Region-of-interest image reconstruction in circular cone-beam microCT

被引:23
|
作者
Cho, Seungryong [1 ,2 ]
Bian, Junguo [1 ]
Pelizzari, Charles A. [2 ]
Chen, Chin-Tu [1 ]
He, Tong-Chuan [3 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[3] Univ Chicago, Dept Surg, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1118/1.2804924
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone-beam microcomputed tomography (microCT) is one of the most popular choices for small animal imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest (ROI) imaging techniques in CT, which can reconstruct an ROI image from the projection data set of the ROI, can be used not only for reducing imaging-radiation exposure to the subject and scatters to the detector but also for potentially increasing spatial resolution of the reconstructed images. Increasing spatial resolution in microCT images can facilitate improved accuracy in many assessment tasks. A method proposed previously for increasing CT image spatial resolution entails the exploitation of the geometric magnification in cone-beam CT. Due to finite detector size, however, this method can lead to data truncation for a large geometric magnification. The Feldkamp-Davis-Kress (FDK) algorithm yields images with artifacts when truncated data are used, whereas the recently developed backprojection filtration (BPF) algorithm is capable of reconstructing ROI images without truncation artifacts from truncated cone-beam data. We apply the BPF algorithm to reconstructing ROI images from truncated data of three different objects acquired by our circular cone-beam microCT system. Reconstructed images by use of the FDK and BPF algorithms from both truncated and nontruncated cone-beam data are compared. The results of the experimental studies demonstrate that, from certain truncated data, the BPF algorithm can reconstruct ROI images with quality comparable to that reconstructed from nontruncated data. In contrast, the FDK algorithm yields ROI images with truncation artifacts. Therefore, an implication of the studies is that, when truncated data are acquired with a configuration of a large geometric magnification, the BPF algorithm can be used for effective enhancement of the spatial resolution of a ROI image. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:4923 / 4933
页数:11
相关论文
共 50 条
  • [31] Analysis of image noise with exact cone-beam reconstruction
    Lee, SW
    Wang, G
    RADIOLOGY, 2002, 225 : 253 - 253
  • [32] Local cone-beam tomography image reconstruction on chords
    Anastasio, Mark A.
    Zou, Yu
    Sidky, Emil Y.
    Pan, Xiaochuan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (06) : 1569 - 1579
  • [33] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [34] Cone-beam local tomography image reconstruction on chords
    Anastasio, Mark A.
    Sidky, E. Y.
    Zou, Y.
    Pan, X.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [35] Cone-Beam CT Image Reconstruction with Spherical Harmonics
    Shimomura, T.
    Haga, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E391 - E392
  • [36] Fast image reconstruction with cone-beam ART algorithm
    Zhang, Shunli
    Zhang, Dinghua
    Huang, Kuidong
    Cheng, Yunyong
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (04): : 887 - 892
  • [37] Cone-beam image reconstruction using spherical harmonics
    Taguchi, K
    Zeng, GSL
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : N127 - N138
  • [38] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [39] Projection extension for region of interest imaging in cone-beam CT
    Wiegert, J
    Bertram, M
    Netsch, T
    Wulff, J
    Weese, J
    Rose, G
    ACADEMIC RADIOLOGY, 2005, 12 (08) : 1010 - 1023
  • [40] Automated Geometric Calibration and Reconstruction in Circular Cone-Beam Tomography
    Mennessier, C.
    Clackdoyle, R.