem S.
    Kaneko, Tsuyoshi
    Tang, Gilbert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1212 - 1212
  • [37] Bileaflet mechanical prostheses in mitral and multiple valve replacement surgery - Influence of anticoagulant management on performance
    Jamieson, WRE
    Miyagishima, RT
    Tyers, GFO
    Lichenstein, SV
    Munro, AI
    Burr, LH
    CIRCULATION, 1997, 96 (09) : 134 - 139
  • [38] REDUCTION OF THE OPERATIVE RISK FOR REOPERATIONS ON VALVE PROSTHESES
    PERIER, P
    SWANSON, J
    TAKRITI, A
    CHACHQUES, JC
    FABIANI, JN
    DELOCHE, A
    CHAUVAUD, S
    DREYFUS, G
    RELLAND, J
    BLONDEAU, P
    DALLAINES, C
    CARPENTIER, A
    ANNALES DE CHIRURGIE, 1987, 41 (02): : 126 - 129
  • [39] Cardiac Reoperation or Transcatheter Mitral Valve Replacement for Patients With Failed Mitral Prostheses
    Ueyama, Hiroki A.
    Miyamoto, Yoshihisa
    Watanabe, Atsuyuki
    Gotanda, Hiroshi
    Lerakis, Stamatios
    Latib, Azeem
    Kaneko, Tsuyoshi
    Kuno, Toshiki
    Tsugawa, Yusuke
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (02) : 317 - 330
  • [40] Survival After Mitral Valve Replacement for Leaflet Escape in a Contemporary On-X Mechanical Valve
    Amoros Rivera, Carlos
    Lopez Rodriguez, Francisco Javier
    Arnaiz Garcia, Maria Elena
    Arevalo Abascal, Ramon Adolfo
    Barral Varela, Ana Maria
    Lopez Tatis, Myriel Mayelinne
    Sastre, Jose A.
    Lozano Sanchez, Francisco
    Torres Hernandez, Jose Angel
    Gonzalez Santos, Jose Maria
    ANNALS OF THORACIC SURGERY, 2019, 108 (05): : E307 - E309