Er,Cr:YSGG Laser Surface Modification Effect on Dentin Bonding to Zirconia: An In Vitro Study

被引:4
|
作者
Chemaly, Nancy [1 ,2 ,8 ]
Franzen, Rene [2 ]
Daou, Maha [3 ]
Karam, Mia [4 ,5 ]
Mhanna, Rami [5 ]
Kozlova, Yuliya [6 ]
Habre, Pascale [7 ]
机构
[1] St Joseph Univ, Fac Dent Med, Dept Removable Prosthodont, Beirut, Lebanon
[2] Rhein Westfal TH Aachen, Dept Operat Dent, Aachen, Germany
[3] St Joseph Univ, Fac Dent Med, Dept Pediat Dent, Beirut, Lebanon
[4] Amer Univ Beirut, Fac Med, Dept Biochem & Mol Genet, Beirut, Lebanon
[5] Amer Univ Beirut, Maroun Semaan Fac Engn & Architecture, Biomed Engn Program, Beirut, Lebanon
[6] PeoplesFriendship Univ Russia, Med Inst, Dept Propaedeut Dent Dis, Moscow, Russia
[7] St Joseph Univ, Fac Dent Med, Dept Fixed Prosthodont, Beirut, Lebanon
[8] St Joseph Univ, Fac Dent Med, Dept Removable Prosthodont, Beirut, Lebanon
关键词
zirconia; Er; Cr:YSGG; glass ionomer; resin; shear bond strength; RESIN CEMENT; AIR-ABRASION; ERYAG LASER; STRENGTH; RETENTION; ENAMEL; ROUGHNESS; AGENTS;
D O I
10.1089/photob.2022.0015
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study investigated the effect of dentin surface treatment with the erbium, chromium-doped yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser on the bond strength of zirconia to dentin. Background data: Although it is well-known that resin cement (RC) provides adequate bond strength of zirconia restorations to the tooth structure, many clinicians were not convinced in bonding reliability to zirconia materials. So, they preferred cementing their crowns with glass-ionomer cement (GIC). Pretreating the dentin surface is recommended to improve the adhesion of crowns cemented with GIC or RC. Recently, the Er,Cr:YSGG laser has been widely used for a cavity preparation, conditioning the tooth structure. However, there is not enough research on the bond strength of zirconia crowns cemented on a Er,Cr:YSGG laser-treated dentin. Methods: Forty-eight molars were cut horizontally at the crest of curvature. The flat dentin surface of 24 molars was left untreated, whereas the dentin surface of the other half was treated using an Er,Cr:YSGG laser 2.78 mu m (4.5 W, 8.18 J/cm(2), 90 mJ, 60 mu s, 50 Hz, 60% air and 80% water). In addition, 48 plates of zirconia were prepared to be cemented with GIC or RC on the dentin surface. So, the molars were divided into four groups as follows: GIC+untreated dentin; GIC+treated dentin; RC+untreated dentin; and RC+treated dentin. All the specimens were subjected to shear bond strength test. The mode of failure was determined and additional samples were prepared to evaluate the cement-dentin interface using a scanning electron microscope. Data were analyzed with two-way analysis of variance accompanied by univariate analyses. Results: The bond strength of zirconia cemented with GIC or bonded with RC significantly increased on a Er,Cr:YSGG laser-treated dentin surface (p < 0.05). Conclusions: Dentin preconditioning with an Er,Cr:YSGG laser significantly improved the bond strength of zirconia plates to dentin as compared with untreated dentin.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [21] Effect of an Er,Cr:YSGG laser preparation on dentin bond strength of a universal adhesive
    Yazici, A. Ruya
    Karaman, Emel
    Tuncer, Duygu
    Berk, Gizem
    Ertan, Atilla
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2016, 30 (22) : 2477 - 2484
  • [22] Effects of Er,Cr:YSGG laser irradiation on the surface characteristics of titanium discs: An in vitro study
    Esra Ercan
    Tuna Arin
    Levent Kara
    Celal Çandirli
    Cihan Uysal
    Lasers in Medical Science, 2014, 29 : 875 - 880
  • [23] Effects of Er,Cr:YSGG laser irradiation on the surface characteristics of titanium discs: An in vitro study
    Ercan, Esra
    Arin, Tuna
    Kara, Levent
    Candirli, Celal
    Uysal, Cihan
    LASERS IN MEDICAL SCIENCE, 2014, 29 (03) : 875 - 880
  • [24] A study on acquired acid resistance of enamel and dentin irradiated by Er,Cr:YSGG laser
    Hossain, M
    Kimura, Y
    Nakamura, Y
    Yamada, Y
    Kinoshita, J
    Matsumoto, K
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2001, 19 (03): : 159 - 163
  • [25] The Er,Cr:YSGG laser in endodontics -: Results of an in-vitro study
    Schoop, U
    Kluger, W
    Moritz, A
    Sperr, W
    LASERS IN SURGERY AND MEDICINE, 2002, : 16 - 16
  • [26] Influence of different surface protocols on dentin bond strength irradiated with Er,Cr:YSGG laser
    Valinhos Piccioni M.A.R.
    Girotto A.C.
    Saad J.R.C.
    de Campos E.A.
    Lasers in Dental Science, 2019, 3 (1) : 43 - 51
  • [27] Effects of the Er, Cr:YSGG laser irradiation on dentin bond strength
    Piccioni, M. A. R. V.
    Neves, T. P. C.
    Kubo, C. S.
    Saad, J. R. C.
    Campos, E. A.
    LASER PHYSICS, 2016, 26 (02)
  • [28] Adhesion in dentin prepared with Er,Cr:YSGG laser: Systematic review
    Silva, Ana Catarina
    Melo, Paulo
    Ferreira, Joao Cardoso
    Oliveira, Teresa
    Gutknecht, Norbert
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (01) : 129 - 134
  • [30] Effects of Er:YAG and Er,Cr:YSGG laser irradiation on the adhesion to eroded dentin
    Ramos, Thaysa Monteiro
    Ramos-Oliveira, Thayanne Monteiro
    de Freitas, Patricia Moreira
    Azambuja, Nilton, Jr.
    Esteves-Oliveira, Marcella
    Gutknecht, Norbert
    Eduardo, Carlos de Paula
    LASERS IN MEDICAL SCIENCE, 2015, 30 (01) : 17 - 26